Experimental Evaluation of Innovative Thermal Energy Storage Options for a Hypersonic Non-Airbreathing Vehicle's Internal Loads
… of thermoelectric generators (TEGs) and a local coolant loop are investigated. The advantage of the former is that they transform waste heat into usable electricity, reducing the amount of thermal energy that needs to be stored by the heat sink. The advantage of the latter is that it results in a …
-
Assessing and Improving the State Simulation Accuracy of a 1D Electric Vehicle Thermal Management System Model
… tested for accuracy. Specifically, the battery coolant loop and the electric machine coolant loop is analyzed in this study. Components within these subsystems, including the battery, electric machine (EM), coolant pipes, heat exchanger, and DCDC converter, are evaluated for state simulation …
-
System Level Thermal Hydraulic Performance of Water-Based and PAO-Based Alumina Nanofluids
… by conventional theory. In this study, a coolant loop apparatus was designed and built to evaluate the laminar and turbulent heat transfer performance of water-based and PAO-based alumina nanofluids in a flowing system. Alumina/water solutions showed an increase in pressure drop with …
-
Modular modeling
… in a typical pressurized water reactor coolant loop. The lumped parameter modeling approach was used to develop the theoretical models. The driver functions to merge the simulator and theoretical models in the library into one large file.</p> <p>The Modular Modeling Program provides the …
-
Modeling of Mobile Air Conditioning System
… and reduce the refrigerant charge, a secondary loop system with coolant loop on both condenser and evaporator side was proposed. The performances of this system using R-134a, R-152a, and R-1234yf were evaluated and compared to that of conventional direct expansion system using R-134a under the …
-
Study on linking a SuperCritical water-cooled nuclear reactor to a hydrogen production facility
… integrated at several locations on an SCW NPP coolant loop. Using various test cases, design and operating parameters are recommended for detailed future research. In addition, predicted effects of heat transfer enhancement on HX parameters are evaluated considering theoretical improvements …
-
Operational Characteristics of a Fission Gas Detector
… out of the fuel material, enter the reactor coolant as it flows past the fuel, and be carried from the reactor. The magnitude of the hazard thus created depends on the type of reactor, the reactor power, shielding of the coolant lines, and other factors. In a reactor where the coolant makes …
-
Design Options for Ultra-compact Nuclear Driven Power Sources for Field Applications
… the first minutes of a Depressurization Loss of Coolant Accident scenario. For both the open and closed Brayton cycle models, Argon-41 production is significant. However, in an open cycle mode, Argon-41 is unlikely to provide a harmful dose. In a closed cycle mode, Argon-41 may require some …
-
Modeling, Construction, and Validation of a Simulator for a Nuclear Process Control Test Facility
… by integrating component blocks into (i) primary coolant loop, (ii) secondary water loop, (iii) pressurized air loop, and (iv) some auxiliary loops within physical domains. The integration of components forms a mathematical matrix to represent underlying principles of the NPCTF. By employing an …
-
The influence of hole geometry and metering length on flm cooling effectiveness of laid-back fan-shaped holes in compressible high-speed flow conditions
… components. This study focuses on the impact of coolant hole geometry and metering length on cooling effectiveness, with experiments conducted on various configurations, including standard (7-7-7) and alternative geometries (18-18-1, 15-15-1, 25-25-0, and 12-12-12), across a range of pressure …
-
Experimental Design and Flow Visualization for the Upper Plenum of a Very High Temperature Gas Cooled for Computer Fluid Dynamics Validation
… gas reactor (HTGR) design to have a 1000 ^(0)C coolant outlet. This increases fuel efficiency and allows for other industrial applications. During the design process several studies are performed to develop safety codes for the reactor. One major accident of interest is the Pressurized …
-
Optimisation of a Low-Cost Production Automotive Engine for Range Extender Application in an Electric Vehicle
… of the engine, M/G and inverter unit in separate coolant circuits for the engine and generator. The APU produced a peak power of 22.78kW at 5100rpm. Best ESFC of 260g/kWh was measured at 2500rpm, and the ESFC remained below 270g/kWh across 2000 to 3500rpm at full load. The specific performance of …
-
Natural Circulation in the Upper Plenum of a Scaled Model of a Very High Temperature Reactor in the Event of Loss-of-Coolant Accident
… which will be commercialized in 2030. A loss-of-coolant accident (LOCA) is a major accident scenario in which the primary coolant loop is broken, resulting in a loss of forced circulation of helium into the reactor vessel. With the onset of natural circulation, coolant flow reverses and is driven …
-
Development of Hybrid Fuel Cell / Li-ion Battery Systems
… battery pack and fuel cell stack onto a single coolant loop is feasible. The system is tested against a range of operating conditions and its performance is discussed. These findings are expected to aid the transport industry in the transition to a zero emission future.
-
Development of a Thermal Control Model for an AWD Dual Electric Motor Setup Used for The EcoCAR EV Challenge
… up with the pressure drop of the new powertrain coolant loop. These components have specific thermal cooling requirements, necessitating the integration of a dedicated thermal management system. This system is crucial for preventing overheating and ensuring the maintenance of optimal operating …
-
Aircraft Thermal Management Using Loop Heat Pipes
… thesis was to determine the feasibility of using loop heat pipes to dissipate waste heat from power electronics to the skin of a fighter aircraft and examine the performance characteristics of a titanium-water loop heat pipe under stationary and elevated acceleration fields. In the past, it has …
-
APPLICABILITY OF COLD METAL TRANSFER FOR REPAIR OF DISSIMILAR METAL WELDS IN STAINLESS STEEL PIPING IN NUCLEAR POWER PLANTS
Corrosion resistant butt welds in nuclear coolant loop piping were made with the Ni-base alloy 600 family during their initial construction several decades ago. Time has proved this material selection to be inadequate for resisting stress corrosion cracking from the corrosive primary water …
-
Inverted Brayton Cycles for Exhaust Gas Energy Recovery
… is to reject as much heat as possible, a liquid coolant loop with inexpensive materials offers a relatively light-weight, cost-effective solution. In addition, although the IBC system is installed immediately downstream of the top cycle and utilizes the exhaust gases as the operating fluid, it is …
-
Experimental investigation of the performance of a fully cooled gas turbine vane with and without mainstream flow and experimental analysis supporting the redesign of a wind tunnel test section
This study focused on experimentally determining the cooling performance of a fully cooled, scaled-up model of a C3X turbine vane. The primary objective was to determine the differences in overall effectiveness in the presence and absence of a hot mainstream flowing over the vane. Overall …
-
Náhrada dožitých klasických jaderných reaktorů malými modulárními reaktory
Bakalářská práce se zabývá náhradou klasických dožitých jaderných reaktorů malými modulárními reaktory. Zkoumá se technická proveditelnost náhrady a její rozsah. Ověřuje se navržené technické řešení dle příslušných norem. Dále jsou vyhodnocena legislativní a ekonomická omezení. Pro náhradu je …