Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 47 for “"Corneal Topography"”.

  1. Measurement of corneal topography and transparency

    Measurement of Corneal Topography and Transparency. A new method is described for measuring and modelling corneal topography. The method does not make assumptions about the underlying corneal shape and calculates radius of curvature at any point on the surface. This allows derivation of apex …

    city-london Download PDF for Measurement of corneal topography and transparency (opens in a new tab)

  2. An accessible approach for corneal topography

    Corneal topography consists of measuring the corneal shape, which is a key factor for visual acuity. The exam is used, for instance, in keratoconus detection, personalized contact lens fitting, in pre- and post-procedures associated with refractive surgery and corneal transplants. This thesis …

    brazil-ufrgs Repository record for An accessible approach for corneal topography (opens in a new tab)

  3. Interferometer for Measuring Dynamic Corneal Topography

    … to possess an instrument that can measure the corneal shape and tear film surface with the same accuracy and resolution that is currently performed on common optical elements. A dual interferometer system for measuring the dynamic corneal topography is designed, built, and verified. The …

    arizona-thes Repository record for Interferometer for Measuring Dynamic Corneal Topography (opens in a new tab)

  4. Corneal Topography Measurements for Biometric Applications

    … This project explores the possibility of using corneal topography measurements as a trait for biometric identification. Two new corneal topographers were developed for this study. The first was designed to function as an operator-free device that will allow a user to approach the device and have …

    arizona-thes Repository record for Corneal Topography Measurements for Biometric Applications (opens in a new tab)

  5. Rapid sequential corneal topography evaluation of selective suture removal in the management of post-keratoplasty astigmatism

    Penetrating keratoplasty is a full-thickness corneal transplant procedure with a relatively long post-operative visual rehabilitation period. Post-operative corneal astigmatism often causes refractive error resulting in suboptimal vision, despite a clear graft. In order to reduce this issue, …

    bu Repository record for Rapid sequential corneal topography evaluation of selective suture removal in the management of post-keratoplasty astigmatism (opens in a new tab)

  6. Ragenos topografija ragenos ligų diagnostikoje /

    … shape can significantly affect visual function. Corneal topography is a non-invasive method that enables the assessment of these changes and helps diagnose corneal diseases, particularly ectatic conditions. With advances in imaging technologies, corneal topography and tomography are becoming …

    vilnius Repository record for Ragenos topografija ragenos ligų diagnostikoje / (opens in a new tab)

  7. Μελέτη της επαναληψιμότητας μετρήσεων τοπογραφικών συστημάτων του κερατοειδούς στην οφθαλμολογία

    … software tool for the detailed presentation of corneal topography measurements variability by means of color coded maps. Methods. Software was developed in Visual Basic to analyze and process a series of 10 consecutive measurements obtained by a topographic system on calibration spheres and …

    greece Repository record for Μελέτη της επαναληψιμότητας μετρήσεων τοπογραφικών συστημάτων του κερατοειδούς στην οφθαλμολογία (opens in a new tab)

  8. A portable and low-cost corneal topographer design

    Corneal topography is an important tool for understanding and assessing one’s visual acuity. However, acquiring this information is not simple, and normally requires an instrument called corneal topographer. In this thesis, we present an in-depth pipeline for building a portable and low-cost …

    brazil-ufrgs Repository record for A portable and low-cost corneal topographer design (opens in a new tab)

  9. BIOMECHANICAL ALTERATION OF CORNEAL MORPHOLOGY AFTER CORNEAL REFRACTIVE THERAPY

    … Although orthokeratology (non-surgical corneal reshaping, Corneal Refractive Therapy, CRT®) has been used for almost a half century, contemporary CRT's outcomes and mechanisms still require investigation. A series of studies was designed to examine different aspects of non-surgical …

    waterloo Repository record for BIOMECHANICAL ALTERATION OF CORNEAL MORPHOLOGY AFTER CORNEAL REFRACTIVE THERAPY (opens in a new tab)

  10. Myopia control using orthokeratology

    … conditions due to the increase of aberrations. Corneal topography has become an integral part of ortho-k clinical practice. To be able to fit, design or monitor changes in ortho-k lens wearers, accurate corneal shape data from topographical maps are required. Agreement between the Aladdin …

    city-london Download PDF for Myopia control using orthokeratology (opens in a new tab)

