  1. GVWD corrosion control initiative, phase II: inhibitor chemical testing at Seymour Dam

    … District (GVRD) waters have some of the highest corrosion potentials in North America. A previous pilot study determined that copper corrosion could be reduced by 60 to 80 percent and lead corrosion could be reduced by10 to 60 percent by disinfecting with chloramine instead of chlorine and by …

    ubc Repository record for GVWD corrosion control initiative, phase II: inhibitor chemical testing at Seymour Dam (opens in a new tab) Download PDF for GVWD corrosion control initiative, phase II: inhibitor chemical testing at Seymour Dam (opens in a new tab)

  2. Nanotechnology for corrosion control Silsesquioxane based nanofillers for iron carbonate film enhancement

    Carbon dioxide internal corrosion is one of the most common degradation mechanisms occurring in oil and gas exploration and production environments when carbon steel is the material of construction. Both general and localized attack can lead to severe production cuts and safety incidents and these …

    whiterose Download PDF for Nanotechnology for corrosion control Silsesquioxane based nanofillers for iron carbonate film enhancement (opens in a new tab)

  3. Evaluating Corrosion Control Alternatives For A Reverse Osmosis, Nanofiltration And Anion-exchange Blended Water Supply

    … in secondary impacts related to accelerated corrosion of distribution system components and subsequent regulatory compliance. In addition, replacement of the LS process altered the in-plant blending operations by creating an unstable intermediate blend composed of RO and IX waters. There were …

    ucf Repository record for Evaluating Corrosion Control Alternatives For A Reverse Osmosis, Nanofiltration And Anion-exchange Blended Water Supply (opens in a new tab)

  4. In-plant And Distribution System Corrosion Control For Reverse Osmosis, Nanofiltration, And Anion Exchange Process Blends

    … (SDWA). This is especially true with respect to corrosion control, since minor changes in water quality can affect metal release. Changes in metal release can have a direct impact on a water purveyor’s compliance with the SDWA’s Lead and Copper Rule (LCR). In 2010, the Town of Jupiter (Town) …

    ucf Repository record for In-plant And Distribution System Corrosion Control For Reverse Osmosis, Nanofiltration, And Anion Exchange Process Blends (opens in a new tab)

  5. Experimental Investigation of Nanofin Effect (Nfe) with Applications in Thermal Management and Corrosion Control Using Nanofluids

    … as agents for mitigating radiation and as corrosion inhibitors. On the other hand, the phenomenon of density enhancement in nanofluids can make them attractive candidates as prospective radiation shielding materials in space exploration missions. In this study, experimental validation of …

    tamu Repository record for Experimental Investigation of Nanofin Effect (Nfe) with Applications in Thermal Management and Corrosion Control Using Nanofluids (opens in a new tab)

  6. CORROSION CONTROL ON THE LVC GRID — PERSISTENT AUGMENTED AND VIRTUAL ENVIRONMENTS IN SUPPORT OF AIRCRAFT MAINTENANCE

    … display boards on the walls of maintenance control to desktop networked management tools, the introduction of a persistent augmented and virtual environment (PAVE) to aid MRO operations presents the next major milestone. This work proposes MRO on Deck, an expansion of the “smart hangar” …

    nps Repository record for CORROSION CONTROL ON THE LVC GRID — PERSISTENT AUGMENTED AND VIRTUAL ENVIRONMENTS IN SUPPORT OF AIRCRAFT MAINTENANCE (opens in a new tab)

  7. Design and evaluation of a continuous electrochemical purification reactor for corrosion control in flowing molten chloride salts

    … has been challenged due to the lack of corrosion control strategies at scale. This thesis evaluated an electrochemical purification reactor using Mg anodes and W cathodes to remove the corrosive impurity MgOHCl. A series of studies were conducted and assessed the feasibility of scaling …

    colo-mines Repository record for Design and evaluation of a continuous electrochemical purification reactor for corrosion control in flowing molten chloride salts (opens in a new tab)

  8. Bench- and Pilot-Scale Corrosion Control Inhibitor Effectiveness Studies for a Community's Blended Surficial and Brackish Groundwater Supply

    … four phosphate-based inhibitors were tested for corrosion control. Based on the initial screening results, the City challenged UCF to derive a cost-effective, bench-scale method that could mimic distribution system conditions and be used to assess treatment technology infrastructure changes on …

    ucf Repository record for Bench- and Pilot-Scale Corrosion Control Inhibitor Effectiveness Studies for a Community's Blended Surficial and Brackish Groundwater Supply (opens in a new tab)

  9. Assessing silica and dissolved oxygen effects on copper corrosion control in southern Nevada water treatment and supply system

    … to investigate both the effect of silica on the corrosion process in the water system, and the effect of increased oxygen concentration resulting from ozonation on copper corrosion in the water system. The piping system used in the pilot plant resembled a household piping system, and consisted of …

    unlv Repository record for Assessing silica and dissolved oxygen effects on copper corrosion control in southern Nevada water treatment and supply system (opens in a new tab) Download PDF for Assessing silica and dissolved oxygen effects on copper corrosion control in southern Nevada water treatment and supply system (opens in a new tab)

  10. LIMESTONE CONTACTORS AS A CORROSION CONTROL TECHNOLOGY FOR SMALL PUBLIC WATER SYSTEMS: An Educational Module for Drinking Water Professionals

