Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 1,004 for “"Contrast agents."”

  1. Calcium Selective Polymeric Contrast Agents

    … polymer synthesis to construct a novel polymeric contrast agent for the application of mild traumatic brain injury in which affects so many lives not only in the united states by also internationally as well. Our approach to tackling this issue is to take advantage of diffuse axial injury and the …

    clemson Repository record for Calcium Selective Polymeric Contrast Agents (opens in a new tab)

  2. New gadolinium contrast agents for MRI

    … this thesis on the design and synthesis of new contrast agents for MRI. Significant enhancements in the relaxivity of contrast agents for MRI can be gained by increasing the complex rotational correlation time ((_TR)). Incorporating a Gd(^111) ion within a ligand structure possessing a suitably …

    durham Repository record for New gadolinium contrast agents for MRI (opens in a new tab)

  3. MRI contrast agents for iron probing

    … but the development of small-molecule MRI contrast agents that respond directly to LIP remains limited. This thesis examines whether gadolinium-based molecular probes bearing appended iron-binding groups can convert probe–iron association into a measurable change in longitudinal …

    oxford Repository record for MRI contrast agents for iron probing (opens in a new tab)

  4. Artificial metallopeptides as MRI contrast agents

    … related to the use of Gd(III)-based MRI contrast agents in patients with compromised renal function, has driven the development of MRI contrast agents with high efficiencies (defined as MRI relaxivities). The use of alternative paramagnetic metals than Gd(III), such as Mn(II), or …

    birmingham Repository record for Artificial metallopeptides as MRI contrast agents (opens in a new tab)

  5. Theoretical modelling of ultrasound contrast agents

    … thesis compares theoretical models of ultrasound contrast agents to the acoustic response from single Microbubbles(MBs). The acoustic response was compared using a range of driving parameters. A rigid shelled contrast agent and a lipid shelled contrast agent were used in the comparison. While …

    edinburgh Repository record for Theoretical modelling of ultrasound contrast agents (opens in a new tab)

  6. Characterisation of Contrast Agents for Photoacoustic Imaging

    … both excellent spatial resolution with high contrast and specificity. This makes it well suited to clinical and pre-clinical studies of the physiological changes which accompany conditions such as cancer and cardiovascular disease. In order to fully realize the potential of this technique, …

    ucl Repository record for Characterisation of Contrast Agents for Photoacoustic Imaging (opens in a new tab)

  7. Chiral gadolinium complexes as potential contrast agents

    … gadolinium(III) ion makes it ideal for use as a contrast agent in Magnetic Resonance Imaging. As a result of its toxicity, gadolinium must be administered in the form of a kinetically inert complex. By coupling a gadolinium(III) chelate to a macromolecule, substantial gains in relaxivity (the …

    durham Repository record for Chiral gadolinium complexes as potential contrast agents (opens in a new tab)

  8. High-intensity contrast agents in medical imaging

    … project focused on the formation of novel, high-contrast MRI agents based on cyclen (1,4,7,10-tetraazacyclododecane) for the complexation of Gd<sup>3+</sup>. The aim of the project was to attach a number of these gadolinium contrast agents to a silicon-based central scaffold. This would allow …

    the-open-u Repository record for High-intensity contrast agents in medical imaging (opens in a new tab)

  9. Organic/inorganic hybrid nanoparticulate resonant contrast agents

    … development of responsive Gd<sup>3+</sup>-based contrast agents (CAs) that can report physiological variations in the tissue microenvironment.[1] Heterogeneous biological milieu and quantification of the CA concentration at the site of interest are the major limitations of responsive …

    oxford Repository record for Organic/inorganic hybrid nanoparticulate resonant contrast agents (opens in a new tab)

  10. Vaporized Perfluorocarbon Droplets as Ultrasound Contrast Agents

    Microbubble contrast agents for ultrasound are widely used in numerous medical applications, both diagnostic and therapeutic. Due to their size, similar to that of red blood cells, microbubbles are able to traverse the entire vascular bed, enabling their utilization for applications such as tumour …

    toronto-retro Repository record for Vaporized Perfluorocarbon Droplets as Ultrasound Contrast Agents (opens in a new tab)

  11. Gold nanoshells: Contrast agents for molecular imaging

    … examines work using nanoshell-based optical contrast agents for early cancer detection using scattering-based optical imaging systems. Metal nanoshells are a novel class of optically-tunable nanoscale material that are composed of a dielectric core (usually silica) surrounded by a metallic …

    rice Repository record for Gold nanoshells: Contrast agents for molecular imaging (opens in a new tab)

  12. Fluorinated Metal Complexes as MRI Contrast Agents

    … and provides 3-D imaging directly in vivo. Contrast agents are used in order to enhance the resolution of the images from MRI. All currently used contrast agents are based on gadolinium and image water protons in the human body. However, gadolinium-based contrast agents are principally …

    umn Repository record for Fluorinated Metal Complexes as MRI Contrast Agents (opens in a new tab)

  13. Development of Contrast Agents for Optoacoustic Imaging

    … use. Following excitation of optoacoustic contrast agents with ultrashort (~10 ns) pulses of near-infrared light, thermoelastic contractions and expansions of the molecule are produced and detected as acoustic waves. As the pathlength of light is reduced by half, and since near-infrared …

    oklahoma-thes Repository record for Development of Contrast Agents for Optoacoustic Imaging (opens in a new tab)

  14. Radical dendrimers as Magnetic Resonance Imaging Contrast Agents

    … de esta Tesis es desarrollar agentes de contraste (AC) para imagen de resonancia magnética (MRI), libres de metales y menos tóxicos que los utilizados actualmente en el diagnóstico clínico basados en Gd (III). Los dendrímeros son polímeros monodispersos con una estructura molecular bien …

    barcelona Repository record for Radical dendrimers as Magnetic Resonance Imaging Contrast Agents (opens in a new tab)

  15. Novel Contrast Agents in Photon-Counting Computed Tomography

    … for clinical CT applications: nanoparticle-based contrast agents and photon-counting (PC) detectors. Nanoparticles can be used to densely pack a highly attenuating element different than iodine and an engineered coating can be applied to the nanoparticles to create targeted agents and to enhance …

    heid-diss Repository record for Novel Contrast Agents in Photon-Counting Computed Tomography (opens in a new tab)

  16. Development and characterisation of advanced MRI contrast agents

    … tools in clinical medicine. Paramagnetic contrast agents (CAs), usually Gd-chelates, are often employed during an MRI scan to achieve better image contrast between a diseased and normal tissue. They work by modulating the longitudinal and transverse relaxation times of water protons within …

    uws Repository record for Development and characterisation of advanced MRI contrast agents (opens in a new tab)

  17. Lanthanide Functionalised gold nanoparticles as MRI contrast agents

    … and characterise nanoparticle-based MRI contrast agents. In the first instance, the DTPA (diethylenetriaminepentaacetic acid) based ligand was designed, synthesized and characterised. This ligand was utilised for stabilisation of gold nanoparticles. The gold nanoparticles protected by …

    whiterose Repository record for Lanthanide Functionalised gold nanoparticles as MRI contrast agents (opens in a new tab)

  18. Synthesis and characterisation of bifunctional MRI contrast agents

    … with Gd(III), could have potential as MRI contrast agents. <br></br><br></br>At present, cyclen is primarily functionalized by alkylation with halide substrates. In an attempt to prepare bifunctional ligands, cyclen was alkylated with derivatised amino acids. Elimination of the halide …

    the-open-u Repository record for Synthesis and characterisation of bifunctional MRI contrast agents (opens in a new tab)

Page 1 of 51