Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 43 for “"Corrosion Monitoring"”.
-
UH-1 corrosion monitoring
… concern for their structural integrity. With corrosion damage becoming a bigger part of the sustainment picture with increasing maintenance burden and cost, it is becoming increasingly important for corrosion management to be updated with more advanced techniques. The current find-and-fix …
-
Long Period Grating-Based pH Sensors for Corrosion Monitoring
Corrosion related deterioration of aging aircraft has proven to cause reduced flight availability, service lifetime, costly repairs, and if undetected, can result in potentially unsafe operating conditions. The purpose of this research is to develop, fabricate and test optical fiber-based chemical …
-
Experimental Approach To Validate A Real-time Corrosion Monitoring System
Monitoring corrosion is a vital step to prevent catastrophic structural failure. With accurate corrosion rate data, one can mitigate the risk of failure by performing routine maintenance on components that have become compromised. This monitoring process becomes more complicated when the corroding …
-
Acoustoelasticity and data processing for acoustic-based corrosion monitoring in structures
Corrosion is one of greatest concerns in a variety structures, from cable-stayed and suspension bridges to prestressed and post-tensioned concrete members. The common theme in these structures is corrosion of the load-bearing steel strands. These members carry significantly larger stresses compared …
-
State Estimation and Economic Analysis for Electrochemical Sensor-Based Corrosion Monitoring
… Damage to equipment in power plants by corrosion is a leading cause of equipment failure and subsequent forced outage. This work primarily aims to estimate equipment corrosion and its remaining useful life using a nonlinear state estimator across multiple sensor networks. Subsequently, …
-
A Study of Corrosion Monitoring Techniques Used in URLs for Metals
… geological disposal will also be carried out. Corrosion of metallic materials, which are closely related to the safety of URL, is the focus of this research project. This study selected monitoring techniques for URL and developed a rough monitoring scheme for temperature and resistivity in URL. …
-
Real-Time Corrosion Monitoring and AI-Driven EIS Spectra Prediction for Aluminium Beverage Cans
… can-lids play a critical role in preventing corrosion and maintaining the integrity of the product throughout its shelf life. However, these coatings are susceptible to long-term degradation due to mechanical stresses during fabrication and the corrosive nature of various beverages. …
-
Improvement of the approaches to monitoring of reinforced concrete bridges subjected to chloride-induced reinforcement corrosion in bridge management systems
Reinforcement corrosion in reinforced concrete (RC) bridges has undeniably become the main cause of civil infrastructure durability problems in many countries. The steel reinforcing in concrete corrode when certain conditions (e.g., carbonation, chlorides, insufficient cover and moisture) are met. …
-
Monitoring Corrosion Of A One Inch Ball Valve In A Hydraulic Loop Using Ultrasonic Technology
… parts in the process chemical industry. While corrosion monitoring is widely studied, there is not much information available regarding corrosion monitoring of control valves, as referenced in the literature review for this dissertation. This research investigated some foundational blocks for …
-
The Application of Laser Induced Breakdown Spectroscopy to Molten Salt Corrosion
… These conditions lead to problems with corrosion. Monitoring of this corrosion will be required for a MSR when built. Laser Induced Breakdown Spectroscopy (LIBS) is an excellent tool for this application, as it can be done with minimal sample preparation and without having to complete …
-
Assessment of In-situ Corrosion Conditions at Nevada Mechanically Stabilized Earth Wall Sites: Using Electrochemical Soil Characteristics and Linear Polarization Resistance
… using metallic reinforcements (Thornley 2009). Corrosion of metallic elements a naturally occurring electrochemical process is irreversible an inevitable. The rate of metal loss (corrosion) is a function of the environmental conditions and metal type. For MSE walls key parameters include the …
-
Determining Seasonal Corrosion Rates in Ferrous-Hulled Shipwrecks : A Case Study of the USS Huron
… seasonal environmental factors that affect the corrosion rates of ferrous-hulled shipwrecks in an archaeological setting. The remains of USS Huron, a warship that sank off the coast of Nags Head, North Carolina in 1877 is used as a case study. This study correlates rates of corrosion to seasonal …
-
Real time nanogravimetric monitoring of corrosion in radioactive environments
Monitoring and understanding the mechanism of metal corrosion throughout the nuclear fuel cycle play a key role in the safe asset management of facilities. They also provide information essential for making an informed choice regarding the selection of decontamination methods for steel plant and …
-
NONDESTRUCTIVE INSPECTION OF CORROSION AND DELAMINATION AT THE CONCRETE-STEEL REINFORCEMENT INTERFACE
… the feasibility of detecting and quantifying corrosion and delamination (physical separation) at the interface between reinforcing steel bars and concrete using ultrasonic guided waves. The problem of corrosion of the reinforcing steel in structures has increased significantly in recent years. …
-
Image Analysis Of Corrosion Pit Initiation On ASTM Type A240 Stainless Steel And ASTM Type A 1008 Carbon Steel
The adversity of metallic corrosion is of growing concern to industrial engineers and scientists. Corrosion attacks metal surface and causes structural as well as direct and indirect economic losses. Multiple corrosion monitoring tools are available although those are time-consuming and costly. Due …
-
Fabrication of Functionalized Graphene Coated OTFT Humidity and Chloride Ion Sensors for Detecting Corrosion Precursors in Metallic Structures
Corrosion monitoring has been the focus of structural health monitoring due to its damaging effects on metallic structures. Early detection of environmental factors responsible for corrosion can reduce maintenance related expenses. There is growing interest in developing compact and low-cost thin …
-
Condition Monitoring of Pipelines
… as vibrational fatigue, thermal fatigue, and corrosion. Monitoring the condition of such equipment is critical for its continued safe operation. Monitoring permits operators not only to assess the accumulated damage caused by system operation, but also to identify and avoid or minimise those …
-
Tribocorrosion of total hip replacements
… the complex interactions between wear and corrosion (termed tribocorrosion) and leads to the production of metallic particulate debris and metallic ions. The interaction of these degradation products with the body can lead to serious health complications, within patients, and is an …
-
Probability of Detection for Corrosion-induced Mass Loss and Yield Strain in Metal Structures Using Fe-C Coated Long Period Fiber Gratings Sensors and Electroresistive Strain Gauges
… were evaluated under natural and accelerated corrosion conditions with temperature compensation. Due to high conductivity, mechanical stability, and chemical sensitivity, MXene-based corrosion sensors revealed more consistent wavelength-mass correlations than graphene-based sensors. When …
-
Corrosion detection using metal coatings on fiber optic sensors
Fiber optic sensors have been utilized as corrosion sensors by depositing metal coatings to the surface of the sensors. Three types of fiber optic sensors were investigated as candidates for corrosion detection: the extrinsic Fabry-Perot interferometer (EFPI), the absolute extrinsic Fabry-Perot …
Page 1 of 3