  1. Experimental characterization of the Hitrap Cooler trap with highly charged ions.

    The HITRAP (Highly charged Ions TRAP)facility is being set up and commissioned at GSI, Darmstadt. It will provide heavy, highly charged ions at low velocities to high-precision atomic physics experiments. Within this work the Cooler trap- the key element of the HITRAP facility was tested. The …

    heid-diss Repository record for Experimental characterization of the Hitrap Cooler trap with highly charged ions. (opens in a new tab)

  2. Developments for the HITRAP Cooler Trap and mass measurements around A = 96 at SHIPTRAP

    The HITRAP (Highly charged Ions Trap) facility is currently being set up and commissioned at GSI in Darmstadt. It will provide bunches of 10^5 heavy highly-charged ions, for example hydrogen-like uranium (U^91+), to high-precision atomic physics experiments. The ions are produced by the GSI …

    heid-diss Repository record for Developments for the HITRAP Cooler Trap and mass measurements around A = 96 at SHIPTRAP (opens in a new tab)

  3. Cooling of highly charged ions in a Penning trap for HITRAP

    The HITRAP (Highly charged Ions Trap) facility is being set up at GSI, Darmstadt. It will enable high-precision atomic physics investigations on heavy, highly charged ions at extremely low energies. Species up to U^92+ as well as radioactive nuclides will be produced at the GSI accelerator complex …

    heid-diss Repository record for Cooling of highly charged ions in a Penning trap for HITRAP (opens in a new tab)

  4. The g-Factor of Hydrogen-Like Heavy Ions as a Test for QED

    … of the g-factor of an ion inside a Penning trap serves as a stringent test of BS-QED. A bunch of heavy highly-charged ions are created and decelerated at the GSI-HITRAP facility. The bunch is finally captured and cooled to 4 Kelvin inside the Cooler trap. The cold ions are transported and …

    heid-diss Repository record for The g-Factor of Hydrogen-Like Heavy Ions as a Test for QED (opens in a new tab)

  5. A cooler Penning trap to cool highly charged radioactive ions and mass measurement of 24Al

    Penning trap mass spectrometry (PTMS) can be used to test the Standard Model (SM) and to answer the questions related to the origin and abundance of the elements in the universe. There are several facilities worldwide specialized in PTMS and some of them can measure the masses of isotopes with …

    manitoba Repository record for A cooler Penning trap to cool highly charged radioactive ions and mass measurement of 24Al (opens in a new tab)