Showing 1 to 20 of 111 for “"Cuvette"”.

  1. Spatial characteristics of a furnace atomization plasma excitation spectometry source

    … frequency (r.f.) plasma is created inside the cuvette of a graphite furnace atomizer by applying r.f. power to an electrode placed inside, and coaxial with, the atomization chamber of the cuvette. The plasma provides the energy to excite analyte atoms which then emit the light measured as the …

    ubc Repository record for Spatial characteristics of a furnace atomization plasma excitation spectometry source (opens in a new tab) Download PDF for Spatial characteristics of a furnace atomization plasma excitation spectometry source (opens in a new tab)

  2. Nanosistemas de penicilina G benzatina para tratamento profilático da febre reumática: estudo analítico

    … curves for drug analysis: the stationary cuvette one. It was compared to the currently used methodology, and possible sources of variation between them were evaluated. The results demonstrated that the proposed technique presented similar reproducibility compared to the traditional …

    brazil-ufrn Repository record for Nanosistemas de penicilina G benzatina para tratamento profilático da febre reumática: estudo analítico (opens in a new tab)

  3. Improved Near Infrared Analysis Method for Bovine Milk

    … in milk through measurement and certification of cuvette path length was developed using a confocal displacement sensor. This new method nondestructive method to measure cuvette path length eliminates the need for use of potassium chromate. Partial least square predictive models for homogenized …

    cornell Repository record for Improved Near Infrared Analysis Method for Bovine Milk (opens in a new tab)

  4. Microbubble Generation By Piezoelectric Transducers For Biomedical Studies

    … transducer to produce microbubbles in a cuvette loaded with cell-culture medium. Several transducer configurations were designed and tested. The first design has a transducer that faces upward in a water chamber, so that the pressure waves can reach a coverslip placed above the …

    odu Repository record for Microbubble Generation By Piezoelectric Transducers For Biomedical Studies (opens in a new tab)

  5. Bacterial Transformation Using Microfluidic Continuous Electroporation in Paper (µCEP)

    … bacterial cells by disrupting the cell membrane. Cuvette-based EP systems are commercially available but are limited to small sample volumes and have shown inconsistencies in EP efficiency. Furthermore, high electric fields are required in these systems; the high voltage applied causes …

    tamu Repository record for Bacterial Transformation Using Microfluidic Continuous Electroporation in Paper (µCEP) (opens in a new tab)

  6. Microbial Extracellular Enzymes in Marine Sediments: Methods Development and Potential Activities in the Baltic Sea Deep Biosphere

    … reader and a Promega Glomax multi JR single cuvette fluorimeter and results were compared to determine which yielded the most high resolution and dependable results. The Promega single-cuvette fluorimeter proved to be the more precise method because instrumental drift over time, intrawell …

    ut-knoxville Repository record for Microbial Extracellular Enzymes in Marine Sediments: Methods Development and Potential Activities in the Baltic Sea Deep Biosphere (opens in a new tab)

  7. Subnanosecond Exposure Systems for Biological Studies

    … exposure system designed for cell exposure is a cuvette consisting of two parallel aluminum gaps. This cuvette is placed in a coaxial transmission line which is terminated by a conical resistor array. The capacitance of the cuvette was designed to be on the order of 1-2 pf, so the risetime of the …

    odu Repository record for Subnanosecond Exposure Systems for Biological Studies (opens in a new tab)

  8. Chemistry of Carbon Sulfides

    … which was continuously pumped through the sample cuvette to avoid heating. The susceptibilities of the molecules in solution was determined by subtracting the susceptibility of the solvent from that of the solution. The highest susceptibilities were found to be for C6S8O 2 and (Me4N)4[Zn10(SPh)16].

    uiuc Repository record for Chemistry of Carbon Sulfides (opens in a new tab)

  9. Antibody-catalyzed formation of a 14-membered ring lactone

    … a multiwell method and the spectrophotometric cuvette method. Analysis of the reaction of F123 with 57 via the multiwell method yielded a Km of 250 ± 10 uM, Vmax of 0.62 ± 0.01 ixmol/min mg and a kcat of 1.1 min"1. The spectrophotometric cuvette method yielded a rCr, of 330 ± 50 uM, V m a x of …

    ubc Repository record for Antibody-catalyzed formation of a 14-membered ring lactone (opens in a new tab) Download PDF for Antibody-catalyzed formation of a 14-membered ring lactone (opens in a new tab)

  10. 3D-PRINTED MICROFLUIDIC CAPILLARIC CIRCUITS FOR THE AUTOMATION OF RADIOPHARMACEUTICAL SYNTHESIS

    … across four test sessions alongside conventional cuvette controls. In final testing, the chip platform achieved radiolabeling efficiencies exceeding 94% within 5 minutes, compared to 20 minutes required by the cuvette method to reach comparable efficiency, a fourfold reduction in synthesis time. …

    maryland Repository record for 3D-PRINTED MICROFLUIDIC CAPILLARIC CIRCUITS FOR THE AUTOMATION OF RADIOPHARMACEUTICAL SYNTHESIS (opens in a new tab)

