Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 13 of 13 for “"Current monitor"”

  1. Optical fibre devices: vibrometer, current monitor & amplifier

    … for application as Faraday-effect fibre current monitor. Since, in contrast with conventional fibres, they can be wound in small multi-turn coils whilst retaining their sensitivity. The fibre and its exploitation in three optical schemes is modelled using Jones calculus and also …

    soton Repository record for Optical fibre devices: vibrometer, current monitor & amplifier (opens in a new tab)

  2. Built-in-self-test of RF front-end circuitry

    … has not yet been reported in literature. In the current work, an approach to RF self-test that has hitherto been unexplored both in literature and in the commercial arena is proposed. A sensitive current monitor has been used to extract variations in the supply current drawn by the …

    rit Repository record for Built-in-self-test of RF front-end circuitry (opens in a new tab)

  3. ASIC design to monitor current for low frequency applications

    … in the field of medical diagnostics, pollution monitoring, agriculture, micro-electromechanical systems, computer chips, genetic engineering, point of care systems and many more. These sensors can be used to measure a wide range of bio-chemical parameters such as concentration of molecules, …

    ohiolink Repository record for ASIC design to monitor current for low frequency applications (opens in a new tab)

  4. Microcontroller-based control of a planar haptic device for rehabilitation of the human arm

    … specific robotic rehabilitation platform is currently one of the research and development areas with the objective to assist the conventional motor therapy. The existing solutions, whose diffusion is limited, are either sophisticated or costly. This work is related to a project that is …

    nanyang Repository record for Microcontroller-based control of a planar haptic device for rehabilitation of the human arm (opens in a new tab)

  5. PRECISION CONTROL OF INTENSE ELECTRON BEAMS IN A LOW-ENERGY RING

    … in which there are fewer beam position monitors than beam position correctors and a complex coupling between the horizontal and vertical kicker magnets. In this work, a novel beam control algorithm was developed based on the closed-orbit response matrix, and this algorithm was applied to …

    maryland Repository record for PRECISION CONTROL OF INTENSE ELECTRON BEAMS IN A LOW-ENERGY RING (opens in a new tab)

  6. Automated multi-parameter monitoring of neo-nates

    Advancements in monitoring technology have led to an increasing amount of physiological data; such as heart rate and oxygen saturation, being accumulated in hospitals. A high rate of false alarms in the neonatal intensive care environment due to inadequate analysis of data highlights the need for …

    ucl Repository record for Automated multi-parameter monitoring of neo-nates (opens in a new tab)

  7. Synthesis and evaluation of an autonomous neutron monitor system for use in a very low temperature environment

    … around since 1932 and as such, so has neutron monitors used to observe these high energy particles. One of the determining factors influencing the measurement of particles is that of physical location. The higher altitude and latitude monitors were found to observe more particles necessitating …

    nwu-za Repository record for Synthesis and evaluation of an autonomous neutron monitor system for use in a very low temperature environment (opens in a new tab)

  8. Malý programovatelný napájecí zdroj

    Práce se zabývá návrhem a konstrukcí kompaktního spínaného napájecího zdroje malého výkonu, napájeného z USB rozhraní. Zdroj umožňuje nastavit výstupní napětí v rozsahu 0 V až 16 V a má nastavitelné proudové omezení. Návrh je proveden tak, aby byla zajištěna galvanická izolace od počítače. Řízení …

    brno-tech Repository record for Malý programovatelný napájecí zdroj (opens in a new tab)

  9. Embedded test circuits and methodologies for mixed-signal ICs

    … circuits. The first one is a built-in current monitor (BICM) suitable for power supply current (IDD) testing. The B I CM includes a built-in current sensor (BICS) which provides high measurement sensitivity without introducing a large impedance in the IDD path. Although the BICS …

    ubc Repository record for Embedded test circuits and methodologies for mixed-signal ICs (opens in a new tab)

  10. A Cost-Effective, Noninvasive Dual Impedance-Based Wearable for Continuous Monitoring of Cardiovascular Health: Development of the Analog Front-End

    … low-cost, wearable devices that are capable of monitoring cardiovascular health for early detection and prevention. One approach for predicting the onset of CVDs includes the tracking of blood pressure (BP) and heart rate. This work focuses on the development of the analog front-end for a …

    tamu Repository record for A Cost-Effective, Noninvasive Dual Impedance-Based Wearable for Continuous Monitoring of Cardiovascular Health: Development of the Analog Front-End (opens in a new tab)

  11. Techniques for designing robust and reliable analog circuits

    … testing, on-chip transistor degradation monitoring, and lowering AMS test costs in general or through the use of already available on-chip resources is the way forward to deal with these robustness and reliability issues. In this this dissertation all these techniques have been touched …

    iastate Repository record for Techniques for designing robust and reliable analog circuits (opens in a new tab)

  12. Měření a vyhodnocování spotřeby zařízení IoT

    Táto práca sa zaoberá vyhodnocovaniu napájania a spotreby IoT zariadení. Ďalej sa zaoberá rozborom profilu odberu prúdu týchto zariadení ako aj rozborom vhodného napájacieho zdroja. V práci sú analyzované jednotlivé typy primárnych batérii a ich vhodnosť použitia v tejto oblasti. Ďalej sa práca …

    brno-tech Repository record for Měření a vyhodnocování spotřeby zařízení IoT (opens in a new tab)