Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 18 of 18 for “"Continuous Glucose Monitoring System"”.
-
A Non-Enzymatic Continuous Glucose Monitoring System Using Electrochemical Impedance Spectroscopy
… is a feasibility trial for the development of a continuous glucose monitoring system using electrochemical impedance spectroscopy. Three separate experiments are conducted to determine the effects of electrode surface area on sensing efficacy, the effects of glucose concentration on impedimetric …
-
A Low-Power Wireless Transmitter for a Continuous Glucose Monitoring System-on-Chip
Continuous glucose monitoring (CGM) can improve diabetes management by providing frequent measurements and revealing trends that are difficult to capture with invasive, intermittent tests. To this end, a miniaturized, wearable sensing platform that operates continuously and delivers timely alerts …
-
Continuous glucose monitoring system : a new tool to assess blood glucose concentrations in cats with diabetes mellitus
… and adjust insulin therapy. Portable blood glucose meters (PBGM) were developed to improve glycemic control in diabetic humans and were validated for use in animals. In the last decade continuous glucose monitoring systems (CGMS) that measure glucose concentrations in the interstitial fluid …
-
An overview on contact allergy to acrylates /
… using home gel nail kits and people wearing continuous glucose monitoring system devices. 2-hydroxyethyl methacrylate (HEMA) is found to be the most common sensitizing agent and best screening marker with a positivity rate above 90% among sensitized subjects, while isobornyl acrylate (IBOA), …
-
Development of an Encapsulation Strategy for an Implantable Optical Glucose Sensing Technology Compatible with a Self-Cleaning Membrane
… complications accentuates the urgency for continuous glucose monitoring. Optical techniques, especially fluorescence-affinity assays, offer a strategy that transcends current transcutaneous sensors by enabling subcutaneous implantation and interrogation. Biosensors can initiate an immune …
-
Mechanisms of axonal dysfunction in diabetes mellitus
… incipient neuropathy and possibly as a means of monitoring treatment efficacy. Excitability studies were initially undertaken in 54 patients with type 2 diabetes (T2DM), and demonstrated a relationship between neuropathy-specific-quality-of-life and excitability markers that reflect activity of …
-
Effects of a Eucaloric Low Glycemic Index Diet on Insulin Sensitivity and Intramyocellular Lipid Content in Adults with Abdominal Obesity
… for 24 weeks. Participants underwent a 75g oral glucose tolerance test (OGTT) and had soleus-muscle IMCL measured by 1H-MRS at the beginning and end of the intervention period. Insulin sensitivity was assessed by the homeostatic model assessment index (HOMA) and the insulinogenic index (ISI) was …
-
The Effects of American Diabetes Association (ADA) Diabetes Self-Management Education and Continuous Glucose Monitoring on Diabetes Health Beliefs, Behaviors and Metabolic Control
… to an intensive follow-up group (IFG), utilizing continuous glucose monitoring system (CGMS), or a standard follow-up group (SFG) have any significant differences in mean HgbA1c values and health belief scores over time. Baseline HgbA1c values and health beliefs were measured using the revised …
-
Διερεύνηση της επίδρασης χορήγησης εκχυλίσματος κρόκου στο μεταβολικό έλεγχο ασθενών με σακχαρώδη διαβήτη τύπου 1
… 6 months. Glycemic control was assessed with a continuous glucose monitoring system and laboratory measurement of HbA1c and lipid profile was also examined. Blood pressure at baseline and end of intervention was also measured. Individuals were either on a continuous subcutaneous insulin infusion …
-
Αναδρομική εκτίμηση κατάστασης μη γραμμικών στοχαστικών δυναμικών συστημάτων: νέα μη γραμμικά φίλτρα Kalman, βελτιωμένα φίλτρα σωματιδίων και εφαρμογή σε συστήματα συνεχούς καταγραφής της γλυκόζης
… estimation of discrete time nonlinear stochastic systems. The formulation of the problem and some basic results are presented in the introduction, with emphasis on the Kalman Filter and its nonlinear variants (EKF, UKF, GHKF), while the Particle Filters are also mentioned. Then, some heuristic …
-
Miniaturization of Multiplexed sensor for continuous health monitoring systems
Continuous health monitoring systems are an essential part of current and future life. Monitoring biological signals helps us detect health issues in the early stages. Besides the early-stage disease diagnosis, some patients also need a continuous system to monitor their physical condition …
-
Comparison Of Diabetes Education Across Age Group, Gender, And Diabetes Type
… identify causes of sub-optimal control of blood glucose. Patient educational tools compared included: verbal information from a physician, consultations with a dietician, sessions with a diabetes educator, written materials such as pamphlets or brochures, Internet sources of information, use of …
-
Automated Processing Of Continuous Glucose Monitor (Cgm) Data To Study Onset Of Diabetes
… term condition that causes high levels of blood glucose, and it is necessary to get a complete picture of glucose levels which can lead to better treatment decision and better glucose control. The advent of Continuous Glucose Monitoring (CGM) is helping researches to track the blood glucose …
-
High protein diets, weight loss, glycaemic control and renal function in type 2 diabetes mellitus.
… and CHO timing on glycaemic control using a continuous glucose monitoring system. These studies showed a significant decrease in time spent with blood glucose (BG) above 10 mmol/L, maximal BG level and area under the BG curve indicating an overall beneficial effect of altering the CHO to …
-
Διερεύνηση του μεταβολισμού των υδατανθράκων κατά τη διάρκεια του τοκετού σε γυναίκες με σακχαρώδη διαβήτη κατά την κύηση
… metabolism, and the implementation of Continuous Glucose Monitoring System (CGMS) during this period of time. Method: Prospective study on the concentrations and the fluctuations of the substances associated with the metabolism of carbohydrates (glucose, insulin), intrapartum. Results: …
-
Electrospun Nanofibrous Membrane Based Glucose Sensor with Integration of Potentiostat Circuit
… is still under development, operates with poor monitoring and automation, and lacks sufficient communication among components. Moreover, demand for wearable bio-medical devices is expected to increase in the coming years. This situation presents a unique opportunity for electrical engineers to …
-
Data mining and mathematical modelling on diabetes
… (DM), which is characterized by significant glucose variation due to lack of insulin secretion, lack of insulin action, or both. DM can be broadly classified into two types: type 1 diabetes mellitus (T1DM) - which is caused mainly due to lack of insulin secretion and type 2 diabetes mellitus …
-
Development of physiological metabolic models in diabetes based on data mining techniques
… the problem of the short-term prediction of glucose concentration in the interstitial fluid in people with type 1 diabetes under free-living conditions. This thesis consists of three main parts. In the first part, we approached the specified problem via a time-invariant support vector …