Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"Cryogenic detectors"”.

  1. Analysis of new cryogenic detectors with light nuclei to extend the CRESST dark matter sensitivity

    Seit Jahrzehnten sieht sich die wissenschaftliche Gemeinschaft mit mehreren astronomischen Beobachtungen konfrontiert, die auf die Existenz einer unbekannten, nicht leuchtenden Materie hinweisen, die heute als dunkle Materie bezeichnet wird. Es wurden mehrere Theorien über die Natur dieser neuen …

    lmu-germany Repository record for Analysis of new cryogenic detectors with light nuclei to extend the CRESST dark matter sensitivity (opens in a new tab)

  2. Measuring Johnson resistor noise in non-equilibrium conditions

    … of space caused by these waves. Current detectors are limited by thermal noise which is calculated using the Fluctuation Dissipation Theory (FDT). A number of future detectors are planned to operate at cryogenic temperatures to reduce this thermal noise but it introduces some issues to …

    glasgow Download PDF for Measuring Johnson resistor noise in non-equilibrium conditions (opens in a new tab)

  3. Techniques and challenges in low-mass dark matter searches using CDMS style detectors

    … of galactic dark matter in sensitive detectors using a variety of technologies, including: cryogenic solid state detectors, time projection chambers with liquid noble elements, and bubble chambers with superheated fluids. The cryogenic operating temperatures of solid state detectors …

    queens Repository record for Techniques and challenges in low-mass dark matter searches using CDMS style detectors (opens in a new tab)

  4. Cryogenic phonon-scintillation detectors with NTD germanium readout

    <p>Cryogenic detectors are an advanced technology for both dark matter and neutrinoless double beta decay searches, having the key advantage of a range of possible absorber materials that can be used for the detectors. Neutron transmutation doped germanium sensors are highly sensitive thermometers …

    oxford Repository record for Cryogenic phonon-scintillation detectors with NTD germanium readout (opens in a new tab)

  5. Quantitative Assessment and Validation of Thermal Profiles in the ProtoDUNE-II Horizontal Drift Detector Using Computational Fluid Dynamics

    … design and operational parameters for DUNE’s Far Detectors. Accurate prediction of cryostat thermal behavior is critical to predicting liquid Argon purity distributions and detector performance, motivating the development of a validated computational fluid dynamics (CFD) model. This research …

    sdstate Repository record for Quantitative Assessment and Validation of Thermal Profiles in the ProtoDUNE-II Horizontal Drift Detector Using Computational Fluid Dynamics (opens in a new tab)

  6. Cryogenic Scintillators for Rare-Event Searches

    … require highly-sensitive radio-pure detectors to measure extremely rare interactions amidst a sea of background events coming from natural radioactivity. The DAMA/LIBRA dark matter experiment has a long-standing claim of detecting event excesses inconsistent with known background and …

    queens Repository record for Cryogenic Scintillators for Rare-Event Searches (opens in a new tab)

  7. Development of a low background environment for the cryogenic dark matter search

    … limited by radioactive backgrounds. The Cryogenic Dark Matter Search (CDMS) is a direct detection experiment based on novel particle detectors operated at millikelvin temperatures that provide intrinsic background rejection. This capability, however, is not 100% effective. Therefore a low …

    ubc Repository record for Development of a low background environment for the cryogenic dark matter search (opens in a new tab) Download PDF for Development of a low background environment for the cryogenic dark matter search (opens in a new tab)

  8. Improved Carrier Blocking Properties of Interface in Cryogenic Particle Detectors

    Sensitivity of cryogenic particle detectors suffers from various loss and leakage mechanisms which influence carrier transport in the bulk and interface layers of the detectors. Suppressing- and wherever possible, eliminating- such loss mechanisms is imperative to lowering the noise floor of …

    tamu Repository record for Improved Carrier Blocking Properties of Interface in Cryogenic Particle Detectors (opens in a new tab)

  9. Development and optimization of novel cryogenic calorimeters for COSINUS

    … optimization, and characterization of cryogenic sodium iodide (NaI) calorimeters tailored for the COSINUS experiment, a direct dark matter detection experiment designed to independently verify the DAMA/LIBRA findings of a potential dark matter-induced modulation signal. Central to this …

    lmu-germany Repository record for Development and optimization of novel cryogenic calorimeters for COSINUS (opens in a new tab)

  10. Dark Matter Search with Cryogenic Phonon-Light Detectors

    The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) Dark Matter search is aiming to directly detect Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off nuclei in a target. Due to the low event rate expected for WIMP-nucleus scattering the suppression …

    lmu-germany Repository record for Dark Matter Search with Cryogenic Phonon-Light Detectors (opens in a new tab)

  11. Development of MKID Instrumentation for exoplanet direct imaging

    <p>Microwave Kinetic Inductance Detectors (MKIDs) are a highly sensitive cryogenic photodetector. These devices operate by measuring the increase in the surface impedance of a superconducting film when Cooper Pairs are broken by incident photons. This technique allows MKIDs inherent spectral …

    oxford Repository record for Development of MKID Instrumentation for exoplanet direct imaging (opens in a new tab)

  12. Calibration of Infrared Photons in Cryogenic Germanium Detectors

    … physics to the dark matter puzzle. The Super Cryogenic Dark Matter Search experiment (SuperCDMS) is considered one of the pioneer experiments in the direct search for WIMPs. It is based primarily on deploying germanium and silicon detectors at cryogenic temperatures to search for direct …

    queens Repository record for Calibration of Infrared Photons in Cryogenic Germanium Detectors (opens in a new tab)

  13. Low Threshold Detector Studies for Rare Event Searches

    … allow, it becomes imperative to possess detectors featuring lower thresholds and substantial target masses. Another phenomenon demanding the low threshold detectors is coherent elastic neutrino-nucleus scattering (CEνNS), initially foreseen in 1974 [9] and subsequently observed by the …

    tamu Repository record for Low Threshold Detector Studies for Rare Event Searches (opens in a new tab)

  14. A novel phonon-scintillation cryogenic detector and cabling solution for dark matter direct detection

    … to detect WIMP interactions using an array of cryogenic germanium detectors. In the previous EDELWEISS-II phase, the cables and connectors used have been identified as a major source of neutron background in the experiment, which means that further effort aimed at better WIMP-nucleon …

    oxford Repository record for A novel phonon-scintillation cryogenic detector and cabling solution for dark matter direct detection (opens in a new tab)

  15. Development of Low-Energy Calibration Techniques for SuperCDMS using LEDs Operated at Cryogenic Temperatures

    … with a total payload of ~30 kg of Ge and Si detectors, situated in a well-shielded cryostat with ~15 mK at the coldest thermal stage. The experiment aims to probe DM with masses down to 0.3 GeV (0.5 MeV) through nuclear (electron) scattering. To accomplish this, detectors have to have energy …

    queens Repository record for Development of Low-Energy Calibration Techniques for SuperCDMS using LEDs Operated at Cryogenic Temperatures (opens in a new tab)

  16. Hydroxide catalysis and indium bonding research for the design of ground-based gravitational wave detectors

    … To detect these signals, ground-based GW detectors like aLIGO and the French-Italian detector, Advanced Virgo, need to be sensitive to changes in separation of close to 10^-19m between freely suspended test masses spaced up to 4km apart. This has always been a challenge to achieve, thus 50 …

    glasgow Download PDF for Hydroxide catalysis and indium bonding research for the design of ground-based gravitational wave detectors (opens in a new tab)