Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"Critical Clearing Time"”.

  1. An Investigation Into the Impact of Inverter Based Resources on Critical Clearing Time

    … work studies this impact through the metric of critical clearing time (CCT). Impact of grid topology, generation mix and control modes of IBRs on CCT is studied and results are explained through physical reasoning. Two IEEE test systems are simulated on the real-time digital simulator (RTDS) to …

    clemson Repository record for An Investigation Into the Impact of Inverter Based Resources on Critical Clearing Time (opens in a new tab)

  2. Study and Simulation of Model-Reference Adaptive Control via the Heffron-Philips Model for Enhanced Power System Stability

    … transient stability, which is measured by its critical clearing time. As increased amounts of renewable generation connected to power systems have resulted in reduced critical clearing times of the remaining conventional generators that are needed for grid stability. The use of standard control …

    arkansas Repository record for Study and Simulation of Model-Reference Adaptive Control via the Heffron-Philips Model for Enhanced Power System Stability (opens in a new tab)

  3. A method for determining transient stability in power systems

    … phase symmetrical fault, and to the subsequent clearing of the fault. It is inherent in the method that an estimation of system stability, assuming an instantaneous clearing of the fault, is available. The critical clearing time is therefore determined. The effect of a speed control loop on the …

    must-thes Repository record for A method for determining transient stability in power systems (opens in a new tab)

  4. Étude de la stabilité transitoire à l'aide de l'algorithme SIME

    … linéaire de la marge de stabilité autour du CCT (critical clearing time) et une variation dans le nombre des machines critiques dans la recherche du CCT. En conclusion, en utilisant un programme de stabilité transitoire et à l’aide du critère d’égalité des surfaces, SIME calcule de façon simple la …

    ets-quebec Download PDF for Étude de la stabilité transitoire à l'aide de l'algorithme SIME (opens in a new tab)

  5. Asymptotic stability of large scale dynamical systems using computer generated Lyapunov functions

    … of the overall system, and to estimate the critical clearing time if the power system is faulted during its steady state operation. The results are also applied in stabilizing a long train control system so that the system is globally asymptotically stable.</p>

    iastate Repository record for Asymptotic stability of large scale dynamical systems using computer generated Lyapunov functions (opens in a new tab)

  6. Power System Stability Assessment with Supervised Machine Learning

    … Data-driven Security Assessment for the Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS) project. Data-driven methods offer to improve power flow scheduling through machine learning prediction, enabling better energy resource management and reducing demand on real-time …

    ut-knoxville Repository record for Power System Stability Assessment with Supervised Machine Learning (opens in a new tab)

  7. Design of secure and stable power system integrated with renewable energy sources

    … energy function is proposed to determine the Critical Clearing Time (CCT) of the power system integrated with wind power plant. This technique will enable us to easily define the CCT in comparison with the conventional time-consuming numerical analysis. Modern power system integrated with …

    ttu Repository record for Design of secure and stable power system integrated with renewable energy sources (opens in a new tab)

  8. Power System Frequency and Transient Stability Analysis and Control for High Renewable Power Grids

    … and inter-area oscillations, necessitating real-time inertia estimation software and Wide Area Oscillation Damping Controllers (WADCs). Furthermore, the enormous increase in the amount of large voltage-sensitive-load in modern grids, such as AI data centers, exacerbate these challenges through …

    utk-theses Repository record for Power System Frequency and Transient Stability Analysis and Control for High Renewable Power Grids (opens in a new tab)

  9. Adaptive Online Transient Stability Assessment of Power Systems for Operational Purposes

    … equipment so that they effectively work for critical contingencies. However, there are times an unforeseen contingency may occur which may cause the system to transit and the protective equipment to misoperate and does not isolate the disturbed part of the system. This research introduces a …

    uno Repository record for Adaptive Online Transient Stability Assessment of Power Systems for Operational Purposes (opens in a new tab)

