Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 17 of 17 for “"Conventional ventilation"”.
-
Zone and Drip Cooling Comparisons for Lactating Swine
A comparison of drip cooling, zone cooling, and conventional ventilation was performed on lactating swine. Overall, the cooling systems did not significantly improve swine performance. The drip and zone systems highly significantly lowered sow respiration rates by 40 and 28 percent, respectively, …
-
Snout Ventilation and Cooling Effects on Swine
… 1) cooled air directed at the sow head area plus conventional ventilation, 2) outside air directed toward the sow head area plus conventional ventilation, and 3) conventional summer ventilation only. 2. Document the effects of the above listed environmental alternatives on swine performance as …
-
Measurement and evaluation of microbial contamination during orthopedic implant surgery
… surgeries in ORs equipped with either a conventional ventilation system (n=10), conventional ventilation system with mobile laminar airflow units (n=3) or laminar airflow ventilation system (n=11). The measurements were conducted via active air sampling through gelatin-filters with a …
-
Σύγκριση καρδιο-πνευμονικών μεταβλητών μεταξύ υψίσυχνου αερισμού χαμηλών συχνοτήτων με ή χωρίς ενδοτραχειακή εμφύσηση οξυγόνου και υψίσυχνου αερισμού υψηλών συχνοτήτων σε ασθενείς με βαρύ σύνδρομο αναπνευστικής δυσχέρειας (ARDS)
… reduction in pulmonary compliance. Mechanical ventilation is life-saving, but may traumatize the lungs (eg volutrauma, barotrauma, atelectrauma, and biotrauma). The use of low (i.e. 5-8 mL/kg predicted body weight) tidal volumes, and high positive end-expiratory pressure (PEEP), aims at …
-
Optimizing Wind Wing Wall Ventilation in High-Rise Buildings within Dense Urban Hot and Humid Climate.
… investigates how wing walls can increase natural ventilation in high-rise structures, particularly in hot, humid locations such as Mumbai, India. Using wind flow simulations and computational fluid dynamics (CFD) modeling, the study investigates how wind direction and the installation of wing …
-
Behovsstyrd Ventilation På Kryssningsfartyg - Potential till användning och energibesparing
… suitability of implementing demand-controlled ventilation on board cruise vessels is examined in the following literature review. This type of ventilation strategy is sometimes used in buildings ashore. Three sub questions where used answer the main question about the suitability, and they are …
-
Periodic Variable Mechanical Ventilation and Dynamics of Recruitment and De-recruitment in Experimental Acute Respiratory Distress Syndrome
Background Controlled mechanical ventilation with randomly variable tidal volume patterns has been shown to improve gas exchange and respiratory system mechanics compared to conventional ventilation in numerous experimental models of acute respiratory distress syndrome (ARDS). Multiple mechanisms …
-
A Demand-Controlled Ventilation (DCV) Systems Approach Towards Energy-Efficient Management for Improved Indoor Air Quality (IAQ)
… for educational environments, as poor ventilation and inadequate air filtration have been linked to adverse health effects and reduced cognitive performance. In commercial spaces, insufficient IAQ can lead to occupants' discomfort, increased sick leave, and lower productivity, whereas …
-
Cardiopulmonary outcomes in school age children born extremely prematurely
… appears to decline in infancy, in infants conventionally ventilated at birth. Pulmonary hypertension has been described in babies born extremely preterm. Methods: In a randomized controlled multi-center study, high frequency oscillation (HFO) was compared to conventional ventilation (CV) in …
-
An evaluation of the economic benefits of active cooling and carbon dioxide enrichment of greenhouse cucumbers (Cucumis sativus L.) : a thesis presented in partial fulfilment of the requirements for the degree of Master of Horticultural Science at Massey University
… with a refrigeration system rather than conventional ventilation makes it possible to maximise the fractional enrichment time for carbon dioxide, and more importantly enrich during periods of high photosynthetically active radiation. Using conventional climate control methods, enrichment …
-
Humidity control in confined building spaces using a liquid desiccant dehumidifier
… can be discharged through continuous exhaust ventilation. In the dissertation, the physical system design is described and dehumidifier performance models and CFD models are integrated and developed. Numerical simulations were conducted to compare the results of a conventional ventilation …
-
Exploration of the Linkage between the A:a gradient and oxygen transfer efficiency as a measure of response to treatment with inhaled nitric oxide in a heterogenous group of newborns treated for acute hypoxic respiratory failure
… measures. Infants’ data were grouped by mode of ventilation to determine whether shunt differed between groups. Infants were then grouped by responders and non responders to examined differences in the A:a gradient over the treatment period. Finally gestational age was examined as a possible …
-
Spatial distribution of ventilation and perfusion in the lateral decubitus posture
… effects of posture, bilateral PEEP, differential ventilation with unilateral PEEP and left lung atelectasis on regional ventilation (V̇A) and perfusion (Q̇) in the lateral decubitus posture were studied. Q̇ and V̇A were measured using 15-mum i.v. injected and 1-mum aerosolized fluorescent …
-
Interactions between water-based fixed fire-fighting systems and longitudinal ventilation in road tunnels
Notwithstanding well-developed tunnel ventilation strategies, devastating tunnel fire catastrophes have never been absent in past decades, ringing an alarm bell for the tunnel community about the inadequacy of the conventional fire-fighting systems. In such context, proposals have been made to add …
-
Systems design and uncertainty quantification of co2 capture from air
… improvement in performance as compared with conventional ventilation systems. CO2 capture systems have been modeled by understanding the physical process and solving coupled heat and mass balances equations through numerical simulators. Model parameters such as mass transfer coefficient, …
-
Εφαρμογή της τομογραφίας ηλεκτρικών αντιστάσεων στο σύνδρομο αναπνευστικής δυσχέρειας πρόωρων νεογνών πριν και μετά τη χορήγηση του επιφανειοδραστικού παράγοντα
… change (ΔZ); redistribution of regional lung ventilation was assessed as well. Airway pressure and arterial blood gases were recorded. Maltron Sheffield Mk 3.5 EIT 8 electrode system that was used in our research, designed mainly for neonates, is easy to use and has the ability to calculate …