Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 114 for “"Contrast Ratio"”.

  1. Lumens and contrast ratio in relation to the Digital Micromirror Device [tm]

    … competition is starting to match the lumens and contrast outputs of this device. In order for the DMD to maintain a competitive advantage, the lumens and contrast ratios have to improve. The thesis covers some aspects of the DMD that are open to change to improve the lumens and contrast ratio. …

    ttu Repository record for Lumens and contrast ratio in relation to the Digital Micromirror Device [tm] (opens in a new tab)

  2. Using the contrast ratio method and achromatic transmission densitometry as a substitute for Status A transmission densitometry with the Photographic Activity Test For Enclosure Materials

    … the current PAT. The analyzed metrics were: (1) ratio in reflection using normal illumination geometry and circumferential 45° viewing (0/45:c), (2) contrast ratio in reflection using diffuse illumination and 8° viewing geometry with specular component included (d/8:i), (3) contrast ratio in …

    rit Repository record for Using the contrast ratio method and achromatic transmission densitometry as a substitute for Status A transmission densitometry with the Photographic Activity Test For Enclosure Materials (opens in a new tab)

  3. Effect of changes in sintering parameters and coloring on mechanical and optical properties of translucent zirconia

    … zirconias. The specific aims are to compare the contrast ratio, grain size, and biaxial flexural strength of four different monolithic translucent zirconia materials using different coloring liquids. MATERIALS AND METHODS: For the test of the effect of sintering parameters on translucent zirconia …

    bu Repository record for Effect of changes in sintering parameters and coloring on mechanical and optical properties of translucent zirconia (opens in a new tab)

  4. High-fidelity Mini-LED and Micro-LED Displays

    … and high-luminance devices, 2) limited contrast ratio on mini-LED backlit LCD (mLED-LCD), 3) relatively high power consumption, and 4) compromised ambient contrast ratio. This dissertation tackles with each of these issues for achieving high display fidelity. Motion blur is caused by …

    ucf Repository record for High-fidelity Mini-LED and Micro-LED Displays (opens in a new tab)

  5. Inverse Scattering Image Quality with Noisy Forward Data

    … explored analytically and empirically using a contrast ratio. Theoretical contrast ratio estimates using the canonical PEC circular cylinder are derived. Empirical studies are conducted to confirm theoretical estimates and to provide examples of image quality vs SNR for more complex scatterer …

    byu Repository record for Inverse Scattering Image Quality with Noisy Forward Data (opens in a new tab) Download PDF for Inverse Scattering Image Quality with Noisy Forward Data (opens in a new tab)

  6. Wide Viewing Angle Liquid Crystal Displays

    … liquid crystal display predicts superb contrast ratio over wide viewing angles. Next, to increase the bright state transmittance while maintain the high contrast. Finally, to reduce the cost and improve the applicability of the broadband and wide-view circular polarizer, the device …

    ucf Repository record for Wide Viewing Angle Liquid Crystal Displays (opens in a new tab)

  7. Advanced liquid crystal displays with supreme image qualities

    … fast response time, wide color gamut, and high contrast ratio, which affect the final perceived image quality. Firstly, we investigate how response time affects the motion blur, and then discover the 2-ms rule. With advanced low-viscosity materials, new operation modes, and backlight modulation …

    ucf Repository record for Advanced liquid crystal displays with supreme image qualities (opens in a new tab)

  8. Fabrication of polymer infused multiphase glass ceramic block

    … °C. After sintering, density before resin infiltration of specimens was measured and calculated. All specimens were immersed in silane solution and infused with resin solution then cured under Hydraulic press. Specimens were examined for physical optical and mechanical properties including …

    bu Repository record for Fabrication of polymer infused multiphase glass ceramic block (opens in a new tab)

  9. Light transmission and wear of translucent zirconia after conventional and fast sintering cycle

    … form a disc which is then milled to form a restoration. Post milling of sintered zirconia restorations is necessary to obtain final mechanical and physical properties of the restoration. Traditionally conventional sintering cycles required 6-8 hours to sinter. Whereas, fast sintering cycles have …

    uab Repository record for Light transmission and wear of translucent zirconia after conventional and fast sintering cycle (opens in a new tab)

  10. High Performance Liquid Crystal Devices for Augmented Reality and Virtual Reality

    … luminance, fast response time and high ambient contrast ratio are critically needed. High-resolution density helps eliminate the screen-door effect, high luminance and fast response time enable low duty ratio operation, which plays a key role for suppressing image blurs. A dimmer placed in front …

    ucf Repository record for High Performance Liquid Crystal Devices for Augmented Reality and Virtual Reality (opens in a new tab)

