Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 26 for “"Correlated double sampling (CDS)"”

  1. A transducer for tomograph imaging applications

    … capacitive transducer, which employs the correlated double sampling (CDS) technique to reduce the dc offset and 1/f noise of the CMOS amplifier, is proposed.

    nanyang Repository record for A transducer for tomograph imaging applications (opens in a new tab)

  2. A monolithic capacitive transducer for electrical capacitance tomography

    … being a critical building block, adopts correlated double sampling (CDS) to minimize the 1/f noise and cancel the dc offset arising from the dedicated op-amp having a high power-bandwidth efficiency. Moreover, it realizes a new instrumentation-based methodology through additional …

    nanyang Repository record for A monolithic capacitive transducer for electrical capacitance tomography (opens in a new tab)

  3. Electrochemical and optical CMOS sensors design for biochemical detection

    … to realize a high-sensitivity detection. Correlated double sampling (CDS) and pixel calibration are employed to reduce the variations in an array. The demonstrated CMOS biosensors are low-cost and miniaturized. They could become promising in personalized biomedical tests in future.

    nanyang Repository record for Electrochemical and optical CMOS sensors design for biochemical detection (opens in a new tab)

  4. Analysis and design of a CMOS sample-and-hold circuit for biomedical applications

    … lowpower circuit architecture that makes use of Correlated Double Sampling (CDS) is proposed. In along with ultra low-power op-amp, the circuit can be applied for ultra lowpower biomedical applications. Circuit operation and analysis of imperfect compensation have been presented. Not only does it …

    nanyang Repository record for Analysis and design of a CMOS sample-and-hold circuit for biomedical applications (opens in a new tab)

  5. A Multi-functional Touch Panel for Multi-Dimensional Sensing in Interactive Displays

    … have been developed and implemented. With correlated double sampling (CDS) and spatial low-pass filtering (SLPF) based techniques, the signal-to-noise ratio (SNR) of the capacitive touch signal is boosted by 15.6 dB, indicating improved detection accuracy. In terms of the readout speed, …

    cambridge Repository record for A Multi-functional Touch Panel for Multi-Dimensional Sensing in Interactive Displays (opens in a new tab)

  6. A Mixed-Signal Low-Noise Sigma-Delta Interface IC for Integrated Sub-Micro-Gravity Capacitive SOI Accelerometers

    … low-frequency noise reduction through the use of correlated double sampling (CDS) scheme. In this work, the measured resolution of the closed-loop CMOS-SOI accelerometer system, in the presence of high background accelerations, is in the micro-g (g: gravity) range. In this design, a second-order …

    gatech Repository record for A Mixed-Signal Low-Noise Sigma-Delta Interface IC for Integrated Sub-Micro-Gravity Capacitive SOI Accelerometers (opens in a new tab)

  7. CMOS image sensor with bi-directional column sensor

    … has been due to fixed-pattern noise reduction. Correlated double sampling (CDS) is a popular technique to reduce the effects of this source of noise. The circuitry required to implement CDS can be complex and hinders other areas of an image sensor performance in some schemes. This thesis …

    rit Repository record for CMOS image sensor with bi-directional column sensor (opens in a new tab)

  8. A high dynamic range CMOS image sensor with analog implementation of gamma correction

    … noise (FPN) is eliminated by an area efficient correlated double sampling (CDS) circuit. Finally, a non-linear voltage-controlled-oscillator based analog-to-digital converter (VCO-based ADC) merges the analog gamma correction with AD conversion. In addition, in this research a hot pixel …

    hkust Repository record for A high dynamic range CMOS image sensor with analog implementation of gamma correction (opens in a new tab)

  9. Investigation into Noise and Stability Effects on CCD and Readout Electronics with Reference to the PLATO Mission

    … effects with respect to ChargeCoupled Devices (CCDs), CCD camera readout electronics and Light-Emitting Diodes (LEDs). In Chapter 1 a general overview of CCD technology and description of the various detector types and their parameters is given, followed by a brief review of the planet finding …

    ucl Repository record for Investigation into Noise and Stability Effects on CCD and Readout Electronics with Reference to the PLATO Mission (opens in a new tab)

  10. A Highly-Sensitive Global-Shutter CMOS Image Sensor with On-Chip Memory For Hundreds of Kilo-Frames Per Second Scientific Experiments

    … capacitors. A 6T front-end is followed by a Correlated Double Sampling (CDS) circuitry that includes 2 capacitors and a reset switch. The 4T back-end circuitry consists of a source follower, in-pixel current source and 2 switches. The pixel design is unique because of the following. In a …

    unlv Repository record for A Highly-Sensitive Global-Shutter CMOS Image Sensor with On-Chip Memory For Hundreds of Kilo-Frames Per Second Scientific Experiments (opens in a new tab)

