Results 1 to 20 of 121 for “"Coulter Counter"”

  1. Resolving bacteria with the coulter counter

    … of counting and sizing of bacteria with the Coulter Counter and to evaluate orifices which were prepared in this laboratory. Size distributions of Pasteurella multocida and Proteus vulgaris were obtained with the electronic particle counter. These distributions appeared to follow the normal …

    vt Repository record for Resolving bacteria with the coulter counter (opens in a new tab)

  2. A MEMS based Coulter counter for cell sizing

    … the design and fabrication of a MEMS based Coulter counter for monitoring cellular volumetric changes after an exposure to various media. The device is based on three important phenomena: 1) Passive mixing of the reagents, 2) Dielectrophoretic focusing of the cells and 3) Electrical …

    missouri Repository record for A MEMS based Coulter counter for cell sizing (opens in a new tab)

  3. MEMS Coulter counter for dynamic impedance measurement of time sensitive cells

    … AT AUTHOR'S REQUEST.] In this research, a MEMS Coulter counter is designed, modeled, fabricated and characterized, which can detect and monitor the dynamic cell impedance changes in situ as a function of time and cellular volumetric changes after mixing isolated cell populations with different …

    missouri Repository record for MEMS Coulter counter for dynamic impedance measurement of time sensitive cells (opens in a new tab)

  4. Best Practices for Asphalt Emulsion Particle Size Analyses Using a Coulter Counter

    … particle size analyses, specifically with a Coulter counter. Data collected from eight emulsions was analyzed, and a recommended procedure for testing and analyzing particle size results using a Coulter counter was produced in the form of a draft ASTM specification. RStudio was used to …

    arkansas Repository record for Best Practices for Asphalt Emulsion Particle Size Analyses Using a Coulter Counter (opens in a new tab)

  5. Salmonella Detection by Coulter Counter Volume Displacement Using Specific Antibody Coated Latex

    … study was designed to determine whether this Coulter Counter for detection of Salmonella typhimurium cells. The latex particles are coated with a specific antiserum which reacts with the particulate antigen, Salmonella cells. An increase in the volume of latex antibody and Salmonella cells is …

    sdstate Repository record for Salmonella Detection by Coulter Counter Volume Displacement Using Specific Antibody Coated Latex (opens in a new tab)

  6. Modeling of Ion Transport for Micro/Nano Size Particles in Coulter Counter Application

    Coulter Counter (CC) is a device for counting small particles by recording the electrical current change during the translocation of the particle through a small pore. By counting the number of pulses in the measured current signal, the number of particles in the solution can be determined. The …

    ohiolink Repository record for Modeling of Ion Transport for Micro/Nano Size Particles in Coulter Counter Application (opens in a new tab)

  7. A High throughput parylene microchannel coulter counter for cell sizing and cell counting applications /

    … cell counting and sorting is carried out by Coulter Counter devices, in which the electrical potential or resistance change is measured when the cells flow through the defined aperture. Coulter Counter devices perform rapid and accurate analysis of the biological particles in terms of their …

    metu Repository record for A High throughput parylene microchannel coulter counter for cell sizing and cell counting applications / (opens in a new tab)

  8. Bio-Particle Counting and Sizing Using Micro-Machined Multichannel Coulter Counter with Wavelet Based De-Noising

    … reservoirs. The detection is based on the Coulter counting principle. According to this principle, a particle causes a change in electrolyte-filled micro-channel resistance (or a resistive-pulse) as it passes through the micro-channel. The particle size, surface charge and concentration can …

    ohiolink Repository record for Bio-Particle Counting and Sizing Using Micro-Machined Multichannel Coulter Counter with Wavelet Based De-Noising (opens in a new tab)

  9. Detection of Staphylococcus Aureus Enterotoxin B by Antibody Coated Latex Particles Using Coulter Counter Channel Shifts

    … specific antiserum to enterotoxin B, a model F Coulter Counter, and a 4 K Hewlett- Packard Model 98.30 computer to detect aqueous dilutions of purified enterotoxin B.

    sdstate Repository record for Detection of Staphylococcus Aureus Enterotoxin B by Antibody Coated Latex Particles Using Coulter Counter Channel Shifts (opens in a new tab)

  10. Venezuelan Equine Encephalomyelitis Virus Induced Mammalian and Mosquito Cell Volume Changes as Detected with the Coulter Counter

    … system described in this thesis uses the Boulter Counter, a computer analysis, and a simplified procedure which makes the system suitable and automation. The need also exists for an inexpensive virus detection system. The system proposed in this investigation uses no expensive animal facilities …

    sdstate Repository record for Venezuelan Equine Encephalomyelitis Virus Induced Mammalian and Mosquito Cell Volume Changes as Detected with the Coulter Counter (opens in a new tab)

  11. An evaluation of a Coulter Counter method for the determination of primary productivity, and an assessment of seasonal phytoplankton biomass and species composition at West Blue Lake, Manitoba

    … production by use of an electronic particle counter (Coulter Counter). In order to convert productivity values determined as volume by this method into more meaningful carbon values, it was necessary to establish a relationship between carbon and volume. Although the method was found to be …

    manitoba Repository record for An evaluation of a Coulter Counter method for the determination of primary productivity, and an assessment of seasonal phytoplankton biomass and species composition at West Blue Lake, Manitoba (opens in a new tab)

  12. Multiplexed microfluidic sensor for the cell, cell secretome, and particulate matter detection

    … on the magnetic bead assay and a two stage micro Coulter counter. The device can not only accurately measure the size distribution and concentration of cells, but also detect specific target cells from the average transit time delay of a cell population. Next, to improve the detection resolution …

    ohiolink Repository record for Multiplexed microfluidic sensor for the cell, cell secretome, and particulate matter detection (opens in a new tab)

  13. Are distinct particle spectra an indication of the state of the phytoplankton community in St Helena Bay?

    … coast of South Africa had been analysed with the Coulter Counter and formed the basis of this study. Chlorophyll a content of phytoplankton samples was also measured on monthly cruises and with total particle concentration (determined by the Coulter Counter) showed that overall phytoplankton cells …

    cape-town Repository record for Are distinct particle spectra an indication of the state of the phytoplankton community in St Helena Bay? (opens in a new tab)

  14. Growth in mixed cultures of microorganisms

    … of this interaction was described. A Coulter Counter was used for detecting the number of the microorganisms grown in mixed cultures. Size distribution curves were prepared and used as a means for determining the Coulter Counter settings for counting each organism. Coulter Counter …

    vt Repository record for Growth in mixed cultures of microorganisms (opens in a new tab)

  15. Numerical investigation of hydrodynamic focusing and coulter principle in a microfluidic device

    … and environment detection. Microfluidic Coulter counter is suitable for this task because it can get fast and accurate analysis. However, the fundamental principle and several design strategies details are still needed to be analyzed and modeled in order to improve its performance. This …

    louisville Repository record for Numerical investigation of hydrodynamic focusing and coulter principle in a microfluidic device (opens in a new tab)