Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 157 for “"Corrosion Inhibitor"”.
-
Corrosion Inhibitor for Potash Solution Mining
Corrosion has always been a costly operational problem in potash solution mining operations. With the aim of reducing operating cost, this work proposed to apply a corrosion inhibitor that is compatible to potash brine environments, less toxic than the base substrate potash, commercially available, …
-
Effects Of Orthophosphate Corrosion Inhibitor In Blended Water Quality Environments
… evaluated the effects of orthophosphate (OP) inhibitor addition on iron, copper, and lead corrosion on coupons exposed to different blends of groundwater, surface water, and desalinated seawater. The effectiveness of OP inhibitor addition on iron, copper, and lead release was analyzed by …
-
Structural performance evaluation of the Postrite post-treatment corrosion inhibitor system
… chlorides penetrate the concrete and initiate corrosion of the reinforcing steel. A proven corrosion inhibitor system, the Postrite Post-treatment System, used in reinforced concrete rehabilitation, employs the use of a spray treatment of Postrite (15% calcium nitrite by weight) onto the …
-
Flash heating of epoxy-based corrosion inhibitor thin films on aluminum substrates
… onto epoxy-polyamide primer which is used as a corrosion inhibitor coating. The thermal degradation initiation temperature of the epoxy polyamide film increased with increasing heating rates. This coating is a high solids epoxy primer manufactured by Deft Inc. A xenon flash lamp was focused to a …
-
Impact Of Corrosion Inhibitor Blended Orthophosphate On Water Quality In Water Distribution Systems
The impact of blended orthophosphate (BOP) inhibitor addition on the corrosion of iron, copper, and lead in drinking water distribution systems was studied under changing water quality environment. Release of iron, copper, and lead were monitored at varying inhibitor doses and changing blends of …
-
Performance of a penetrating corrosion inhibitor in controlling carbonation induced corrosion in reinforced concrete
Reinforcement corrosion in concrete remains the most serious cause of premature deterioration of concrete structures world-wide, and many methods have been proposed to combat this problem. One method of improving the durability of concrete in aggressive environments is the use of corrosion …
-
Effects of orocol TL (a corrosion inhibitor) on germination and growth of bush beans
… compound added to DOE cooling water systems for corrosion inhibition) at low and high concentrations in the soil by adjusting soil pH and the percent of organic matter.</p> <p>Germination effects were determined in bean plants grown in soils adjusted to differing pH ranges (4-4.5, 5-5.5, 6.5-7), …
-
Impact of Orthophosphate as a Corrosion Inhibitor and Chloramine Disinfectant on Drinking Water Biofilm Communities
… concerns. As lead service lines are common, corrosion inhibitors, such as orthophosphate, have been increasingly utilized by municipalities as a means of controlling lead solubility. However, the impact of these corrosion inhibitors on the microorganisms present in a DWDS is not fully …
-
Water Quality, Aesthetic, and Corrosion Inhibitor Implications of Newly Installed Cement Mortar Lining Used to Rehabilitate Drinking Water Pipelines
… the affects of three different phosphate-based corrosion prevention additive regimes were evaluated. Cement mortar leachates impacted water quality significantly during the first week of exposure. Alkalinity, hardness and pH increased dramatically after initial exposure, rising to approximately …
-
Effects Of Source Water Blending Following Treatment With Sodium Silicate As A Corrosion Inhibitor On Metal Release Within A Wat
… to investigate and quantify the effects of corrosion inhibitors on metal release within a pilot distribution system while varying the source water. The pilot distribution system consisted of pre-existing facilities from Taylor et al (2005). Iron, copper, and lead release data were collected …
-
A Thesis on the Interactions between Lead Pipe Scales and Dissolved Silica from the Addition of Sodium Silicate as a Corrosion Inhibitor
… convey, but the mechanism of silica uptake and corrosion control have not been reported. Knowledge of variables which affect the uptake of dissolved silica and the consumption rate of added sodium silicate by scales of corrosion products that are present on lead service lines will be useful to …
-
Επίδραση πρόσθετων στις επισκευές του οπλισμένου σκυροδέματος
… and experimental effects of additional corrosion inhibitors to protect the steel of reinforced concrete. The action and effectiveness of corrosion inhibitors is examined with the aid of laboratory corrosion test. Specifically, the design of the test procedure comprises two categories. In …
-
Evolution of a Cooling Water Treatment Program at a Chemical Processing Plant
… polyphosphate product was selected for use as a corrosion inhibitor in the open recirculating cooling tower system. After several months of operation, problems in the system made evident the fact that polyphosphate as a corrosion inhibitor was not acceptable. An organic corrosion inhibitor was …
-
The Simulation and Water Quality Characterization of a Coal Slurry Involving Eastern Coal
… depending upon the coal used and the use of a corrosion inhibitor. The coal-water interactions were evaluated in a pilot-plant closed-loop coal slurry pipeline. Pulverized coal from eastern Kentucky and tap water were slurred and pumped through a 40 foot (12.2 m) pipe loop for ten days. Slurry …
-
An electrochemical and surface analytical investigation of iron oxidation, passivation and corrosion inhibition
… of iron oxidation, passive film formation and corrosion inhibitor interaction is presented. Ultrahigh vacuum surface analysis by Auger electron spectroscopy (AES), low energy electron diffraction (LEED), thermal desorption mass spectrometry (TDMS) and ion bombardment (depth profiling) was used …
-
Corrosão do aço API K55 causada por salmouras de cloreto de sódio utilizadas na indústria de petróleo
… of sodium chloride, sodium bisulfite and corrosion inhibitor about the API K55 steel’s corrosion rate using a factorial design 2 4 with a central point and also verify the corrosion inhibitor’s efficiencies in the various brines’ compositions. Bases on NACE TM169, the corrosion rate tests …
-
Corrosion Inhibition Effect of Modified Surface via Nanocapsule Embedded Coating and Al-Si-Mg Coating
Corrosion of metals has been nominated as one of the major issues that contribute to material degradation which can ultimately trigger economic losses via unexpected accidents including material failure. The service period of metal can be extended by applying an either organic or inorganic coating. …
-
Functionalization of nanoclays through exchange reactions
… based ionic liquids (ILs) and a commercial corrosion inhibitor. Clay modification was examined by TGA, FTLR and WXRD. The cationic clay modified with both ILs had similar thermal stabilities since they contained the same cation although the original anions were different. The thermal …
-
Smart Coatings for Preemptive Corrosion Protection
… has been increasing interest on self-healing corrosion protection. High pH-responsive polymers (HPRP) have been designed and synthesized followed by the subsequent preparation of surfactant free HPRP particle dispersions (particle size ≤ 500 d.nm) from preformed polymer by a simple phase …
-
Performance Evaluation of Epoxy-Coated Reinforcing Steel and Corrosion Inhibitors in a Simulated Concrete Pore Water Solution
… from the coater's plant, three commercial corrosion inhibitors, and one ECR plus a corrosion inhibitor were evaluated as reinforcing steel corrosion protection systems against chloride induced corrosion. The three corrosion inhibitors were calcium nitrite, an aqueous mixture of esters and …
Page 1 of 8