  11. Modelling outcomes from orthokeratology

    … method for calculating anterior and posterior corneal topography. The novel calculation method was then used to evaluate the influence of orthokeratology (OK) lens wear and overnight edema on posterior corneal shape, and to develop a physical model for anterior and posterior corneal shape …

    unsw Repository record for Modelling outcomes from orthokeratology (opens in a new tab)

  12. Serial evaluation of corneal transplants

    … over time. The two variables studied were corneal topography and corneal touch sensitivity. Keratographs were obtained using the Photo Electronic Keratograph (PEK). An analysis technique was developed which enabled clinically meaningful topographical components to be derived from …

    city-london Download PDF for Serial evaluation of corneal transplants (opens in a new tab)

  13. Biomechanics of the eye in health and disease

    … but was not limited to: slit-lamp biomicroscopy, corneal topography, and the CorVis ST. Results An in vivo collateral globe displacement occurs when a short-acting air-pulse is applied onto the cornea. The separated corneal and orbital components of this overall displacement were isolated through …

    auckland-ms Repository record for Biomechanics of the eye in health and disease (opens in a new tab)

  14. Analysis of Corneal Topographic Optical Zone and Decentration after Myopic Refractive Surgery

    … degree of decentration were determined through corneal topography. We divide the eyes with the degree of decentration. Lesser than 0.5mm were classified as the first group, from 0.5 to 1.0mm were classified as the second group. The ablation zone diameter in topography was compared with …

    ajou Repository record for Analysis of Corneal Topographic Optical Zone and Decentration after Myopic Refractive Surgery (opens in a new tab) Embargoed until 9999-12-31

  15. Laser scanning in vivo confocal microscopy of corneal microstructure in inherited and acquired corneal disease

    … the in vivo cornea, allowing fresh insight into corneal microstructure in health and in inherited and acquired corneal disease. Recently, the introduction of laser scanning IVCM has utilised point scanning with coherent light to push forward the boundaries of real-time in vivo imaging. This …

    auckland-ms Repository record for Laser scanning in vivo confocal microscopy of corneal microstructure in inherited and acquired corneal disease (opens in a new tab)

  16. Evaluation of videokeratoscopy

    … increasingly popular in the investigation of corneal topography. The accuracy and repeatability of these instruments has been assessed mainly using spherical surfaces, however, few studies have assessed the performance of videokeratoscopes in measuring convex aspheric surfaces. Using two …

    aston Download PDF for Evaluation of videokeratoscopy (opens in a new tab)

  17. Implante de segmentos Intraestromales y Crosslinking acelerado en el tratamiento del Queratocono pediátrico

    … pediatric Keratoconus (KC) treatment with Intracorneal Ring Segment Implantation (ICRS) and accelerated Crosslinking (CXL). Methods: Descriptive observational study, were medical records of Fundonal patients in Bogotá, Colombia were reviewed. Children under 18 years with a history of KC who …

    rosario Repository record for Implante de segmentos Intraestromales y Crosslinking acelerado en el tratamiento del Queratocono pediátrico (opens in a new tab)

  18. Αντικειμενική αξιολόγηση της δυσφορίας θάμβους σε νοσήματα του πρόσθιου ημιμορίου του οφθαλμού

    … luminance using the subjective de Boer scale. Corneal topography-based wavefront analysis, pupil size, and angle kappa were calculated to identify possible significant correlations. Results: Mean values of discomfort glare for the patients’ group were 1.66 (SD 1.5) at 500 lx, 2.7 (SD 1.68) at …

    greece Repository record for Αντικειμενική αξιολόγηση της δυσφορίας θάμβους σε νοσήματα του πρόσθιου ημιμορίου του οφθαλμού (opens in a new tab)

  19. Επίδραση της βοηθητικής τομής (sideport) στη διάθλαση του οφθαλμού μετά από επέμβαση καταρράκτη

    Purpose: To study the changes in corneal astigmatism after cataract surgery when the sideport incision is performed at a predetermined location away from the tunnel incision. Materials and methods: A total of 333 eyes with corneal astigmatism ≤1.5 diopters (D) underwent cataract surgery. A …

    greece Repository record for Επίδραση της βοηθητικής τομής (sideport) στη διάθλαση του οφθαλμού μετά από επέμβαση καταρράκτη (opens in a new tab)

Page 1 of 3