    … and engineers of limestone contactors as a corrosion control method to meet the lead and copper action level stated in the U.S. EPA’s Lead and Copper Rule. This module includes the description of the processes involved in a limestone contactor, the criteria used in the design, operational …

    ut-knoxville Repository record for LIMESTONE CONTACTORS AS A CORROSION CONTROL TECHNOLOGY FOR SMALL PUBLIC WATER SYSTEMS: An Educational Module for Drinking Water Professionals (opens in a new tab)

  11. Lead and Copper Corrosion Control in New Construction: Shock Chlorination, Flushing to Remove Debris & In-line Device Product Testing

    … undesirable from health, aesthetic, and corrosion perspectives. Soldering flux is of particular concern due to its corrosive nature. Experiments were conducted to determine the effects of residual solder flux, PVC glue, and metallic debris and to quantify flushing velocities and durations …

    vt Repository record for Lead and Copper Corrosion Control in New Construction: Shock Chlorination, Flushing to Remove Debris & In-line Device Product Testing (opens in a new tab)

  12. Assessing the impact of corrosion control and increased dissolved oxygen levels on GVRD member municipality distribution and premise plumbing systems

    … out. The effectiveness of previously implemented corrosion control plans on the amount of observed metal concentration at the tap, in the warmest and coldest months of the year was evaluated. The effect of different primary disinfectants at the Seymour and Coquitlam water source was also …

    ubc Repository record for Assessing the impact of corrosion control and increased dissolved oxygen levels on GVRD member municipality distribution and premise plumbing systems (opens in a new tab) Download PDF for Assessing the impact of corrosion control and increased dissolved oxygen levels on GVRD member municipality distribution and premise plumbing systems (opens in a new tab)

  13. HOW IMPROVED CORROSION CONTROL PRACTICES IN THE U.S. NAVY'S ARLEIGH BURKE CLASS DESTROYER ENGINEERING SPACES MIGHT ENHANCE SHIP EFFICIENCY WHILE OPERATING

    This research attempted to answer how improved corrosion-control practices in the U.S. Navy’s Arleigh Burke Class Destroyer engineering spaces might enhance ship efficiency. It can be confidently stated that effective corrosion control in Arleigh Burke Destroyer engineering spaces clearly enhances …

    nps Repository record for HOW IMPROVED CORROSION CONTROL PRACTICES IN THE U.S. NAVY'S ARLEIGH BURKE CLASS DESTROYER ENGINEERING SPACES MIGHT ENHANCE SHIP EFFICIENCY WHILE OPERATING (opens in a new tab)

  14. Impact of Premise Plumbing Conditions, Materials, Corrosion Control, Temperature, and Water Heater System Design on the Growth of Opportunistic Pathogens in Drinking Water

    … lead exceeding the EPA limit of 15 µg/L after corrosion control was interrupted. Follow-up sampling events between August 2015 and August 2017 demonstrated that the switch back to the original water source and addition of enhanced corrosion control in October 2015, dramatically reduced lead, …

    vt Repository record for Impact of Premise Plumbing Conditions, Materials, Corrosion Control, Temperature, and Water Heater System Design on the Growth of Opportunistic Pathogens in Drinking Water (opens in a new tab)

  15. Phosphate use for Sequestration, Anti-Scaling, and Corrosion Control: Critical Review, Simultaneous Optimization of Polyphosphate Dosing, Sequestration Mechanisms, and Stabilization of Magnesium Silicate Scale

    … via threshold inhibition, and 3) reduce corrosion of pipes by forming protective pipe scales. Orthophosphates can control lead, copper and iron corrosion through the formation of durable, low solubility scale, but are widely believed ineffective for sequestration or anti-scaling. …

    vt Repository record for Phosphate use for Sequestration, Anti-Scaling, and Corrosion Control: Critical Review, Simultaneous Optimization of Polyphosphate Dosing, Sequestration Mechanisms, and Stabilization of Magnesium Silicate Scale (opens in a new tab)

  16. Novel Insights into Lead Corrosion Control: Safely Changing Source Waters, Effective Use of Zinc Phosphate Inhibitors, Electrochemical Reversal of Solder, and Significance of Lead-Polyphosphate Complexation

    … contamination events arising from lead solder corrosion have drawn attention to our alarmingly inadequate understanding of corrosion control chemistry. This dissertation provides novel contributions to an improved understanding of lead corrosion control in four sequential chapters that: 1) …

    vt Repository record for Novel Insights into Lead Corrosion Control: Safely Changing Source Waters, Effective Use of Zinc Phosphate Inhibitors, Electrochemical Reversal of Solder, and Significance of Lead-Polyphosphate Complexation (opens in a new tab)

  17. The most immediate and cost effective way to address vehicle corrosion in Hawaii

    … Within four years of this acquisition, a serious corrosion problem developed with the M900 series truck. Efforts to control this corrosion have proven to be unsuccessful. The current maintenance budget does not adequately fund the corrosion program nor are the facilities and procedures able to …

    nps Repository record for The most immediate and cost effective way to address vehicle corrosion in Hawaii (opens in a new tab)

  18. Waterborne Paint System Based on CeO2 and Polyaniline Nanoparticles for Anticorrosion Protection of Steel

    … the last 3 years in the Laboratory of Industrial Corrosion Control at the University of Trento. The subject is related to corrosion control through an organic coating paint system for steel substrates. In other words, it coveres the investigation of anticorrosive pigments as viable alternatives to …

    trento Repository record for Waterborne Paint System Based on CeO2 and Polyaniline Nanoparticles for Anticorrosion Protection of Steel (opens in a new tab)