Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 29 for “"Converter station"”

  1. The prediction and control of transients in thyristor values

    … non-repetitive electrical transients in an HVDC converter station may be controlled for minimum overall cost. Several methods of inrush control are proposed and studied. The preferred method, whose development is reported in this thesis, would utilize two magnetic materials, one of which is …

    aston Repository record for The prediction and control of transients in thyristor values (opens in a new tab)

  2. Estratégia de controle de margem de tensão aprimorada para sistemas HVDC multiterminal com base no conversor modular multinível para robustez frente a perturbações

    … grid interconnections, and offshore wind energy converter systems (WECS). The main purpose of an MTDC grid is to share power among the AC grids. However, this technology presents challenges in its operation and control. Therefore, for its control it is necessary to use appropriate control system …

    brazil-ufrn Repository record for Estratégia de controle de margem de tensão aprimorada para sistemas HVDC multiterminal com base no conversor modular multinível para robustez frente a perturbações (opens in a new tab)

  3. HVDC Transmission System with Medium-Frequency Transformers

    … isolation in High Voltage Direct Current (HVDC) converter stations, standard transformers operating at grid frequency are currently used. These devices tend to be very large and heavy, which is undesirable in many applications. Transformers where the magnetic parts operate at a frequency …

    chalmers Repository record for HVDC Transmission System with Medium-Frequency Transformers (opens in a new tab)

  4. Three-dimensional analysis of airflow and temperature in a thyristor valve hall

    … in a thyristor valve hall located at the Dorsey Converter Station, owned and operated by Manitoba Hydro. The goal of this analysis was to determine the configurations that result in increased air-side cooling effectiveness in the valve hall. The governing equations are solved using the …

    manitoba Repository record for Three-dimensional analysis of airflow and temperature in a thyristor valve hall (opens in a new tab)

  5. Travelling Wave Based DC Line Fault Location in VSC HVDC Systems

    … techniques work well for line commutated converter (LCC) based high voltage direct current (HVDC) transmission lines, but the large capacitors at the DC line terminals makes application of the same techniques for voltage source converter (VSC) based HVDC schemes challenging. A range of …

    manitoba Repository record for Travelling Wave Based DC Line Fault Location in VSC HVDC Systems (opens in a new tab)

  6. Online partial discharge measurement in a high noise environment

    … (PD) in a high-voltage direct current (HVDC) converter station. The HVDC station is a particularly challenging environment for PD measurement due to elevated interference levels caused from the switching of the thyristor-controlled converters. Online PD measurements are performed on two …

    manitoba Repository record for Online partial discharge measurement in a high noise environment (opens in a new tab)

  7. DIGITAL SIMULATION OF AN AC/DC SYSTEM IN DIRECT-PHASE QUANTITIES

    … AC/DC system. This system consists of an AC/DC converter connected to a synchronous generator at its terminals as well as to an infinite bus-bar through a short transmission line. A group of filters is also connected at the converter AC bus-bar. The various components of the system have been …

    sask Repository record for DIGITAL SIMULATION OF AN AC/DC SYSTEM IN DIRECT-PHASE QUANTITIES (opens in a new tab)

  8. Aspects of conversion of the Nelson River bipole 2 HVDC converters from 12-pulse to 6-pulse operation

    … confronted with a serious problem involving the converter transformers for the bipole 2 operation of the Nelson River HVDC transmission system. The transformer problem left the negative pole of bipole 2, pole 3, without a converter transformer at each converter station. Since the transformer …

    manitoba Repository record for Aspects of conversion of the Nelson River bipole 2 HVDC converters from 12-pulse to 6-pulse operation (opens in a new tab)

  9. Control Loop Interactions and Their Mitigation Schemes in VSC-HVDC Systems

    … as well as combating climate change, various converter-interfaced renewable energy sources (RESs) are being integrated into the power systems. The transfer of renewable power generated by the RESs such as offshore wind farms to remote load centers may require the use of direct current (DC) …

    waterloo Repository record for Control Loop Interactions and Their Mitigation Schemes in VSC-HVDC Systems (opens in a new tab)

