  1. Limitations of current cooling water treatment processes to control cooling water chemistry in wet cooled power plants

    In a coal-fired power plant, recirculating cooling water exchanges latent heat energy with the exhaust steam in the condenser and transports the heat to the cooling tower for evaporative cooling. The water lost in the evaporative cooling tower is continuously replenished by make-up water or …

    nwu-za Repository record for Limitations of current cooling water treatment processes to control cooling water chemistry in wet cooled power plants (opens in a new tab)

  2. Limitations of current cooling water treatment processes to control cooling water chemistry in wet cooled power plants

    In a coal-fired power plant, recirculating cooling water exchanges latent heat energy with the exhaust steam in the condenser and transports the heat to the cooling tower for evaporative cooling. The water lost in the evaporative cooling tower is continuously replenished by make-up water or …

    nwu-za Repository record for Limitations of current cooling water treatment processes to control cooling water chemistry in wet cooled power plants (opens in a new tab)

  3. Improving Photovoltaic Panel Efficiency by Cooling Water Circulation

    … (PV) panel power efficiency by employing a cooling system based on water circulation, which represents an improved version of water flow based active cooling systems. Theoretical calculations involved finding the heat produced by the PV panel and the circulation water flow required to remove …

    unt Repository record for Improving Photovoltaic Panel Efficiency by Cooling Water Circulation (opens in a new tab)

  4. Design and implementation of electric motor drive for automotive cooling water pump

    Cette thèse propose une méthode de planification de trajectoire pour le contrôle basé sur la platitude des entraînements PMSM pour les pompes à eau des véhicules électriques. Cette approche vise principalement à garantir que le courant du moteur PMSM reste dans les limites permises grâce à un …

    star-france Repository record for Design and implementation of electric motor drive for automotive cooling water pump (opens in a new tab)

  5. Evolution of a Cooling Water Treatment Program at a Chemical Processing Plant

    … a corrosion inhibitor in the open recirculating cooling tower system. After several months of operation, problems in the system made evident the fact that polyphosphate as a corrosion inhibitor was not acceptable. An organic corrosion inhibitor was substituted for the phosphate, resulting in …

    ucf Repository record for Evolution of a Cooling Water Treatment Program at a Chemical Processing Plant (opens in a new tab)

  6. An Integrated Solar Heat Pump System for Cooling, Water Heating and Drying

    … solar system has been developed to provide water heating, drying and air conditioning. Under the meteorological conditions of Singapore, a series of experiments were conducted to evaluate the system performance. The three applications can be served simultaneously or independently. A large …

    nus Repository record for An Integrated Solar Heat Pump System for Cooling, Water Heating and Drying (opens in a new tab)

  7. Energy-Water Nexus for Integrating Cooling Water with Dual-Purpose Heat Pumps

    … has also been a recognition that energy and water issues are intertwined. Addressing the shortages of water and energy in an integrated manner is key to economic development and social progress. Upon the use of once-through cooling water in power plants and industrial facilities, the …

    tamu Repository record for Energy-Water Nexus for Integrating Cooling Water with Dual-Purpose Heat Pumps (opens in a new tab)

  8. Asymmetric flow measurement in space constrained cooling water ducts using a traversing probe

    The aim of this research was to identity and recommend a type of flow measurement technique suitable for flow measurements in the CW ducts. After conducting a literature survey, the author restricted research to a local flow measuring technique as a result of physical constraints on site. In …

    cape-town Repository record for Asymmetric flow measurement in space constrained cooling water ducts using a traversing probe (opens in a new tab)

  9. MODEL BASED SYSTEMS ENGINEERING APPROACH FOR COLLABORATIVE REQUIREMENTS IN COOLING WATER SYSTEM DESIGN

    Evaluation of the manufacturing process industry confirms that there is still manual exchange of product data between design and procurement engineers and equipment suppliers. Manual data exchange incurs human error, increases the cost, and takes more time. Also manual data exchange prevents …

    maryland Repository record for MODEL BASED SYSTEMS ENGINEERING APPROACH FOR COLLABORATIVE REQUIREMENTS IN COOLING WATER SYSTEM DESIGN (opens in a new tab)

  10. The ultra-high lime with aluminum process for removing chloride from recirculating cooling water

    Chloride is a deleterious ionic species in cooling water systems because it is important in promoting corrosion. Chloride can be removed from cooling water by precipitation as calcium chloroaluminate using ultra-high lime with aluminum process (UHLA). The research program was conducted to study …

    tamu Repository record for The ultra-high lime with aluminum process for removing chloride from recirculating cooling water (opens in a new tab)

  11. The effects of dissolved solids in process cooling water and mine water on concrete corrosion.

    … the effects of the dissolved solids in process cooling water (pcw) and mine water (mw) on concrete corrosion. An experimental set up was designed to simulate the process in the cooling towers of Sasol (Pty) Ltd at Secunda. The investigation was carried out using Ordinary Portland Cement (OPC) …

    ukzn Repository record for The effects of dissolved solids in process cooling water and mine water on concrete corrosion. (opens in a new tab)

  12. An Advanced Methodology to Enhance Energy Efficiency and Performance in a Hospital Cooling-Water System

    … and quality. Due to the critical role of cooling-water systems, this thesis focuses on these installations that are vital for both the comfort they provide through airconditioning and for healthcare activities. The objective of this research is to improve the performance of hospital …

    dialnet Repository record for An Advanced Methodology to Enhance Energy Efficiency and Performance in a Hospital Cooling-Water System (opens in a new tab)

  13. Analysis of the lime softening treatment process of industrial cooling water using MINTEQ geochemical model

    … softening treatment for the Saturn Corporation cooling tower in Spring Hill, Tennessee. The MINTEQ geochemical equilibrium model was used to simulate hydrated lime and soda ash addition to the make-up water in a clarifier. Model predictions of precipitates and clarifier effluent species …

    ut-knoxville Repository record for Analysis of the lime softening treatment process of industrial cooling water using MINTEQ geochemical model (opens in a new tab)

  14. Effect of biomolecules adsorption on oxide layers developed on metallic materials used in cooling water systems

    Cette thèse s'inscrit dans le cadre du projet européen BIOCOR ITN. Les matériaux métalliques habituellement utilisés dans les circuits de refroidissement de centrales électriques peuvent être affectés par la biocorrosion. L'objectif de ce travail était d'étudier l'influence de l'adsorption de …

    star-france Repository record for Effect of biomolecules adsorption on oxide layers developed on metallic materials used in cooling water systems (opens in a new tab)

  15. The fish populations of the Lower Forth Estuary, including the environmental impact of cooling water extraction

    … of the lower Forth Estuary, east Scotland. Cooling water extraction by the 2400 MW Longannet Power Station (LPS) inevitably removes a certain quantity of fish from the estuary, all of which experience mortality. The present study employed a sampling regime of greater intensity than previous …

    stirling Repository record for The fish populations of the Lower Forth Estuary, including the environmental impact of cooling water extraction (opens in a new tab)