Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 149 for “"Current Pulses"”.

  1. Battery Modelling For Large Current Pulses

    Non-linearity due to high current pulses and frequency should be accounted for and included in the electrical equivalent circuit model of a battery cell; apart from its dependence on state of charge (SOC) and temperature. In order to obtain a large current pulse characterisation of a given cell, a …

    chalmers Repository record for Battery Modelling For Large Current Pulses (opens in a new tab)

  2. Mechanical properties of metallic materials subjected to current pulses

    Materials used in high-current applications -- Al6061-T6 and Cu 102 -- are subjected to heat pulses of short duration (in the range of a few hundred microseconds to a few milliseconds); immediately following or along with such heat pulses, the specimens are subjected to large mechanical forces. The …

    texas Repository record for Mechanical properties of metallic materials subjected to current pulses (opens in a new tab) Restricted access

  3. Electrocutaneous stimulation via bipolar current pulses : models and experiments

    … investigated. This was done for multiple bipolar pulses by considering selected cases and for single bipolar pulses with a systematic investigation. The main findings were i) that the threshold charge for a single bipolar pulses changes only slightly for different pulsewidths; ii) that the …

    ubc Repository record for Electrocutaneous stimulation via bipolar current pulses : models and experiments (opens in a new tab) Download PDF for Electrocutaneous stimulation via bipolar current pulses : models and experiments (opens in a new tab)

  4. Electronic circuitry for shaping current pulses for small scale transcranial magnetic stimulation coils

    … electromagnetic induction to induce electric currents in brain tissue via a time-varying magnetic field from a coil, stimulating neuronal activity. While extensively studied in humans, small animal TMS coils are less explored, presenting challenges due to the high currents needed and heating …

    waikato-masters Repository record for Electronic circuitry for shaping current pulses for small scale transcranial magnetic stimulation coils (opens in a new tab) Download file for Electronic circuitry for shaping current pulses for small scale transcranial magnetic stimulation coils (opens in a new tab)

  5. TRANSIENT THERMOELECTRIC SUPERCOOLING: ISOSCELES CURRENT PULSES FROM A RESPONSE SURFACE PERSPECTIVE AND THE PERFORMANCE EFFECTS OF PULSE COOLING A HEAT GENERATING MASS

    … with characteristic parameters was applied. The current pulse height and pulse on-time was identified for maximizing Net Transient Advantage, a newly defined metric. The corresponding pulse height and pulse on-time was utilized for the system model. Along with the traditional steady state …

    mtu Repository record for TRANSIENT THERMOELECTRIC SUPERCOOLING: ISOSCELES CURRENT PULSES FROM A RESPONSE SURFACE PERSPECTIVE AND THE PERFORMANCE EFFECTS OF PULSE COOLING A HEAT GENERATING MASS (opens in a new tab)

  6. Interpretation of UHF signals produced by partial discharges in oil-filled power transformers

    … in terms pC. A test cell is designed, and PD current pulses are measured when the insulating oil at the tip of a sharp, conducting protrusion breaks down. Current pulses are recorded using two different measurement circuits, and different pulse shapes are observed. The experiments are of …

    strathclyde Repository record for Interpretation of UHF signals produced by partial discharges in oil-filled power transformers (opens in a new tab)

  7. Control-Oriented Thermal Model for a Hybrid Vehicle Battery

    … controller to adjust magnitude of applied current. BMS used in the work is equipped with limited number of temperature sensors that can measure surface temperature of few cells in the battery pack. Additional temper- ature information can be used for better thermal control of the cells in …

    vt Repository record for Control-Oriented Thermal Model for a Hybrid Vehicle Battery (opens in a new tab)

  8. A new Auxiliary Converter Topology with SiC Components for Railway Applications

    … on the idea which converts the high frequency current pulses into low frequency AC voltages without rectification stages. This thesis starts with theoretical analysis of the initial ideas with the conclusion of two versions of new topology converter proposal: inductive link auxiliary converter …

    lund Repository record for A new Auxiliary Converter Topology with SiC Components for Railway Applications (opens in a new tab) Download PDF for A new Auxiliary Converter Topology with SiC Components for Railway Applications (opens in a new tab)

  9. A Technique for Reference Spur Eradication in Fractional-N Frequency Synthesis

    … Pump (FWVACP) which is inherently insensitive to current mismatch. Charge pump current pulses are modified such that they have a fixed width and occur on the falling edge of the reference signal. Phase error information is embedded in the amplitude of the current pulses. The periodic nature of …

    carleton Repository record for A Technique for Reference Spur Eradication in Fractional-N Frequency Synthesis (opens in a new tab)