  10. IMPACT OF HVDC INVERTER STATION FAULTS ON TURBINE-GENERATOR SHAFT TORSIONAL TORQUES

    … governor controls and variable speed drive converters. In most of the reported studies concerned with the interaction of HVDC systems with turbine-generator shafts, attention has been focused on the effect of the HVDC controllers on this phenomenon.Fewer studies have, however, investigated …

    sask Repository record for IMPACT OF HVDC INVERTER STATION FAULTS ON TURBINE-GENERATOR SHAFT TORSIONAL TORQUES (opens in a new tab)

  11. AC Voltage Control of a Future Large Offshore Wind Farm Network Connected by HVDC

    … loss. This thesis considers the voltage source converter and high voltage direct current (VSC-HVDC) technology as the future grid connection for the offshore wind farm network, which is more controllable and has better transmission efficiencies for long distance and high power cable transmission …

    durham Repository record for AC Voltage Control of a Future Large Offshore Wind Farm Network Connected by HVDC (opens in a new tab)

  12. Control of an H-bridge modular multilevel converter for reliable operation of DC transmission systems

    … schemes for an H-bridge modular multilevel converter (MMC) that can be used to enhance the transient response of DC transmission systems. The schemes enable H-bridge MMC cell capacitor voltages to be regulated independent of the DC link voltage in a DC transmission system, and also permit …

    strathclyde Repository record for Control of an H-bridge modular multilevel converter for reliable operation of DC transmission systems (opens in a new tab)

  13. Partial discharge behaviour under AC and DC conditions including novel manufacture techniques for void-type dielectric samples

    … of the electromagnetic field emissions from HVDC converter station on the behaviour of high frequency current transformers (HFCT). A range of sensors of different constructions were tested in a controlled electromagnetic field environment. The relative immunity of the sensors to the incident field …

    strathclyde Repository record for Partial discharge behaviour under AC and DC conditions including novel manufacture techniques for void-type dielectric samples (opens in a new tab)

  14. Numerically efficient models of hybrid cascaded multilevel converters for high voltage direct current transmission system

    … while reducing carbon emissions. Voltage-source-converter-based high voltage direct current (VSC-HVDC) transmission is a critical enabling technology in integrating hydroelectric power, wind-power plants, and photovoltaic systems into the power grid. To further reduce converter losses and …

    ubc Repository record for Numerically efficient models of hybrid cascaded multilevel converters for high voltage direct current transmission system (opens in a new tab)

  15. Resilient Monitoring and Robust Control towards Blackout Prevention in Modern Power Grids

    … a futuristic grid comprised of Voltage Source Converter (VSC) based AC-MTDC is considered due to its recent proliferation in integrating offshore wind farms to onshore grids, and additionally improving strength of weak AC grids. A robust control is designed using the converter station poles as …

    ndsu Repository record for Resilient Monitoring and Robust Control towards Blackout Prevention in Modern Power Grids (opens in a new tab)

  16. Investigation of the effects of humidity and surface charge on partial discharge in insulator posts under DC voltage

    … and influence the reliability of the whole converter station and result in severe outages. It is believed that the flashover and partial discharge phenomena are strongly related to environmental conditions such as temperature, humidity, pressure, pollution's, and even space charges. The …

    manitoba Repository record for Investigation of the effects of humidity and surface charge on partial discharge in insulator posts under DC voltage (opens in a new tab)

  17. Optimal Planning for Wind Farm Collector System

    … the Fuzzy C-mean (FCM) clustering to locate substations and allocate turbines. Then a self-tracking minimum spanning tree (ST-MST) is proposed and used to track the connecting process, and this process is combined with added functions of automatic cable selecting (ACS) and cable crossing …

    unsw Repository record for Optimal Planning for Wind Farm Collector System (opens in a new tab)

  18. Model-Predictive Control of HVDC Grid

    … a control strategy for a Voltage-Sourced Converter (VSC)-based High-Voltage Direct-Current (HVDC)-grid. The envisioned control: (1) regulates and retains the HVDC-grid variables within their permissible ranges during transients and steady-state conditions; (2) shares control objectives …

    toronto-retro Repository record for Model-Predictive Control of HVDC Grid (opens in a new tab)

Page 1 of 2