  10. Increasing wind power penetration and voltage stability limits using energy storage systems

    … turbines shows that the ESS increases the farm critical clearing time (CCT) by 1 cycle for worst-case bolted three-phase-to-ground faults. For bolted single-phase-to-ground faults, the CCT is improved by 23.1%-52.2%.

    texas Repository record for Increasing wind power penetration and voltage stability limits using energy storage systems (opens in a new tab)

  11. IMPLEMENTATION OF PROBABILISTIC TECHNIQUES IN TRANSIENT STABILITY STUDIES

    … such as fault types, fault locations, fault clearing schemes, system parameters and initial operating conditions greatly affect the transient performance of a system. A number of these factors are probabilistic in nature. The probabilities of the occurrence of these factors vary from one …

    sask Repository record for IMPLEMENTATION OF PROBABILISTIC TECHNIQUES IN TRANSIENT STABILITY STUDIES (opens in a new tab)

  12. Investigation into the stability of low-inertia micro-grids

    … multi-VSG MG. A systematic calculation of the Critical Clearing Time is also introduced here to provide a quantitative measure of MG stability to complete the study. The second method to study the MG stability is a proposed convex hull-based trajectory reversing method. The proposed method …

    uoit Repository record for Investigation into the stability of low-inertia micro-grids (opens in a new tab)

  13. Transients in Electricity Networks with Distributed Generation

    … in different micro-grid configurations. The critical clearing time (CCT) of the micro-grid under the three-phase fault condition is also discussed. The research results, from both computer simulations and laboratory experiments, show that the micro-grid transient performance is affected by a …

    unsw Repository record for Transients in Electricity Networks with Distributed Generation (opens in a new tab)

  14. Composite power system well-being analysis

    … method in the analytical evaluation of the critical clearing time which forms the basis of most existing stability assessments. The effect of employing high-speed-simultaneous or adaptive reclosing schemes is presented in this thesis. An effective and fast technique to incorporate voltage …

    sask Repository record for Composite power system well-being analysis (opens in a new tab)

  15. Sparse Formulation of Lyapunov Direct Method Applied to Transient Power System Stability

    … and consumes significant computational time. This represents a serious drawback of the RNF, especially in applications to large power networks. Also, all system loads are modeled as constant impedance loads in order to use conventional techniques to reduce the network to the internal …

    mcmaster Repository record for Sparse Formulation of Lyapunov Direct Method Applied to Transient Power System Stability (opens in a new tab)

  16. High Frequency AC Power Systems

    … perturbations caused by short circuits, the Critical Clearing Time (CCT) was found to scale proportionally to the inverse square-root of system frequency. Thus, successful use of HFAC systems requires development of faster-acting circuit protection devices. The upper limit of operating …

    south-carolina Repository record for High Frequency AC Power Systems (opens in a new tab)

  17. Distributed Multi-Agent Approach for Enhancing Stability and Security of Emerging Smart Grids

    … by proper relay coordination to operate with the critical clearing time (CCT) information. A hybrid approach, combination of direct and time-domain simulation methods, is used for CCT calculation. The agents dynamically adapt online measurements and use the CCT information for relay coordination …

    unsw Repository record for Distributed Multi-Agent Approach for Enhancing Stability and Security of Emerging Smart Grids (opens in a new tab)

  18. Machine Learning-Incorporated Transient Stability Prediction and Preventive Dispatch for Power Systems with High Wind Power Penetration

    … issues in case of a contingency using real-time measurements, and the latter enhances the system stability against preconceived contingencies leveraging power dispatch. Over the last decade, large-scale renewable energy generation has been integrated into power systems, with wind power being …

    sask Repository record for Machine Learning-Incorporated Transient Stability Prediction and Preventive Dispatch for Power Systems with High Wind Power Penetration (opens in a new tab)

  19. A fast method for out-of-step protection using state plane trajectories analysis

    … of the generator speed and power angle. The critical clearing angle is computed using the principle that the total energy of the system at the instant the fault is cleared should be equal to the maximum potential energy of the system. The critical clearing time corresponding to this value of …

    sask Repository record for A fast method for out-of-step protection using state plane trajectories analysis (opens in a new tab)