  11. High Performance Three-Dimensional Display Based on Polymer-Stabilized Blue Phase Liquid Crystal

    … suffer from several drawbacks, such as low contrast ratio, relatively large hysteresis and short lifetime. In this dissertation, we investigate the material properties of PS-BPLC so as to improve the performance of PS-BPLC devices. Then we propose several PS-BPLC devices for the …

    ucf Repository record for High Performance Three-Dimensional Display Based on Polymer-Stabilized Blue Phase Liquid Crystal (opens in a new tab)

  12. Mechanical and optical properties of machinable and pressable glass ceramic

    … relative to the control and translucency by contrast ratio were recorded. The 3-point flexural strength test was performed using an Instron universal testing machine. Hardness test was performed using Vickers microhardness and surface roughness was measured using a contact profilometer. Data …

    bu Repository record for Mechanical and optical properties of machinable and pressable glass ceramic (opens in a new tab)

  13. Major contributors to the mottling defect in micro electromechanical projection displays

    … benefit larger diffraction angles which leads to contrast ratio and mottling concerns. Since Larry Hornbeck and Ed Nelson invented the DMDTM, the architecture has advanced by maximizing mirrored surface reflectivity to increase the contrast ratio and reduce wasted energy. Reducing the amount of …

    ttu Repository record for Major contributors to the mottling defect in micro electromechanical projection displays (opens in a new tab)

  14. Effect of sintering protocols on zirconia with various YTTRIA concentrations

    … flexural strength of different yttria concentrations of Tosoh zirconia materials (TZ-3YSB-E, TZ-3YB-E, Zpex, and Zpex Smile). MATERIALS AND METHODS: A total of 242 zirconia discs were manufactured from commercially available Tosoh zirconia powders. Zpex smile, Zpex, TZ-3YB-E, and TZ-3YSB-E …

    bu Repository record for Effect of sintering protocols on zirconia with various YTTRIA concentrations (opens in a new tab)

  15. Assessing the clinical viability of one- and two-piece zirconia implants as alternatives to titanium-based restorations in the anterior mandible

    … Crown optical behavior was characterized by contrast ratio measurement across five clinically derived thicknesses (0.60–1.45 mm) in three compositional layers. RESULTS: The titanium system recorded the lowest peak von Mises stress, followed by one-piece zirconia, with two-piece zirconia …

    bu Repository record for Assessing the clinical viability of one- and two-piece zirconia implants as alternatives to titanium-based restorations in the anterior mandible (opens in a new tab)

  16. Fabrication and Assessment of GaAs/AlGaAs Multiple Quantum Well Optical Modulators

    … modulators were designed to have a high contrast ratio and low insertion loss. For this purpose a 200 period structure, consisting of isolated wells 50 A wide, was grown by MOVPE. The electric field was applied, and light was incident, perpendicular to the epitaxial layers of the device. …

    glasgow Download PDF for Fabrication and Assessment of GaAs/AlGaAs Multiple Quantum Well Optical Modulators (opens in a new tab)

  17. Nonlinear Optical Studies of Photoelastic Effect and Magneto-Plasmonics

    … magnetic-induced second-harmonic generation (MSHG) interacting with surface plasmon, called "nonlinear magnetoplasmonics" (NMP), and the nonlinear index induced by a strong pump beam in Titanium doped sapphire crystal, referred to as population-induced nonlinear index effect.;The …

    wm-mary Repository record for Nonlinear Optical Studies of Photoelastic Effect and Magneto-Plasmonics (opens in a new tab)

  18. Using Electroencephalography as a Method to Determine Blue-Yellow and Red-Green Perceptual Asymmetries in the Human Visual System

    … colors defined by two intermediate axes in cone-contrast color space, which elicit equal average responses from the two axes of retinal color coding. Adult human observers are more sensitive to contrast along one of these axes than the other, and a primary motivation of this study is to find a …

    unr Repository record for Using Electroencephalography as a Method to Determine Blue-Yellow and Red-Green Perceptual Asymmetries in the Human Visual System (opens in a new tab)

  19. High dynamic range display systems

    High contrast ratio (CR) enables a display system to faithfully reproduce the real objects. However, achieving high contrast, especially high ambient contrast (ACR), is a challenging task. In this dissertation, two display systems with high CR are discussed: high ACR augmented reality (AR) display …

    ucf Repository record for High dynamic range display systems (opens in a new tab)

  20. Influence of Skin–Background Color Contrast on Percent Body Fat Estimates from a 2D Image-Based Smartphone Application

    … of skin pigmentation and skin–background contrast on estimation accuracy has not been systematically examined. The purpose of this study was to determine whether skin pigmentation, background luminance, and skin–background contrast ratios influence segmentation accuracy and %Fat estimates …

    alabama Repository record for Influence of Skin–Background Color Contrast on Percent Body Fat Estimates from a 2D Image-Based Smartphone Application (opens in a new tab)

Page 1 of 6