Showing 1 to 20 of 184 for “"Cytometer"”.
-
An impedance based single cell deformability cytometer
… events. High-throughput in-flow deformability cytometers have been recently developed, exploiting hydrodynamic forces to deform the cells. However, the use of optical systems to evaluate cell shape limits the potential of these solutions for point-of- care applications. This work describes a …
-
Integrated optical microflow cytometer for bead-based immunoassays
… cell biology. However, traditional flow cytometers are expensive, bulky and complex to operate. Miniaturised flow cytometers or microflow cytometers offer advantages over traditional devices, being compact, cheap and mass producible and would offer the user ease of operation and low …
-
Multiwavelength parallel single cell optical transit differential dielectrophoresis cytometer
… optical transit differential dielectrophoresis cytometer strategy, enable rapid deployment of automated experiments, and provide a reliable platform for future data collection. These objectives were achieved through the development of two generations of hardware platforms. The first generation …
-
Dual-modality optical-dielectric cytometer for microplastic and single-cell analysis
… presents a non-invasive and label-free video cytometer capable of simultaneously measuring morphological and dielectric properties of particles in flow. The dual-modality optical-dielectric cytometer utilizes a high-speed camera focused in a microfluidic channel with integrated coplanar …
-
A paraboloidal flow cytometer for improved fluorescence analysis of single cells
<p>A new flow cytometer featuring a paraboloidal flow chamber for optical collection has been designed to improve fluorescence analysis of single cells. The improvement is achieved by increasing the fluorescence collection efficiency, permitting measurement of weakly fluorescent particles, and by …
-
A miniaturized microfluidic cytometer platform for point-of-care blood testing applications
In recent years, microfluidic lab-on-a-chip devices have made tremendous progress. Many new features, new processes and fabrication methodologies have been proposed and realized in the last two decades. In the field of clinical diagnostics, however, there still lack devices and products that truly …
-
Development of a Diffraction Imaging Flow Cytometer for Study of Biological Cells
… designed and built a diffraction imaging flow cytometer with the ability to efficiently acquire high-contrast diffraction images from individual flowing cells. A series of experimental and modeling studies have been carried out to build this instrument including fabrication of square …
-
Evaluation of Stallion Sperm Membrane Integrity Using Varied Flow Cytometer-Based Methodologies
Artificial insemination using cooled, transported semen has become a popular practice in the equine industry. However, equine sperm are assumed to show a decline in their fertilizing ability after 24 to 48 hours of cooled storage. Two measures that are commonly used to estimate the fertility of an …
-
Microwave Flow Cytometer for Single Cell Detection, Differentiation, and Drug Effect Study
New methods to rapidly detect and identify pathogens in patients’ blood are needed for timely disease treatment. In this work, a tunable microwave interferometer was used to measure single Candida cells of C. albicans, C. tropicalis, C. parapsilosis, and C. krusei at multiple frequencies between …
-
Flow cytometer optimisation and standardisation for the study of extracellular vesicles as translational biomarkers
… this thesis, I have developed methods for flow cytometer (FCM) resolution quantification, improvement, and standardisation. This involved building, testing and validating FCM optical models for EV analysis standardisation, and optimising FCM settings and protocols to increase resolution and …
-
Design and Operation of a Microwave Flow Cytometer for Single Cell Detection and Identification
… In this dissertation a microwave flow cytometer is designed and used to measure single biological cells and micro particles. A radio frequency (RF)/microwave interferometer serves as the measurement system for its high sensitivity and tunability and we show that a two-stage …
-
Fluorescence activated sorting of antibody-labeled islets using an EPICS Elite ESP flow cytometer
A Beckman Coulter EPICS Elite ESP Flow Cytometer with a 400 [Mu]m tip was used to attempt to separate pancreatic tissue from acinar cells following digestion of the pancreas with collagenase. The islets were fluorescently labeled by using A2B5 as a primary antibody, and either a FITC or …
-
Investigation of microscale particles using a microfluidic flow cytometer equipped with a sensitive photodetector
<p>We have developed a sensitive optofluidic cytometer to investigate microscale particles. The flow cytometer is comprised of a microchannel that has a set of chevron-shaped grooves. Conducted by the chevrons, two sheath streams focus the core stream in the center of the microchannel …
-
A droplet-based microfluidic impedance flow cytometer for detection and quantification of microplastics in water
The purpose of this thesis is to design and test a new microfluidic device based on impedance cytometry principles for detecting and quantifying microplastics in droplets. To measure the size and concentration of microplastics, we created a flow-focusing droplet generator with coplanar electrodes. …
-
Development of a Microchip-Based Flow Cytometer with Integrated Optics – Device Design, Fabrication, and Testing
<p>Lab-on-a-chip technologies have created a burgeoning number of new and novel devices designed to automate biological processes on-chip in an efficient and inexpensive format for far reaching point-of-care (POC) medicine and diagnostic treatments and for remote and on-line monitoring functions. …
-
Design and implementation of integrated GHz frequency capacitance cytometer with aF sensitivity for single cell characterization
… 15 µm PSS. The third design is an integrated DEP cytometer sensor. It is composed of an optimized capacitance sensor implemented using 0.35 μm CMOS technology, on which a machined PMMA microfluidic is clamped to provide a path for cells to flow. The capacitance sensor operates at 500 MHz/1.4 GHz, …
-
An Artificial neural network-based signal classifier for automated identification of detection signals from a dielectrophoretic cytometer
… of cells flowing through a dielectrophoretic cytometer. In past work, the DEP cytometer signals were manually sorted by going through all recorded signals, which is impractical when analyzing 1000’s of cells per day. In the semi-automated method of collection, signals are automatically …
-
Design, fabrication and characterisation of a low-cost, acoustically focussed imaging flow cytometer for automated analysis of phytoplankton
… acoustically focussed Imaging Flow Cytometer for low-cost imaging of phytoplankton in natural water samples, making use of off-the-shelf optical and mechanical components. Acoustic focussing is used as it is a contact-free, gentle and reliable particle positioning method which allows …
-
Monitoring Dielectric Properties of Single MRC5 Cells and Oligomycin Treated Chinese Hamster Ovary Cells Using a Dielectrophoretic Cytometer
We have employed a differential detector combined with dielectrophoretic (DEP) translation in a microfluidic channel to monitor dielectric response of single cells and particularly to track phenomenon related to apoptosis. Two different cell lines were studied; Chinese hamster ovary cells (CHO) and …
-
Development of a microfluidic flow cytometer for plant protoplast analysis and manipulation by means of laser radiation pressure
… a PDMS based, all-fiber microfluidic cell cytometer in which we tested with both beads and Arabidopsis mesophyll protoplasts and were successful in distinguishing both RFP and GFP labeled plant cells. We employ several techniques to improve data quality: By adding hydrodynamic focusing we …