Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 37 for “"Cooling units"”.
-
Integrated Control of Multiple Cooling Units
… power consumption can be decreased. Efficient cooling of data centres involves meeting temperature constraints while minimizing power consumption. By exploring the opportunities that may be available through controlling multiple cooling units, we can avoid issues such as overcooling (some parts …
-
Optimal use of mobile cooling units in a deep-level gold mine
… potential for optimisation is the use of mobile cooling units. These units are used as tertiary cooling and become inefficient as a result of harsh underground working conditions, corrosion and a general lack of maintenance. As a result, these inefficient mobile cooling units can negatively …
-
Techno-economic application of modular air cooling units for deep level mining at Mponeng
… This then necessitates the need for an effective cooling medium that not only has a great efficiency but should also be sustainable in the current economical environment faced with power supply shortages. Currently the advantages of ice are explored on Mponeng Below 120 level (120L) project with …
-
THERMAL-AWARE COOLING CONTROL AND WORKLOAD ASSIGNMENT FOR HETEROGENEOUS DATA CENTERS
… challenges. Information technology (IT) and cooling infrastructure are the major contributors to power consumption in data centers. Server over-cooling, inefficient power management of cooling units, and thermal-oblivious assignment of server workload are significant contributors to the …
-
Explosion Structures in Grande Ronde Basalt of the Columbia River Basalt Group, Near Troy, Oregon
… explosion structures can be divided into two cooling units. The first cooling units occupy troughs in the pre-eruption topography and are up to 10 meters thick. The second cooling units contain the explosion structures and are up to 100 meters thick. The thickness of flows that contain …
-
Areal Extent and Volumes of the Dinner Creek Tuff Units, Eastern Oregon Based on Lithology, Bulk Rock Composition and Feldspar Mineralogy
… as generic Miocene welded tuff as well as local units such as the "Mascall" or "Pleasant Valley" tuff of eastern Oregon to individual cooling units that comprise the newly redefined Dinner Creek Tuff, enclosing an area of ~25,000 km2. Areal extents defined in this study show that all outcrops now …
-
Numerical Modeling and Simulation for Analysis of Convective Heat and Mass Transfer in Cryogenic Liquid Storage and HVAC&R Applications
… and temperature for various stages of a proposed cooling cycle and the prediction of its effective operating term. A typical refrigerated warehouse with a set of ceiling type cooling units were modeled and simulated with both 2-D and 3-D models. It was found that if the cooling units are closer to …
-
Improving efficiency and resilience in large-scale computing systems through analytics and data-driven management
… hardware layers such as processors, network, and cooling units. This thesis claims that to improve robustness and efficiency of large-scale computing systems, significantly higher levels of automated support than what is available in today's systems are needed, and this automation should leverage …
-
Data-driven Modelling and Optimized Management of the District Cooling System and Thermal Energy Storage in Gothenburg
District cooling system (DCS) is a sustainable and cost-effective way to provide cooling energy in urban areas[1]. DCS is growing in Sweden due to the increase in cooling energy demand. In Gothenburg, an expansion of DCS will be done by installing more cooling units and a cold-water thermal energy …
-
Cost Optimization of Modular Data Centers
… different choices for subcomponents, such as cooling systems, enclosures and power systems, this is a non-trivial exercise, especially, considering the complex multiphysics interactions among components that drive system efficiency. For designing such DCs, there is no research available. …
-
A Petrochemical Study of Compositionally Zoned Ash-Flow Tuffs
… zoning occurs within the basal simple cooling units of two welded ash-flow tuff sheets, the Kneeling Nun and Caballo Blanco formations, in the Cobre Mountains of southwestern New Mexico. The sheets are on the southern edge of the Datil-Mogollon volcanic province. The Kneeling Nun (33.4 …
-
Arquitetura para monitoramento e detecção de Anomalias Acústicas em Data Centers
… signals to identify anomalous conditions in cooling systems and developed a modular acoustic monitoring architecture composed of four layers: acquisition, preprocessing, machine learning analysis, and integration with monitoring and alerting systems. The research was supported by a systematic …
-
Numerical model for analysis and control of the quality of bulk-stored grain using cold air
… of ventilated grain stores that enables optimal cooling strategies to be identified and developed. The model describes heat and mass transfer in two dimensions and it enables heat and mass transfer phenomena that occur in the boundary layers of grain stores to be examined in detail. This is …
-
Innovative Energy-Efficient and Sustainable Cooling Solutions: Hybrid Systems for Thermal Comfort and Refrigeration Applications
The increasing global demand for cooling due to urbanization and climate change highlights the urgent need for sustainable and energy-efficient solutions. This thesis explores innovative cooling systems that integrate solar energy, phase change materials (PCMs), thermoelectric modules, and advanced …
-
Προσομοίωση της κατεργασίας θερμής έλασης κραμάτων αλουμινίου με χρήση πεπερασμένων στοιχείων
… stability are summarized below: •The use of both cooling units will increase cooling efficiency. •By increasing the roll temperature will lead to a more thermally stable roll. As a result: oA more uniform heat extraction from the plate through the length can be achieved. oThe roll will be more …
-
Hotspot management to reduce energy consumption in containerised data centres
… assessments of airflow, heat transfer and cooling performance in containerised data centres. A parametric study of multiple Workload Distribution strategies was conducted to quantify their effects on hotspot formation, rack-level thermal behaviour, and cooling energy demand. Six workload …
-
DISTRIBUTED COOLING FOR DATA CENTERS: BENEFITS, PERFORMANCE EVALUATION AND PREDICTION TOOLS
… (2) operation. There are three conventional DC cooling architectures: (a) room-based, (b) row-based, and (c) rack-based. Architectures (b) and (c) allows a modular DC design, where the ITE is within an enclosure containing a cooling unit. Due to scalability and ease of implementation, …
-
Welding in pyroclastic deposits
… of strain in single pyroclastic flow cooling units are studied using physical property measurements. Combined with petrographic indicators, these measurements are used to develop a classification scheme for welding intensity. The scheme has eight indices, demarcated by specific …
-
Modelling of the thermal evolution of steel strips cooled in the hot rolling runout table
The controlled cooling of steel on the runout table has become a standard practice in the production of flat hot-rolled products, and since its introduction by BISRA in 1957, has been adopted because it is a vital tool in meeting the increasing demand of steels with better quality and higher …
Page 1 of 2