  11. High-temperature Bulk CMOS Integrated Circuits for Data Acquisition

    … IC includes a sigma-delta modulator with correlated double-sampling (CDS) pre-amplifier, a stand-alone sigma-delta modulator, constant-gm biasing circuit, oscillator and internal thermometer circuit. The CDS pre-amplifier has an adjustable gain and digitally programmable offset …

    ohiolink Repository record for High-temperature Bulk CMOS Integrated Circuits for Data Acquisition (opens in a new tab)

  12. An ASIC chip design with advanced image correction architectures for CMOS infrared imagers

    … image like automatic readout gain calibration, correlated double sampling (CDS), on-chip averaging, and dead pixel correction. The configuration memory holds 63x16 setting bits. The image memory has a size of 17x16x16 bits and is responsible for storing the final infrared image. The calibration …

    metu Repository record for An ASIC chip design with advanced image correction architectures for CMOS infrared imagers (opens in a new tab)

  13. Circuits and Systems for On-Chip RF Chemical Sensors and RF FDD Duplexers

    … oscillator and a reference oscillator where correlated double sampling (CDS) is used to mitigate the impact of flicker noise, temperature variations and frequency drifts. A prototype is implemented in 0.18 µm CMOS process with total chip area of 6.24 mm^2 to operate in 1-6 GHz range using …

    tamu Repository record for Circuits and Systems for On-Chip RF Chemical Sensors and RF FDD Duplexers (opens in a new tab)

  14. Low Power Analog to Digital Converters in Advanced CMOS Technology Nodes

    … FPN under bright illumination conditions, a double auto-zeroing (AZ) scheme is proposed. The proposed techniques are experimentally verified in a prototype chip designed and fabricated in the TSMC 40 nm low-power CMOS process. The PW technique saves 52.8% of power consumption in the hybrid …

    tamu Repository record for Low Power Analog to Digital Converters in Advanced CMOS Technology Nodes (opens in a new tab)

  15. Integrated low-power interfaces for impedimetric chemical sensors

    … analysis suggests that different types of noise (correlated or uncorrelated) dominate the noise performance in different measurement ranges and, thus, noise suppression techniques, such as chopper stabilization, correlated double sampling (CDS), and oversampling/averaging, are applied to adequate …

    gatech Repository record for Integrated low-power interfaces for impedimetric chemical sensors (opens in a new tab)

  16. Low-power ADC designs in scaled CMOS process

    … achieves 35.3dB SNDR and consumes 0.81mW while sampling at 700MS/s. (2) In the proposed continuous-time ∆Σ ADCs, conventional power-hungry opamp is replaced by voltage controlled oscillators (VCOs) that perform the data conversion in the phase domain instead of the voltage domain. In contrary to …

    texas Repository record for Low-power ADC designs in scaled CMOS process (opens in a new tab)

  17. Integrated three-axis accelerometers with nanometer scale capacitive gaps and signal conditioning interface IC

    … switched-capacitor (SC) interface circuit. Correlated double sampling (CDS) technique is introduced to eliminate inherent flicker noise of the amplifier, which is the dominant noise source of the circuit, and an extensive analysis was conducted to suppress other noise sources and attain high …

    gatech Repository record for Integrated three-axis accelerometers with nanometer scale capacitive gaps and signal conditioning interface IC (opens in a new tab)

  18. High-Speed Radhard Mega-Pixel CIS Camera for High-Energy Physics

    … block includes an analog time-interleaving (ATI) sampling circuit, a switched-capacitor programmable gain amplifier (SC-PGA), a 10-bit successive-approximation register (SAR) ADC, two 10-bit memory banks. The column-parallel SAR ADC is area-efficient to be laid out in half of one pixel pitch, 10 …

    unlv Repository record for High-Speed Radhard Mega-Pixel CIS Camera for High-Energy Physics (opens in a new tab)

  19. CMOS multimodal sensor based lab-on-a-chip system for personalized bio-imaging diagnosis

    … voltage mismatch or FPN is reduced by a correlated double sampling (CDS) readout circuit structure that supports both image and pH modes for large-array and high-throughput application. Measurement results show a sensitivity of 103.8mV/pH and FPN reduction from 4% to 0.3% with a readout …

    nanyang Repository record for CMOS multimodal sensor based lab-on-a-chip system for personalized bio-imaging diagnosis (opens in a new tab)