Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 90 for “"Current harmonics"”.

  1. Control of current harmonics in dual three-phase permanent magnet synchronous machine systems

    … density, and high efficiency. However, the major current harmonics are only limited by low impedance composed of resistance and leakage inductance, which makes DTP PMSMs suffer more from current harmonics. This thesis investigates the new and novel control techniques of DTP PMSMs, with particular …

    whiterose Download PDF for Control of current harmonics in dual three-phase permanent magnet synchronous machine systems (opens in a new tab)

  2. ACTIVE CURRENT INJECTION METHOD FOR LIMITING GROUND FAULT CURRENT HARMONICS IN UNDERGROUND COAL MINES

    Current practice in U.S. underground coal mine high-voltage distribution systems is to attempt to limit ground fault current to 25 Amperes and de-energize the circuit at 10 Amperes. However, the significant amount of system capacitance due to the use of shielded cables can cause ground fault …

    uky-thes Repository record for ACTIVE CURRENT INJECTION METHOD FOR LIMITING GROUND FAULT CURRENT HARMONICS IN UNDERGROUND COAL MINES (opens in a new tab)

  3. Reducing stator current harmonics for a doubly-fed induction generator connected to a distorted grid

    … The DFIG is susceptible to electric grid voltage harmonics, which is a potential obstacle for implementing stable wind-energy systems. Two existing rotor voltage controllers are modeled in this thesis for eventual implementation in a laboratory DFIG wind energy system. The first controller uses …

    nps Repository record for Reducing stator current harmonics for a doubly-fed induction generator connected to a distorted grid (opens in a new tab)

  4. Analysis of the impact of nonlinear loads’ harmonics on synchronous generators lifetime

    Nonlinear loads are the cause of current and voltage harmonics present in the power system. Recent developments in power electronics have contributed to an increase in the number of nonlinear loads connected to the power grid. The current harmonics injected by these nonlinear loads have a negative …

    ttu Repository record for Analysis of the impact of nonlinear loads’ harmonics on synchronous generators lifetime (opens in a new tab)

  5. SHUNT ACTIVE POWER FILTERING FOR SMART APPLIANCES

    … energy efficient loads is the introduction of current harmonics onto the local distribution grid. Furthermore, the proliferation of such devices elevates the harmonic content of the supply voltage and the ensuing potential impact on residential distribution networks. This thesis investigates …

    mcmaster Repository record for SHUNT ACTIVE POWER FILTERING FOR SMART APPLIANCES (opens in a new tab)

  6. Novel Control Strategies for High Speed Permanent Magnet Brushless Motor Drives

    … DC (BLDC) operation. In order to solve the current harmonic issues which are common to BLAC drives, the effect of inverter nonlinearity is firstly investigated. It is shown that the nonlinearity effect will generate the 6n±1th order phase current harmonics. Based on the analysis of current …

    whiterose Download PDF for Novel Control Strategies for High Speed Permanent Magnet Brushless Motor Drives (opens in a new tab)

  7. Advanced Active Output Filter for Low Acoustic Noise Adjustable Speed Drive (ASD) System

    … pulse-width modulation (PWM) generated voltage/current harmonics in the audible noise range. However, the bulky passive filters contribute to additional volume and cannot effectively eliminate harmonics at low switching frequency. In this thesis, an active output filter (AOF) is proposed to …

    tamu Repository record for Advanced Active Output Filter for Low Acoustic Noise Adjustable Speed Drive (ASD) System (opens in a new tab)

  8. Analysis of the effects nonlinear loads have on the lifetime of generator sets

    … nonlinear loads also introduce voltage and current harmonics into the power system which in turn has negative effects to the generator, potentially reducing the lifetime of the generator set. The harmonics introduced into the system causes an increase in power losses on the stator windings …

    ttu Repository record for Analysis of the effects nonlinear loads have on the lifetime of generator sets (opens in a new tab)

  9. Disaggregation of residential electric loads using smart metered data

    … highlight the importance of reactive power and current harmonics in determining power consumed and identifying modern electrical devices, and raise concerns related to the ability of typical 15 minute interval utility smart meters to disaggregate loads.

    texas Repository record for Disaggregation of residential electric loads using smart metered data (opens in a new tab)

  10. Analysis and design of high frequency link power conversion systems for fuel cell power conditioning

    … converter to reduce the low frequency input current harmonics drawn from the fuel cell is proposed, and a new PWM technique for the cycloconverter at the secondary to reject the low order harmonics in the output voltages is presented. The performance of the proposed scheme is verified by the …

    tamu Repository record for Analysis and design of high frequency link power conversion systems for fuel cell power conditioning (opens in a new tab)

  11. Investigation of performance improvement of doubly salient synchronous reluctance machine with current harmonic injection

