Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 24 for “"Converter transformer"”
-
Space charge behaviour of thick oil and pressboard in a HVDC converter transformer
… system, the most significant apparatus is a HVDC converter transformer. In converter transformers, on the one hand, the high operational electric field is desirable to decrease the dimension, weight, and material usage in converter transformers; on the other hand, the electric field must be lower …
-
Space charge behaviour in thick oil pressboard insulation systems for converter transformers
… in the recent years. The reliability of the converter transformer, which is one the most important components in HVDC transmission, has become a general concern, because of its complex structure and operating conditions. It is well known that the presence of space charge can distort the …
-
Online partial discharge measurement in a high noise environment
… (PD) in a high-voltage direct current (HVDC) converter station. The HVDC station is a particularly challenging environment for PD measurement due to elevated interference levels caused from the switching of the thyristor-controlled converters. Online PD measurements are performed on two …
-
Incremental fuzzy PI control of a HVDC plant
… modeled with the detailed representation of the converter, converter transformer and AC/DC filters etc. The DC current error and its derivative are taken as two parameters necessary to adapt the proportional (P) and integral (I) gains of the current controller based on fuzzy reasoning.
-
Aspects of conversion of the Nelson River bipole 2 HVDC converters from 12-pulse to 6-pulse operation
… confronted with a serious problem involving the converter transformers for the bipole 2 operation of the Nelson River HVDC transmission system. The transformer problem left the negative pole of bipole 2, pole 3, without a converter transformer at each converter station. Since the transformer …
-
Series operation of thyristors in HVDC converters
… arcback, which requires special bracing for the converter transformer. In addition, mercury arc valves need considerable auxiliaries, including cooling and vacuum plants. Research and development directed towards the improvement in the voltage and current capabilities of thyristors are yielding …
-
Series operation of thyristors in HVDC converters
… arcback, which requires special bracing for the converter transformer. In addition, mercury arc valves need considerable auxiliaries, including cooling and vacuum plants. Research and development directed towards the improvement in the voltage and current capabilities of thyristors are yielding …
-
A Control Scheme for an AC-DC Single-Stage Buck-Boost PFC Converter with Improved Output Ripple Reduction
AC-DC power factor correction (PFC) single-stage converters are attractive because of their cost and their simplicity. In these converters, both PFC and power conversion are done at the same time using a single converter that regulates the output. Since they have only a single controller, these …
-
Measurement of ion mobility in dielectric liquids
… energy transfer in this technology is HVDC converter transformer. The insulation system of HVDC converter transformers, which basically consists of oil and paper/pressboard with different dielectric properties, needs to withstand AC and DC stresses. In particular for the UHVDC application …
-
Sub-synchronous interactions in a wind integrated power system
… drive train model, rotor and grid side converter controller models, converter transformer model and the pitch controller model. To accurately capture the effects of sub-synchronous interactions, the ac network is modelled using dynamic phasors. It is shown that using the proposed …
-
HARMONIC VOLTAGE PROFILE CALCULATIONS OF ELECTRIC POWER TRANSMISSION SYSTEMS
… harmonics. A dynamic model of a six pulse ac/dc converter is presented and the effect of the impedance of the converter transformer on the commutation delay is included to accurately determine the harmonic spectrum of the line current of the converter. The phase shifting behaviour of the …
-
HARMONIC VOLTAGE PROFILE CALCULATIONS OF ELECTRIC POWER TRANSMISSION SYSTEMS
… harmonics. A dynamic model of a six pulse ac/dc converter is presented and the effect of the impedance of the converter transformer on the commutation delay is included to accurately determine the harmonic spectrum of the line current of the converter. The phase shifting behaviour of the …
-
Modeling, Control, and Benchmarking of Multiple Modular VSC Topologies in Multiterminal DC-Grids
… energy resources. Modular voltage source converters (VSCs)-based high-voltage direct-current (HVDC) systems and multiterminal HVDC (MTDC) systems can fulfill these requirements improving the reliability of power systems. This transition may eventually lead to global super-grids consisting …
-
Graph-Based Power Flow Solution Methods for Electric Power Systems
… sides sequentially while employing the detailed converter model, including the converter transformer, filter, and the converter loss parameters for converter power loss calculations. The proposed method is validated using standard hybrid 5-bus and CIGR´E-B4-DC systems. The performance of the …
-
Numerical analysis and model order reduction for insulation evaluation of converter transformers
La sécurité de l'isolation des transformateurs convertisseurs est d'une grande importance pour le fonctionnement fiable du réseau électrique. Transformateurs convertisseurs fonctionnent dans des conditions de champ électrique intense, où les effets de couplage ont un impact significatif sur les …
-
Spínaný napájecí zdroj
Náplní této práce je navrhnout obvodové řešení zdroje napětí pomocí topologie Push-pull. Práce popisuje teoretické základy dané problematiky s návazností na reálný návrh a výpočet obvodových prvků.
-
Stejnosměrný výkonový zdroj
Tato diplomová práce se zabývá návrhem stejnosměrného výkonového zdroje, který bude sloužit pro technologické procesy ve strojírenské výrobě. V práci je zahrnut návrh jednotlivých komponent zdroje včetně řídících obvodů. Výstupní parametry výsledného zařízení budou následně ověřeny pomocí měření.
-
Výkonový měnič pro svařování stejnosměrným proudem
Práca bola zameraná na návrh a realizáciu výkonového meniča, ktorý mal pracovať ako zváračka. Bolo potrebné vybrať vhodný typ meniča. Následne bolo potrebné navrhnúť impulzný transformátor, výstupnú filtračnú tlmivku, dimenzovať polovodiče nachádzajúce sa v silovej časti zváračky. Navrhnuté boli …
-
Střídač pro jednofázovou ostrovní síť DC/AC 12/230 V
Tato práce se zabývá výběrem a konstrukcí střídače napětí z 12 V stejnoměrného napětí na 230 V/50 Hz střídavého napětí pro napájení spotřebičů do maximálního výkonu 250 W. Jako řídící obvod byl použit IO TL494CN. Součástí zařízení je též podpěťová ochrana střídače při poklesu napětí akumulátoru a …
-
AC/DC výkonový regulovatelný měnič 5 - 30 V / 30 A
Práce se zabývá spínanými zdroji, možnostmi jejich řešení a následně návrhem zdroje zadaných parametrů. V teoretické části se je rozebrána funkce spínaných zdrojů, přehledy zapojení AC/DC měničů a jejich vlastnosti. V rámci praktické části byl vyvinut výkonový AC/DC spínaný zdroj s nastavitelným …
Page 1 of 2