  11. Fluorescence correlation spectroscopy: ultrasensitive detection in clear and turbid media

    … a mechanical instrument that holds a cylindrical cuvette (1 cm in diameter) with two motors that provide a rotational and a slower vertical inversion motions. The illumination focus is centered about 200 μm from the wall of the cuvette inside the sample. The total volume that is explored is large …

    uiuc Repository record for Fluorescence correlation spectroscopy: ultrasensitive detection in clear and turbid media (opens in a new tab)

  12. The development of spectrofluorometric instruments for the detection of petrochemical contamination in water

    … The online measurement system is the first cuvette-based instrument that produces full fluorescence spectra in real time for the analysis of BTEX, monoaromatic hydrocarbons, PAHs, crude oil and gas condensates in water. <br/><br/><i>This thesis is permanently embargoed and is unavailable for …

    qu-belfast Repository record for The development of spectrofluorometric instruments for the detection of petrochemical contamination in water (opens in a new tab)

  13. The Luminometer: A Sensitive Instrument for Measuring Low Amounts of Oxygen, and Some Applications to Problems Involving the Measurement of Photosynthesis

    … carrier gas flows at a controlled rate through a cuvette, then over a solution of luminol and potassium t-butoxide in dimethylsulfoxide (DMSO). The light generated by the chemiluminescent reaction of luminol with oxygen is measured with a photomultiplier. A constant rate of oxygen production by …

    rockefeller Repository record for The Luminometer: A Sensitive Instrument for Measuring Low Amounts of Oxygen, and Some Applications to Problems Involving the Measurement of Photosynthesis (opens in a new tab)

  14. Dual Interferometer System for Measuring Index of Refraction

    … lens material sample is placed in a measurement cuvette, where it remains hydrated. By measuring the locations of the multiple optical interfaces, the physical thickness t of the material is measured. A new algorithm has been developed for processing the low coherence signals obtained from the …

    arizona-thes Repository record for Dual Interferometer System for Measuring Index of Refraction (opens in a new tab)

  15. Quantifying and Understanding the Tropical Peatlands of the Central Congo Basin

    … to establish whether this region, known as the Cuvette Centrale, harbours significant peatlands, to characterise them, compute the first estimate of peatland extent and C stocks based on ground data, to determine the factors which led to peat initiation and their maintenance today. Fieldwork …

    whiterose Download PDF for Quantifying and Understanding the Tropical Peatlands of the Central Congo Basin (opens in a new tab)

  16. Improved recipes for leuco-crystal violet micelle gel dosimeters

    … water and 4 wt% gelatin. Results from replicate cuvette experiments showed that the proposed gel recipe is dose-rate independent and has an average DS equal to 0.0141 Gy-1 cm-1. No statistically significant energy-dependence was observed in cuvette experiments involving 12 MeV electrons and 6 MV …

    queens Repository record for Improved recipes for leuco-crystal violet micelle gel dosimeters (opens in a new tab)

  17. Early Detection System for Water Quality Monitoring of Cyanobacteria and Hexavalent Chromium using UV-Vis Derivative Spectrophotometry and Improvement of Detection Limit by Changing Pathlength

    … of derivative spectrophotometry with changing cuvette pathlength (10-, 50-, and 100-mm) to be used as an early warning system for sensitive determination of the aforementioned parameters. Initially, Microcystis aeruginosa (cyanobacteria) and Chlorella vulgaris (green algae) were inoculated in …

    carleton Repository record for Early Detection System for Water Quality Monitoring of Cyanobacteria and Hexavalent Chromium using UV-Vis Derivative Spectrophotometry and Improvement of Detection Limit by Changing Pathlength (opens in a new tab)

  18. Laser-induced heating, phase-shift, and damage : measurements and simulations

    … rate thermal camera system in an optical cuvette determined rates of heating and cooling in water exposed to 1200, 1310 and 1318-nm wavelengths. Thermal modeling software (BTEC) developed at AFRL was used to simulate the beam parameters that were used experimentally. The simulation was …

    texas Repository record for Laser-induced heating, phase-shift, and damage : measurements and simulations (opens in a new tab)

  19. Two-Photon Upconversion Process and its Application to Infrared Vision

    … IR-reflecting mirrors on four sides of the cuvette containing the microparticles. Additionally, we developed and fabricated microparticle-coated lenses for use as eyeglasses, allowing for the visualization of intense infrared light images converted to visible light. The results of this study …

    tamu Repository record for Two-Photon Upconversion Process and its Application to Infrared Vision (opens in a new tab)

  20. Application of a ratiometric laser induced fluorescence (LIF) thermometry for micro-scale temperature measurement for natural convection flows

    … verses temperature obtained using an isothermal cuvette, which was controlled by two thermo-bathes. 488nm Ar-ion laser used for incident light and two filter sets used for separating each fluorescence emission. Thermally stratified filed of 10mm channel with micro-scale resolution measured within …

    tamu Repository record for Application of a ratiometric laser induced fluorescence (LIF) thermometry for micro-scale temperature measurement for natural convection flows (opens in a new tab)