    This thesis investigates some novel current harmonic injection methods to improve the electromagnetic performance of doubly salient synchronous reluctance machines (DS-SRMs). These machines will have different winding configurations, slot/pole number combinations and phase numbers. The theoretical …

    whiterose Download PDF for Investigation of performance improvement of doubly salient synchronous reluctance machine with current harmonic injection (opens in a new tab)

  12. Rating optimization of three phase series hybrid power filter for power quality compensation and renewable energy integration

    … swells, and unbalances. They can also compensate current problems related to linear and non-linear loads, such as load reactive power, current harmonics. In this thesis study, a 3-phase hybrid series power filter for power quality compensation is used for current harmonic, reactive power …

    ets-quebec Download PDF for Rating optimization of three phase series hybrid power filter for power quality compensation and renewable energy integration (opens in a new tab)

  13. Effects of Input Power Factor Correction on Variable Speed Drive Systems

    … harmonic content, magnitude of the system input current and input power factor is particularly addressed in this dissertation along with the development of analytical methods applicable to the steady-state analysis of input power factor corrected VSD systems. Three different types of motors - the …

    vt Repository record for Effects of Input Power Factor Correction on Variable Speed Drive Systems (opens in a new tab)

  14. Analysis, design and implementation of high performance control schemes for three phase PWM AC-DC voltage source converter

    … explanations of the appearance of the even-order harmonics at the dc output voltage and the low frequency odd-order harmonics in the input ac currents are provided under the unbalanced and distorted supply voltage conditions. In order to eliminate the even-order harmonics at the dc link voltage …

    nus Repository record for Analysis, design and implementation of high performance control schemes for three phase PWM AC-DC voltage source converter (opens in a new tab) Download file for Analysis, design and implementation of high performance control schemes for three phase PWM AC-DC voltage source converter (opens in a new tab)

  15. Developing three robust control strategies for Dynamic Voltage Restorer (DVR) for supporting renewable energy resources integration

    … issues such as voltage sag, swell, imbalances, harmonics from the grid, and harmonics caused by non-linear loads. The presence of non-linear loads such as rectifiers, variable-speed drives, electronic devices such as computers servers, and telecoms systems that use a switched-mode power supply …

    ttu Repository record for Developing three robust control strategies for Dynamic Voltage Restorer (DVR) for supporting renewable energy resources integration (opens in a new tab)

  16. CONTROL OF PERMANENT MAGNET SYNCHRONOUS MACHINES WITH SMALL DC-LINK CAPACITOR

    … the dc-link voltage fluctuation can induce the harmonics in the estimated rotor position error, and deteriorate the system stability. A back-EMF harmonic suppression method is proposed to eliminate these rotor position error harmonics and enhance the performance of the EEMF-based sensorless …

    whiterose Download PDF for CONTROL OF PERMANENT MAGNET SYNCHRONOUS MACHINES WITH SMALL DC-LINK CAPACITOR (opens in a new tab)

  17. Design, construction and testing of a reduced-scale cascaded multi-level converter

    … propulsion drive system. The reduction of current waveform harmonics is critical in combatant propulsion systems such as the IPS. One method of reducing the current harmonics is to utilize a multilevel converter topology. The multi-level converter, as compared to a standard converter, …

    nps Repository record for Design, construction and testing of a reduced-scale cascaded multi-level converter (opens in a new tab)

  18. ANALYSIS AND CONTROL OF CIRCULATING CURRENT IN MODULAR MULTILEVEL CONVERTER

    … voltage and high power applications. Circulating current harmonics and the substantial size of its submodule capacitors are the critical issues in MMC. In this thesis, a new control architecture comprising of spatial comb filter (SCF) and spatial repetitive controller (SRC) is proposed to …

    nus Repository record for ANALYSIS AND CONTROL OF CIRCULATING CURRENT IN MODULAR MULTILEVEL CONVERTER (opens in a new tab) Download file for ANALYSIS AND CONTROL OF CIRCULATING CURRENT IN MODULAR MULTILEVEL CONVERTER (opens in a new tab)

  19. Modelling and real-time simulation of a modular bidirectional solid-state transformer for ultra-fast charging of electric vehicles

    … balance and unity power factor, and to mitigate current harmonics and voltage ripples in compliance with IEEE standards, validated by Model-in-the-Loop real-time simulation.

    uoit Repository record for Modelling and real-time simulation of a modular bidirectional solid-state transformer for ultra-fast charging of electric vehicles (opens in a new tab)

  20. DSP-based control of static power quality compensators in industrial power systems

    … regarding power quality, in terms of current harmonics, as reflected in standards such as IEEE-519, and in terms of voltage faults. By exploiting recent advances made in power electronics and digital control circuits, this thesis develops new power conditioning solutions based on the …

    concordia Download PDF for DSP-based control of static power quality compensators in industrial power systems (opens in a new tab)

Page 1 of 5