Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 48 for “"Conversion electron"”.
-
Conversion electron and low energy gamma-ray spectrometer.
A conversion electron and low energy gamma-ray spectrometer has been developed using a silicon lithium-drifted semiconductor detector. The spectrometer has a resolution of 2 Kev for 100 Kev electrons and photons under optimum conditions. The energies of these electrons and gamma-rays can be …
-
Feasibility Studies of Conversion Electron Mossbauer Spectroscopy (CEMS) of Iron-Doped InP
An electron detector for conversion electron Mossbauer spectroscopy (CEMS) has been designed and built. Tests have been performed to study the effects on the electron detector resolution with respect to high anode voltage, He/CH4 gas flow rate, and counting rate. These parameters have been …
-
Conversion-electron and [gamma]-ray experiments with the decay of bromine-82 and strontium-83
Thesis (Ph. D.)--Michigan State University. Department of Physics, 1967
-
Auger and conversion electron spectroscopy of medical isotopes and the construction of a new atomic radiation database
A localized source of electrons can be provided by radioisotopes that emit Auger electrons through atomic relaxation as part of their electron capture and/or internal conversion decays. Most of these Auger electrons could deposit their energies over short distances (nanometre to micrometre) in …
-
Studies in the mass 160 decay chain. gamma-ray and conversion electron spectroscopy for the 160lu-160yb, 160yb-160tm, 160tm-160er decay schemes.
… 160Yb have been studied using gamma-ray and conversion electron spectroscopy following the beta+/EC decay of 160Lu. Excited states in the nuclei 160Tm and 160Er have been studied following the beta+/EC decay of 160Yb and 160Tm, respectively. The data for the present study were obtained at …
-
Konversijos elektronų Mesbauerio spektroskopijos taikymas pitinginės korozijos tyrimui /
Conversion Electron Mossbauer Spectroscopy Application for Pitting Corrosion Investigation.
-
Accurately determining the number of Auger electrons per nuclear decay for medical isotopes
… in cancer treatment as low-energy Auger electrons (below 5 keV) deposit a high radiation dose over a very short distance. Auger-based therapy is attractive as, in contrast to alpha and beta particles, the affected volume around the decaying radionuclides is much smaller than the volume of …
-
The decay scheme of Se⁷⁵
… ray intensities, gamma-gamma coincidences, and conversion electron-gamma coincidences. A decay scheme with five excited As⁷⁵ levels at 200, 265, 280, 305 and 402 kev. is proposed. Multipolarities are assigned to the transitions between these levels on the basis of conversion coefficients, …
-
The decay of [formula omitted]
… a scintillation spectrometer and beta-gamma, conversion-electron gamma coincidence techniques. The results support the simpler decay scheme proposed by Van Wijngaarden and Connor. The beta decay has three components with end-point energies and intensities of 659+3 kev(67 .3%), 411 kev (2.5%) …
-
The 0.230 Millisecond Isomer in ¹⁴⁶Eu
… on the study of the in-beam and pulsed beam conversion electron, and gamma ray singles spectra. The assignment of spins and parities was based on the multipolarities of the 274.9, 293.9, 358.2 and 377.0 keY transitions determined by conversion coefficient measurements, and the assumed 9⁺ …
-
The decay of mass-separated ¹⁹³Pb to ¹⁹³Tl
… were used to gather multiscaled gamma-ray and conversion electron singles data and gamma-gamma and gamma-conversion electron coincidence data. A decay scheme was deduced from these data.</p> <p>The decay rate of the 13/2 <sup>+</sup>isomer of <sup>193</sup>Pb was measured to be 5.65±0.07 …
-
Beta and gamma ray spectroscopic analysis of the radiations emitted in the decay of selenium 75
… the study of the Se⁷⁵ decay scheme. The internal conversion spectrum as well as the photoelectron spectra (using bismuth and lead radiators) were measured with a modified thin lens magnetic spectrometer. A technique was developed for accurate determination of the transmission of the spectrometer …
-
Levels in ⁹⁷Tc , ⁹⁹Tc , ¹⁰¹Tc and ¹⁰¹Ru
… , ¹⁰¹Tc and ¹⁰¹Ru have been studied using the electron-capture decay of ⁹⁷Ru and the beta decays of ⁹⁹Mo, ¹⁰¹Mo and ¹⁰¹Tc, respectively. The energies and intensities of the gamma rays involved in these decays were measured with high precision by Ge(Li) detectors. Gamma-gamma coincidence …
Page 1 of 3