  1. method of verification of the total treatment time for the APBI (Accelerated Partial Breast Irradiation) devices

    … by the treatment planning system (TPS) when the CONTURA MLB or the SAVI applicator are used for APBI treatments has been developed. The method compares the time generated by the TPS to a predicted time, calculated by inserting parameters obtained from the TPS in equations generated in this …

    fau Repository record for method of verification of the total treatment time for the APBI (Accelerated Partial Breast Irradiation) devices (opens in a new tab)

  2. Dose Modification Factor Analysis of Multi-Lumen Brachytherapy Applicator with Monte Carlo Simulation

    Multi-lumen applicators like the Contura (SenoRx, Inc.) are used in partial breast irradiation (PBI) brachytherapy in instances where asymmetric dose distributions are desired, for example, when the applicator surface-to-skin thickness is small (<7mm). In these instances, the air outside the …

    ohiolink Repository record for Dose Modification Factor Analysis of Multi-Lumen Brachytherapy Applicator with Monte Carlo Simulation (opens in a new tab)

  3. Experimentelle Untersuchungen zur Genauigkeit eines digital erzeugten Implantatplanungsmodells (MExPERT IPM)

    … des 3D-Modells mit dem Präzisionsmessgerät CONTURA G2 überprüft. Nach wiederholter Herstellung einer Bohrschablone auf demselben IPM wurde die Genauigkeit der Bohrhülsenposition ebenfalls mit dem CONTURA G2 vermessen. Die Vermessung der Genauigkeit der Bohrhülsenposition nach wiederholter …

    fu-berlin Repository record for Experimentelle Untersuchungen zur Genauigkeit eines digital erzeugten Implantatplanungsmodells (MExPERT IPM) (opens in a new tab)

  4. Comparación in vitro de los cambios dimensionales de modelos con yeso tipo IV en relación a la proporción polvo-líquido para la preparación del alginato.

    … measuring scanning technology provided by the Contura G2 Zeiss. In the locations E, F, G and H, which corresponded with measurements from the base to the top of the pillars, statistically significant differences were observed.

    upc-peru Repository record for Comparación in vitro de los cambios dimensionales de modelos con yeso tipo IV en relación a la proporción polvo-líquido para la preparación del alginato. (opens in a new tab)

  5. Comparación in vitro de la precisión dimensional de dos técnicas de impresión

    … una máquina especializada en coordenadas, modelo Contura G2 con tecnología de Scanning por contacto ZEISS. Se realizaron las pruebas estadísticas Kruskal-Wallis y U de Mann-Whitney. Resultados: Se encontraron diferencias estadísticamente significativas (p˂0.001) en las medidas MD1, MD2, AL2 al …

    upc-peru Repository record for Comparación in vitro de la precisión dimensional de dos técnicas de impresión (opens in a new tab)

  6. The Effects of Build Orientation, Diameter and Printhead Life On the Cylindricity of Three-dimensionally Printed Parts

    … (ANOVA) study was conducted using the Zeiss Contura® G2 CMM located at Hartwig Inc. in Kansas City, Missouri. Eleven batches with a total of 132 specimens were produced and measured. Each batch of printed parts consisted of twelve specimens of two different diameters and three different build …

    indystate Repository record for The Effects of Build Orientation, Diameter and Printhead Life On the Cylindricity of Three-dimensionally Printed Parts (opens in a new tab)

  7. Comparación in vitro de la alteración dimensional del modelo definitivo según el tiempo de vaciado de la silicona por condensación

    … with a specialized coordinate machine, model Contura G2 with ZEISS Scanning contact technology. Results: The non-parametric test of Wilcoxon was used for this study. It was found that only 6 of 8 locations had statistically significant differences: A, C, D, E, F y G. We found there´s more …

    upc-peru Repository record for Comparación in vitro de la alteración dimensional del modelo definitivo según el tiempo de vaciado de la silicona por condensación (opens in a new tab)

  8. In-vitro-Untersuchungen zur dreidimensionalen Genauigkeit der Implantatplanung mit verschiedenen MExPERT-IPM-Systemen

    … mit der Präzisionsmessmaschine ZEISS Contura G2 (Carls Zeiss Industrielle Messtechnik, Oberkochen, Germany) wurden die linearen Abweichungen in den drei Raumebenen sowie zwei anguläre Abweichungen gewonnen. Für den statistischen Vergleich der m Vorzeichenrangtest verwendet; für den …

    fu-berlin Repository record for In-vitro-Untersuchungen zur dreidimensionalen Genauigkeit der Implantatplanung mit verschiedenen MExPERT-IPM-Systemen (opens in a new tab)

  9. The Comparison of Dose Modification Factors for Two Multi-Lumen Brachytherapy Applicators used in Partial Breast Irradiation

    … for two brachytherapy applicators, which include ConturaTM (Bard, Inc.) and SAVITM (Cianna Medical, Inc.). For each applicator, both symmetric and asymmetric plans will be examined to show which produces a larger difference from the dose distribution predicted by the planning system. Also, the …

    ohiolink Repository record for The Comparison of Dose Modification Factors for Two Multi-Lumen Brachytherapy Applicators used in Partial Breast Irradiation (opens in a new tab)