Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 83 for “"Current Transformer"”.
-
The Design and Construction of a Current Transformer
The transformer is a piece of apparatus used to transform alternating current power, from high voltage and low current to low voltage and high current or vice versa. It consists of a magnetic circuit of laminated iron linking two separate and distinct coils of wire. Alternating current is supplied …
-
The design & construction of a constant current transformer
Thesis (B.S.)--Michigan Agricultural College, 1916
-
The Design and Construction of a Current Transformer Testing Set
<p>A current transformer testing set utilizing the null method was constructed by the authors, £. Dempsey Jones and W, David Dishner, for the following reasons; primarily they were interested in electrical metering, having been associated with the meter department of the Tennessee Electric Power …
-
Current-Transformer Based Gate-Drive Power Supply With Reinforced Isolation
… design, a low input-output capacitance (CI/O) transformer design, good voltage regulation, as well as good resilience to faults to enable safe and fast operation. In this thesis, a power supply that supplies multiple gate drivers for 10 kV SiC MOSFETs is presented. A transformer design approach …
-
Direct Current Transformer (DCX): Converter Integration, Modular Operation, and Efficiency Improvement Through Synchronous Rectification
El Transformador de Corriente Continua (DCX) es un convertidor CC-CC aislado de relación fija, opera sin control en lazo cerrado, generalmente basado en topologías resonantes para maximizar la eficiencia. Está compuesto por un Generador de Tensión Conmutada de Alta Frecuencia, un transformador, un …
-
High-frequency Current-transformer Based Auxiliary Power Supply for SiC-based Medium Voltage Converter Systems
… does not satisfy the demands. To improve the current designs, this thesis presents a 1 MHz isolated APS design using gallium nitride (GaN) devices with MV insulation reinforcement. By adopting LCCL-LC resonant topology, the proposed APS is able to supply multiple loads simultaneously and …
-
Design and Experimental Investigation of 500kV Current Transformer Seismic Retrofit Utilizing Structure Rocking and Supplemental Damping with Self-Centering
… of the clients supplied. Many legacy components currently installed in the main grid substations were designed with minimal consideration of lateral loads and are not qualified per IEEE693. One of the more critical high-voltage substation components that are vulnerable to earthquake damage is the …
-
Modelling current transformers for abnormal operating conditions
<p>Theory and application of a current transformer are first presented. Current transformer performance in relation to various fault conditions is systematically analyzed.</p><p>From a current transformer characteristic curve and parameters, "unsaturated" and "saturated" expressions are derived. …
-
Current Relations in Current Transformers
… interest because of the great importance of the current transformer in electrical measurements. By means of the current transformer, tests can be made on alternating current apparatus which is subject to high currents.</p> <p>The thesis involves mostly the making of an apparatus for determining …
-
The impact of current transformers on measurement uncertainty of power quality
The impact of current transformer accuracy on the uncertainty of harmonic measurements was investigated. A literature review revealed the lack of traceability of harmonic measurements conducted using IEC 61869-2 or IEC 60044-1 compliant current transformers. Lack of traceability can be problematic …
-
Redução de erros de exatidão em transformadores de corrente para medição de energia elétrica
… to mitigate errors of accuracy in spe-cific current transformers for electric energy measurement. Two solutions are developed: the first is a real-time control system that inhibits the supply of energy delivered to the CT – current transformer by its magnetic circuit and which withdraws this …
-
A microprocessor based bus relay
… a new technique to overcome the problem of current transformer saturation. The protection scheme uses a combination of the percentage differential current principle and the phase comparison principle. A sampling rate of 1440 Hz is used. Existing algorithms for a saturation detector are …
-
Output Circuits for Cutaneous Muscle Stimulators
… The stimulators were labeled Constant Voltage Transformer Isolated, Constant Current Transformer Amplified, Microstim Plus, and the Constant Current stimulator. The impedance of the human skin under constant current pulses was studied in 10 human subjects, in which the maximum impedances were …
-
Low power wireless technologies for AC current sensing
… with the development of a novel RFID ac current sensing technique for smart power monitoring systems. The research aims to explore designing self-tuning RFID tags and antenna designs and transforming simple tags into passive ac current sensors.The sensing mechanism by which a self-tuning …
-
ELECTRICAL POWER SYSTEM CURRENT AND VOLTAGE INSTRUMENTATION CHANNEL ERROR CORRECTION USING UNCONSTRAINED WEIGHTED LEAST SQUARES DYNAMIC STATE ESTIMATION
… to study the problem of error generation in the Current Transformer (CT) and Voltage Transformer (VT) Instrumentation Channels, respectively, and then to investigate the application of a Dynamic State Estimation (DSE) technique to correct for the error generation in each case. The dissertation …
-
Modeling, Detection, and Localization of High-Impedance Faults In Low-Voltage Distribution Feeders
… to investigate typical patterns in the line's current that allow for the detection of these faults. The occurrence of HIFs is detected with harmonic-current phase analysis and localized with recloser-sectionalizer technology as presented in this work. A sectionalizer algorithm is then presented …
-
A method of measuring negative-phase-sequence currents in a three-phase system
A method of measuring the negative-sequence current in an unbalanced three-phase circuit. A four-winding current transformer, in conjunction with a phase shift network and an alternating current ammeter, was used for obtaining a current proportional to, and in phase with, the negative-sequence …
Page 1 of 5