Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 579 for “"Control loop"”.

  1. Control loop performance

    Control loop monitoring provides the opportunity to maintain high process performance. In this thesis, the regulation performance of a process is monitored by examining the time delay, static input-output relation, and the minimum achievable output variance of the process. The time delay estimate …

    ubc Repository record for Control loop performance (opens in a new tab) Download PDF for Control loop performance (opens in a new tab)

  2. Control loop performance assessment and oscillation detection

    In this thesis an analysis of process control loop performance based on the Harris's performance index is given. Good and poor performances will be defined and it will be shown that poor performance may be obtained when some loops are cycling. Then a procedure for localizing the oscillating loops …

    ubc Repository record for Control loop performance assessment and oscillation detection (opens in a new tab) Download PDF for Control loop performance assessment and oscillation detection (opens in a new tab)

  3. Digital control loop for power converter systems

    With the advance of microprocessors/DSP, digital control is increasingly used in various applications of switchmode power converter systems because of its advantages over analog control. The disadvantages, however, include limited signal resolution due to finite word length of processor and A/D …

    ubc Repository record for Digital control loop for power converter systems (opens in a new tab) Download PDF for Digital control loop for power converter systems (opens in a new tab)

  4. CONTROL LOOP PERFORMANCE MONITORING AND OPTIMIZATION BASED ON PLANT DATA

    The control of process variables is of great importance to a production plant. The failure of control loops may lead to off-spec production or cause the deterioration of equipment, which translate into economic losses. A method of control loop performance monitoring based on Stochastic Process …

    nus Repository record for CONTROL LOOP PERFORMANCE MONITORING AND OPTIMIZATION BASED ON PLANT DATA (opens in a new tab) Download file for CONTROL LOOP PERFORMANCE MONITORING AND OPTIMIZATION BASED ON PLANT DATA (opens in a new tab)

  5. Novel methodologies for assessment and diagnostics in control loop management

    … de ferramentas para auditar malhas de controle. Na indústria, o interesse por esse tipo de software é crescente, devido ao benefício trazido: garantir o exato desempenho para cada controlador significa atingir pontos de operação mais lucrativos. Todavia, as metodologias disponíveis na …

    brazil-ufrgs Repository record for Novel methodologies for assessment and diagnostics in control loop management (opens in a new tab)

  6. Control Loop Interactions and Their Mitigation Schemes in VSC-HVDC Systems

    … of AC systems to hybrid AC-DC systems is the control of converters. Each converter station owns various control loops that require proper tuning in their stand-alone mode of operation. Furthermore, control loops of adjacent converters may also impact one another, and as a result, there must be …

    waterloo Repository record for Control Loop Interactions and Their Mitigation Schemes in VSC-HVDC Systems (opens in a new tab)

  7. A Piezoelectric Actuated Scanning Mirror System Utilizing a Type One Control Loop

    … this thesis is to design and build an improved control loop for a piezoelectric actuated scanning mirror system. A control system has been built having zero steady state position error and an 80 Hertz bandwidth. This was achieved by placing the piezoelectric actuator in the feedback path of an …

    ucf Repository record for A Piezoelectric Actuated Scanning Mirror System Utilizing a Type One Control Loop (opens in a new tab)

  8. Control loop measurement based isolation of faults and disturbances in process plants

    … methods. These techniques include process control loop status monitoring, fault localisation in a number of interacting control loops and the detection and isolation of multiple oscillations in a multi-loop situation. Not only do they make use of controlled variables, but they also make use …

    glasgow Download PDF for Control loop measurement based isolation of faults and disturbances in process plants (opens in a new tab)

  9. Hybrid PWM Update Method for Time Delay Compensation in Current Control Loop

    … proposed to eliminate the effect of the one-step control time delay Td one without losing the full duty cycle range. Without the Td one to cause linear phase shifts that limit the control bandwidth and affect closed-loop stability, a very high quality digital current control can be achieved, such …

    vt Repository record for Hybrid PWM Update Method for Time Delay Compensation in Current Control Loop (opens in a new tab)

  10. Simulation study of the roll control loop of an operational surface to air missile

    This thesis studies the roll loop of an operational surface to air missile as an example of a typical self adaptive control system. The missile studied also exhibits a phenomenon called ROLL WANDER, a low frequency oscillation in missile roll orientation. Because of this, the thesis is developed in …

    nps Repository record for Simulation study of the roll control loop of an operational surface to air missile (opens in a new tab)

  11. The Use of Computer Vision to Close the Control Loop of a Robot Arm

    … through the use of computer vision to close the control loop on the arm and also give the robot environmental intelligence. The basic subdivisions of a computer vision system are sensing, segmentation, description, recognition, and interpretation. When the vision processor analyzes a scene it can …

    ucf Repository record for The Use of Computer Vision to Close the Control Loop of a Robot Arm (opens in a new tab)

  12. Multi-Modular Integral Pressurized Water Reactor Control and Operational Reconfiguration for a Flow Control Loop

    … to a single turbine, resulting in a steam-mixing control problem with respect to “load-following” scenarios, such as varying load during the day or reduced consumption during the weekend. To solve this problem a single-module IRIS SIMULINK model previously developed by another researcher is …

    utk-theses Repository record for Multi-Modular Integral Pressurized Water Reactor Control and Operational Reconfiguration for a Flow Control Loop (opens in a new tab)

  13. PI-control in dual duct systems : a study on manual tuning and control loop interaction

    Good HVAC control schemes in buildings help reduce energy use and maintain occupant comfort. PID controllers are widely used in commercial buildings to keep variables such as temperature, pressure and humidity at predefined setpoints. These controllers, when they do not include autotuners, must be …

    concordia Download PDF for PI-control in dual duct systems : a study on manual tuning and control loop interaction (opens in a new tab)

  14. Application of system cultivation and the philosophy of statistical process control to a PI flow control loop

    … use of the techniques of statistical process control (SPG). While the philosophy of SPG is very sound, the applications of its traditional techniques are limited in the multivariable environment of continuous chemical processing. Furthermore, traditional SPG is not useful in the analysis of …

    ut-knoxville Repository record for Application of system cultivation and the philosophy of statistical process control to a PI flow control loop (opens in a new tab)

  15. Trusted Software Updates for Secure Enclaves in Industrial Control Systems

    Industrial Control Systems (ICSs) manage critical infrastructures such as water treatment facilities, petroleum refineries, and power plants. ICSs are networked through Information Technology (IT) infrastructure for remote monitoring and control of physical processes. As ICSs integrate with IT …

    vt Repository record for Trusted Software Updates for Secure Enclaves in Industrial Control Systems (opens in a new tab)

Page 1 of 29