  10. Regeneration of Lithium-Ion Cells

    … investigated based on crystal spatial movement, current pulses and a combination if spatial and current pulses. Electrochemical characterization suggested additional capacity fade after the end of regeneration for all approaches. However, an indication towards regained active anode material was …

    chalmers Repository record for Regeneration of Lithium-Ion Cells (opens in a new tab)

  11. An electromagnetic transducer for the production of shock waves in air

    … electrical circuit has been developed to provide current pulses of the high amplitude necessary for such a device. A prototype transducer also has been constructed and tested. The report is primarily a description of this circuit. Basically, the pulse generator consists of two ignitrons, the first …

    ubc Repository record for An electromagnetic transducer for the production of shock waves in air (opens in a new tab) Download PDF for An electromagnetic transducer for the production of shock waves in air (opens in a new tab)

  12. Data Processing Electronics for an Ultra-Fast Single-Photon Counting Camera

    … MCP-PMT into an electron cloud that generates current pulses across a 50×50 cross-strip anode. The Data Processing FPGA executes a massively parallel center-of-gravity coordinate determination algorithm on the digitized current pulses to determine a 2D position and time of arrival for each …

    wustl Repository record for Data Processing Electronics for an Ultra-Fast Single-Photon Counting Camera (opens in a new tab)

  13. Conduction processes in liquids

    … chamber in which pure argon was liquefied. The current pulses resulting from movement of the liberated electrons in the field applied to the plates were analysed electronically. Firstly, it was desired to determine the time taken by the electrons originating from distinct ionization events to …

    ubc Repository record for Conduction processes in liquids (opens in a new tab) Download PDF for Conduction processes in liquids (opens in a new tab)

  14. Detection of electrical pulses during water tree growth in polyethylene

    … techniques. The principle is to detect image currents in two electrodes, via two very low noise, wide bandwidth detectors, using the normal configuration of electrically stressing a dielectric between two electrodes. The two electrodes monitor a polyethylene sample in which water treeing is …

    ut-knoxville Repository record for Detection of electrical pulses during water tree growth in polyethylene (opens in a new tab)

  15. Output Circuits for Cutaneous Muscle Stimulators

    … Constant Voltage Transformer Isolated, Constant Current Transformer Amplified, Microstim Plus, and the Constant Current stimulator. The impedance of the human skin under constant current pulses was studied in 10 human subjects, in which the maximum impedances were computed. Accuracy of circuit …

    umn Repository record for Output Circuits for Cutaneous Muscle Stimulators (opens in a new tab)

  16. D. C. Motor Currents When Supplied by a Three Phase Thyristor Converter

    … presents the mathematical derivation of the currents flowing in a de motor when supplied by a thyristor power supply. It restricts consideration to the case of discontinuous current flow, i.e. discrete current pulses, with either a three phase half-wave or a three phase full-wave converter. …

    marquette Repository record for D. C. Motor Currents When Supplied by a Three Phase Thyristor Converter (opens in a new tab)

  17. DESIGN OF A HIGH PRECISION SAMPLE-AND-HOLD CIRCUIT FOR A/D CONVERTER

    … amplifier are described. The switch includes a current mirror and switching action is controlled by current pulses. This reduces charge injection due to clock feed through and the charge injection is input signal independent, resulting in a greatly improved sample-and-hold accuracy. The …

    nus Repository record for DESIGN OF A HIGH PRECISION SAMPLE-AND-HOLD CIRCUIT FOR A/D CONVERTER (opens in a new tab) Download file for DESIGN OF A HIGH PRECISION SAMPLE-AND-HOLD CIRCUIT FOR A/D CONVERTER (opens in a new tab)

  18. Semiconductor Diode Laser Dynamics

    … laser diodes pumped with nanosecond time scale current pulses is predicted using both an approximate analytic solution and computer simulations. This predicted behaviour is compared with experimental results. Dynamic experiments with an external cavity for extra optical feedback and a …

    mcmaster Repository record for Semiconductor Diode Laser Dynamics (opens in a new tab)

  19. Superconductivity in thin films

    The critical, currents and magnetic fields required to destroy superconductivity have been measured for thin films of indium and tin in the thickness range of 585 Å to 3600 Å, The measurements were made in the region close to the transition temperature, T[subscript c] . The critical current …

    ubc Repository record for Superconductivity in thin films (opens in a new tab) Download PDF for Superconductivity in thin films (opens in a new tab)

  20. Increasing the CO tolerance of PEM fuel cells via current pulsing and self-oxidation

    … to determine and compare the effect of cell current pulsing and "self-oxidation" in increasing the CO tolerance of a PEM fuel cell. The most effective pulsing parameter values were also determined. Current pulsing involves periodically demanding positive current pulses from the fuel cell to …

    tamu Repository record for Increasing the CO tolerance of PEM fuel cells via current pulsing and self-oxidation (opens in a new tab)

Page 1 of 8