Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 235 for “"Conventional imaging"”
-
ADVANCED SHADOW MOIRE WITH NON-CONVENTIONAL IMAGING ANGLES
… realized using non-zero viewing angles with the conventional shadow moiré technique. Advanced configurations to accommodate the non-zero viewing angles are developed to cope with direct reflection encountered on the conventional setup. An expanded governing equation for the configuration is …
-
Comparison of 18F-Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (18F-FDG PET/CT) and conventional imaging (CI) for locally advanced breast cancer staging: a prospective study from a tertiary hospital cancer centre in Western Cape
… accuracy between whole-body PET/PET-CT and conventional imagine (CI) for staging LABC. Methods: A total of 42 participants with clinical stage III and a select few stage II breast cancer underwent both 18F-FDG PET/CT and CI. Results: 18F-FDG PET/CT found significantly more (p=0.0077) distant …
-
H συμβολή της PET/CT στην επανασταδιοποίηση ασθενών με καρκίνο μαστού, αυξημένους καρκινικούς δείκτες και αρνητικά ή αμφίβολα ευρήματα στον συμβατικό απεικονιστικό έλεγχο
… may not be associated with abnormal findings in conventional imaging modalities. PET/CT, by combining morphological and metabolic information in the same examination, overcomes the limitation of anatomic imaging techniques and may contribute to the investigation of these patients, showing sites …
-
Nuevas técnicas de adquisición de light field y fase de frente de onda
Conventional imaging sensors are only capable of acquiring information on intensity, leaving aside the wave-front phase of the complex field. The wave-front phase contains information on the propagation direction of light rays and can be used to study the media in which the light has propagated. In …
-
Inverse scattering approach to imaging using Marchenko equations in the presence of a free surface, An
… surface measurements. In exploration seismology, imaging algorithms use estimates of the Green's functions along with surface measurements to image the subsurface, i.e. locate the Earth's interfaces and its properties, so as to identify valuable energy resources. These conventional imaging …
-
Excursion Areas of Intensity Due to Random Optical Waves
… process. Applications discussed include coherent imaging, conventional imaging, and damage areas on laser illuminated materials.
-
Techniques for capture and analysis of hyperspectral data
… analysis of baked sponges using hyperspectral imaging. By comparing hyperspectral images of sponges of varying ages with the results of an expert tasting panel, a strong correlation is shown between the hyperspectral data and human determined taste, texture and appearance scores. This data is …
-
Aspects of imaging of the anterior region of the edentulous mandible prior to dental implant placement
Objectives To gain an understanding of the imaging prescription of implant practitioners when placing implants in the anterior edentulous mandible and to investigate the impact of cross sectional imaging on diagnostic thinking, treatment planning and patient outcome. Methods •A web-based …
-
Subwavelength Sensing Using Nonlinear Feedback in a Wave-Chaotic Cavity
<p>Typical imaging systems rely on the interactions of matter with electromagnetic radiation, which can lead to scattered waves that are radiated away from the imaging area. The goal such an imaging device is to collect these radiated waves and focus them onto a measurement detector that is …
-
Characterizing surface wave interactions in finite superlens systems to improve imaging performance
… applications in the fields of manufacturing and imaging. Surging industrial demand for increased lensing resolution have pushed conventional imaging techniques to their performance limits. To meet this burgeoning industrial need, a comprehensive selection of super-resolution imaging technologies …
-
Optimal Denoising for Photon-limited Imaging
Most conventional imaging modalities detect light indirectly by observing high energy photons. The random nature of photon emission and detection are often the dominant source of noise in imaging. Such case is referred to as photon-limited imaging, and the noise distribution is well modeled as …
-
Qualitative and quantitative whole-body MRI assessment of metastatic disease in patients with radio-recurrent prostate cancer
… the evaluation of whole-body magnetic resonance imaging (WB-MRI) as a single step imaging technique for assessment of metastasis in patients presenting with radio-recurrent prostate cancer (PCa). The work presented is the interim analysis of the LOCATE (localising occult prostate cancer …
-
A Task-Specific Approach to Computational Imaging System Design
The traditional approach to imaging system design places the sole burden of image formation on optical components. In contrast, a computational imaging system relies on a combination of optics and post-processing to produce the final image and/or output measurement. Therefore, the …
-
Ο ρόλος του FDG PET/CT στη διάγνωση περιτοναϊκών εμφυτεύσεων σε ασθενείς με ενδοκοιλιακούς όγκους
… markers CEA, CA 19-9 and/or CA 125 and normal conventional imaging findings during follow-up. A second subgroup was studied that included 43 pts with colorectal cancer only, who underwent whole-body 18F-FDG PET/CT examination, due to increased level of tumor markers CEA and / or CA 19-9 during …
-
Multispectral Method for Apple Defect Detection using Hyperspectral Imaging System
Hyperspectral imaging is a non-destructive detection technology and a powerful analytical tool that integrates conventional imaging and spectroscopy to get both spatial and spectral information from the objects for food safety and quality analysis. A recently developed hyperspectral imaging system …
-
Applications of Computational Intelligence and Data Fusion Techniques for Biomedical Images
… by exploring the fusion of deep learning with conventional imaging processing methods, emphasizing the enhancement of diagnostic specificity, and addressing the critical aspect of explainability in AI diagnostics" -- Abstract, p. iv
-
Two dimensional angular domain optical imaging in biological tissues
Optical imaging is a modality that can detect optical contrast within a biological sample that is not detectable with other conventional imaging techniques. Optical trans-illumination images of tissue samples are degraded by optical scatter. Angular Domain Imaging (ADI) is an optical imaging …
-
Mild Traumatic Brain Injury Assessment using Functional Connectivity Estimators on Resting State EEG Analysis
… to lack of symptoms or non-apparent lesion in conventional imaging. In attempts to create an mTBI biomarker, we analyze brain connectivity based on Phase Locking Values (PLV), imaginary PLV, and amplitude envelope correlation (AEC) computed from electroencephalography activity obtained at the …
-
Improved Cerebral Perfusion Imaging Parameter Selection for Dynamic Contrast-Enhanced Magnetic Resonance
… contrast-enhanced (DCE) magnetic resonance (MR) imaging is a standard method for assessing perfusion outside the brain and blood brain barrier permeability. Recent findings have shown that DCE imaging also has potential for acquiring and generating robust and reliable quantitative cerebral …
Page 1 of 12