Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 217 for “"Contrast-to-noise"”
-
Application of the Generalized Contrast-to-Noise Ratio to Assess Photoacoustic Image Quality
The generalized contrast-to-noise ratio (gCNR) is a relatively new image quality metric designed to assess the probability of lesion detectability in ultrasound images. Although gCNR was initially demonstrated with ultrasound images, the metric is theoretically applicable to multiple types of …
-
Intraoperative ultrasound based on full waveform inversion for brain tumour surgery
… standard of practice in many institutions to determine the location of anatomical targets such as tumours during neurosurgery. However, when brain shift occurs, the targets become shifted which invalidates the patient-to-image mapping and compromises the accuracy of navigation. To restore …
-
Vergleich von Compressed Sensing-basierter und konventioneller MRT-Perfusionssequenzen hinsichtlich der Beurteilbarkeit myokardialer Ischämien in der kardialen Magnetresonanztomographie
… First pass perfusion imaging is a reliable tool in non-invasive detection of coronary artery disease (CAD) and widely used in clinical routine. We investigated a prototype sequence based on compressed sensing and compared it with a conventional echo perfusion sequence regarding image quality …
-
Efficient sensor array subsampling for plane-wave ultrasound imaging
… We propose a simple method for reducing the total amount of sampled data. First, we acquire the zero-angle data in full, and then we perform deterministic subsampling of the remaining nonzero-angle data. Our subsampling patterns are angle-specific and derived based on the zero-angle data …
-
Design and implementation of a depth-dependent matched filter to maximize signal-to-noise ratio in optical coherence tomography
… is an important goal in Optical Coherence Tomography (OCT) systems. One of the main factors that affect the depth of OCT imaging is the presence of noise. That’s why the study of noise statistics is an important problem. In the first part of this thesis we obtain an empirical estimate of …
-
Uncovering the Limits of Detection of Artificial Intelligence using Synthetic Lesions in Positron Emission Tomography
… (AI) for detection of lesions has been proposed to aid clinicians in detection tasks. However, before AI can be used clinically, the limits of detection must be studied to characterize AI performance. In this work, a library was constructed containing well-characterized spherical synthetic …
-
Signal behaviour in magnetic resonance angiography using rapid field echo sequences
… variants are considered which differ according to their use of transverse magnetization coherences. One sequence variant attempts to eliminate coherences by cycling the phase of the RF pulses. This approach is analyzed numerically and an optimal RF phase increment is presented. The theoretical …
-
Image processing and algorithms for medical applications
… artifacts—specifically Rician and Poisson noise—which obscure critical anatomical structures and compromise diagnostic accuracy. To address this, this dissertation systematically benchmarks traditional denoising filters (Median, NLM, BM3D with Anscombe transformation) against deep learning …
-
Analysis of Radiographic Contrast Markers for X-ray Digital Image Correlation of Tissue-Simulants Under Dynamic Load
The study of traumatic brain injury is critical to the improvement of protective equipment. Numerical models of brain deformation require real-world data for validation. In preparation for upcoming cadaver studies, a novel method of measuring displacement and strain fields of optically inaccessible …
-
Methodology development for breast cancer diagnosis using dual energy X-rays and digital tomosynthesis
… energy (DE) imaging techniques can suppress the contrast between adipose and glandular tissues improving the detectability of μCs and masses. The current thesis is focused on the study of DE X-ray method applied on breast imaging, in order to improve the detection of breast calcifications. A …
-
Methodology development for breast cancer diagnosis using dual energy x-rays and digital tomosynthesis
… energy (DE) imaging techniques can suppress the contrast between adipose and glandular tissues improving the detectability of μCs and masses. The current thesis is focused on the study of DE X-ray method applied on breast imaging, in order to improve the detection of breast calcifications. A …
-
Σύστημα αυτόματης επιλογής δυναμικού λυχνίας στην Υπολογιστική Τομογραφία - Η επίδραση στη δόση ακτινοβολίας ασθενούς και στην ποιότητα εικόνας
… των παρακάτω δεδομένων από το DICOM : Computed Tomography Dose Index (CTDIvol), Dose Length Product (DLP). Για τη μελέτη της ποιότητας εικόνας καταγράφηκαν τα παρακάτω δεδομένα από το DICOM : Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR).
-
Assessment of New Innovations In Pet/Ct For Respiratory Motion Correction
In oncological imaging, Positron Emission Tomography/Computed Tomography (PET/CT) is a vital tool used for stating and treatment response assessment of patients due to its ability to visualize and accurately quantify the bio-distribution of radiolabeled pharmaceuticals. However, due to the long …
-
Vergleich unterschiedlicher Late-Gadolinium-Enhancement Techniken bei verschiedenen kardialen Erkrankungen mittels kardiovaskulärer Magnetresonanztomographie
Hintergrund: Die kardiovaskuläre Magnetresonanztomographie (CMR) ist ein etabliertes diagnostisches Verfahren für kardiovaskuläre Erkrankungen. Sequenzen mit später Kontrastmittelanreicherung (Late Gadolinium Enhancement, LGE) erlauben eine genaue Gewebedifferenzierung bezüglich myokardialer …
-
Backscatter Spatial Coherence for Ultrasonic Image Quality Characterization: Theory and Applications
<p>Adaptive ultrasound systems, designed to automatically and dynamically tune imaging parameters based on image quality feedback, represent a promising solution for reducing the user-dependence of ultrasound. The efficacy of such systems, however, depends on the ability to accurately and reliably …
-
Digital image enhancement algorithms for 2D ultrasound imaging systems
… conventional single-scale nonlinear diffusion to a multiscale framework, i.e., Laplacian pyramid. From simulation and phantom studies, an average gain of 1.55 dB and 1.34 dB in contrast-to-noise ratio (CNR) were obtained compared with recently-developed speckle reducing anisotropic diffusion …
-
MRT-Leberdiagnostik mit dem leberspezifischen Kontrastmittel Gd-EOB-DTPA
… Phase III clinical trial the liver-specific MRI contrast agent Gd-EOB-DTPA was administered to 40 Patients. The substance showed very good tolerance. After intravenous bolus injection a non-specific vascular phase can be performed. After that liver-specific imaging is possible. Sensitivity and …
-
Developing Lower Cost Radiotherapy Solutions for Low and Middle Income Countries
… often focuses on state-of-the-art methods to provide small improvements in the treatment of patients in high-income countries, while less focus is put on providing low-cost treatments suitable for the majority of people in the world who have little or no access to radiotherapy. In an effort …
-
A differential evolution approach to noise reduction in biomedical images
Tomographic imaging modalities such as Magnetic Resonance Imaging (MRI), Optical Coherence Tomography (OCT) and Positron emission tomography (PET) are proving to be immensely helpful in the diagnosis of various pathologies in clinical environments. Images obtained using these modalities span the …
-
Patient Risk-Minimizing Optimization of Tube Current, Tube Voltage, and Spiral Start Angle in X-Ray Computed Tomography
This thesis proposes two automatic exposure control (AEC) techniques to reduce the radiation risk of computed tomography (CT) scans for patients. Modern AEC includes the selection of a constant tube voltage and tube current modulation (TCM) meaning that the tube current is adjusted per projection …
Page 1 of 11