Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 22 for “"Cryostats"”.
-
Enhanced Portability and Anti-Frosting Functionality of Cryostats for Synchrotron-Based X-ray Imaging
… frozen. We have developed affordable cryostats and novel protocol to not only improve cryo-imaging at current third-generation synchrotrons, but also enable cryo-imaging at existing synchrotrons that have limited accessibility. This dissertation will provide a detailed description of …
-
Characterization, Optimization, and Operation of TES Bolometers for EBEX
… measurements, I performed in test cryostats and in EBEX itself, are reported here. I measured the bolometer normal resistances, thermal conductances, critical temperatures, optical efficiencies, time constants, and noise equivalent powers. I also report on the detector performance, …
-
Search for Neutrinoless Double Beta Decay Using the Full Majorana Demonstrator Dataset
… of high-purity Ge detectors operated in vacuum cryostats housed in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota. The arrays have operated with up to 48.5~kg of detectors (30.9~kg enriched to $\sim$88\% in $^{76}$Ge). The \textsc{Demonstrator} has …
-
Unshielded applications of high temperature superconducting Quantum interference devices
… is given of the various sensor holders and cryostats that were constructed along with the electrical circuits that were designed to collect and process data. Experimental data confirmed the magnetically shielded specification of the sensors that were supplied. The unshielded performance was …
-
Quantifying the Impact of Various Radioactive Background Sources On Germanium-76 Zero-Neutrino-Double-Beta-Decay Experiments
… are sources of background much more serious than cryostats in Ge-76 experiments. Additionally, experimental applications of the Cascades detector were studied by predicting the sensitivity for a 0vBB-decay experiment using GEANT4 simulations. Tellurium-130, an even-even nucleus that can undergo …
-
New low temperature techniques for electron thermometry and thermal isolation
… thermometer is demonstrated in two different cryostats. Compared to previous implementations of a quantum dot thermometer, the work presented here is unique in that it only requires a single gate connection to calibrate and operate, which simplifies the application of the device substantially. …
-
Bioanalytical applications of fluorescence line-narrowing and non-line-narrowing spectroscopy interfaced with capillary electrophoresis and high-performance liquid chromatography
… a major challenge was the design of compact cryostats that are compatible with the above separation techniques and allow for rapid cooldown (≈1 minute). After cooldown the stationary analyte plugs can be interrogated indefinitely, which leads to significantly lower detection limits. …
-
Characterization of photonic crystal silicon-on-insulator optical circuits fabricated by a CMOS foundry
… circuits when they are placed inside optical cryostats.
-
Microfluidically Cryo-Cooled Planar Coils for Magnetic Resonance Imaging
… reduce the thermal noise, however conventional cryostats are not optimum for the microcoils because they typically use a thick vacuum gap to keep samples to be imaged to near room temperature during cryo-cooling. This vacuum gap is typically larger than the most sensitive region of the …
-
Characterisation and design of power electronic converters for superconducting applications
… As all superconducting systems require cooling cryostats, it would be better from the engineering point of view to have the entire electrical network inside the cryostat. This, in turn, requires power electronics to operate at lower temperatures. Literature has indicated that characteristics of …
-
Optical control of superconducting quantum technology
… load to the cryostat. As the cooling power of cryostats is limited, alternatives need to be explored. In this thesis, we focus on optical control of superconducting quantum technology. The idea is to transfer information between room and cryogenic temperature in optical form, via optical fibers …
-
Near infrared absorption bands of the hydroxyl ion in alkali halide crystals
… from connnercially available components. Three cryostats were used: 1) an innnersion cryostat which operated at 1.4°K with the sample in pumped liquid helium, 2) a conduction cryostat with exchange gas switch coupling to the liquid helium bath for sample temperatures between 4.SoK and 78°K, and …
-
Heat conductivity measurements at low temperatures
… range 0.4 to 4.2°K. covered by two different cryostats - a He<sup>3</sup> and a He<sup>4</sup> cryostat. The specimens studied were gadolinium (2 samples), dysprosium (2 samples), holmium (2 samples), erbium (2 samples), terbium (1 sample) and ytterbium (1 sample).</p> <p>The results obtained …
-
Transport Properties of Lateral Spin Valves
… that the effect was not an artefact, three cryostats, three transport sticks, two sample holders and two more systems (Py/Cu/Py and CoFe/Cu/CoFe) were studied.
-
The Thermal Properties of Composite Materials
… by the conventional steady-state method using cryostats of straight-forward design. Differential gold-iron (0.03 at %) versus chromel thermocouples were used for tenperature measurement from liquid hydrogen temperatures down to 2 K. Above these temperatures differential copper versus constantan …
-
Heat Capacity Measurement Method for Small Samples at Low Temperatures
No abstract prepared.
-
CHARACTERIZATION AND APPLICATION OF SOME SILVER ION CONDUCTING GLASSES
… preparation of glasses and low/high temperature cryostats used and electrical characterization etc. are described in detail in Appendices I-V. Method of calculation of ion concentration, oxygen packing density, interhalogen distance and EMF of Ag/I2 couple have also been presented. In the …
-
A He3-He4 dilution refrigerator system
Not available