Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 47 for “"DAQ system"”.

  1. DEVELOPMENT OF MULTISCALE RADIOBIOLOGY SIMULATION AND DAQ SYSTEM FOR RADIOBIOLOGY BEAMLINE

    … The fi rst approach is the development of the DAQ system of the radiobiology beamline which will subsequently be used to perform deterministic targeted irradiation of the cells for fundamental study. The second involves the development of a mechanistic radiobiology simulation software to …

    nus Repository record for DEVELOPMENT OF MULTISCALE RADIOBIOLOGY SIMULATION AND DAQ SYSTEM FOR RADIOBIOLOGY BEAMLINE (opens in a new tab) Download file for DEVELOPMENT OF MULTISCALE RADIOBIOLOGY SIMULATION AND DAQ SYSTEM FOR RADIOBIOLOGY BEAMLINE (opens in a new tab)

  2. Design and implementation of a space qualified DAQ system for the HEPD-02 silicon tracker

    … lithosphere-atmosphere-ionosphere-magnetosphere system. The CSES program with its satellites performing a simultaneous and accurate measurements of particle fluxes and the E and B fields, it is supposed to study and clarify this possible correlation. It is also important to mention that CSES …

    trento Repository record for Design and implementation of a space qualified DAQ system for the HEPD-02 silicon tracker (opens in a new tab)

  3. Development of a Field Monitoring System for the Northside Drive Bridge

    This project aims to create a system for real-time structural monitoring of bridges, ultimately offering a reliable method to accurately estimate a bridge’s remaining fatigue life. Standard procedures exist to calculate the remaining fatigue life of steel bridges. However, such procedures rely on …

    gatech Repository record for Development of a Field Monitoring System for the Northside Drive Bridge (opens in a new tab)

  4. Thin film, wireless, flexible sensing system for real-time cell-culture monitoring

    … design a flexible small form factor monitoring system for cell bag bioreactors. Since polymer encapsulated flexible electronics and thin film sensors achieve lower stiffness and higher flexibility, they can form a monitoring system that has the capacity to undergo deformation with the soft …

    gatech Repository record for Thin film, wireless, flexible sensing system for real-time cell-culture monitoring (opens in a new tab)

  5. Προσομοίωση ανάλυση και επανασχεδιασμός του συστήματος λήψης δεδομένων του πειράματος CMS

    The Data Acquisition (DAQ) system for the CMS experiment at the LHC is responsible for forming full events, corresponding to the detector information originated from a single proton-proton beam crossing, by collecting data from around 500 data sources at an aggregate throughput of 100GB/s. The …

    greece Repository record for Προσομοίωση ανάλυση και επανασχεδιασμός του συστήματος λήψης δεδομένων του πειράματος CMS (opens in a new tab)

  6. Advanced control techniques and sensors for gas engines with NSCR

    … Non Selective Catalyst Reduction (NSCR) catalyst system requires complex fuel control strategies. The allowable equivalence ratio operating range is very narrow where NSCR systems achieve simultaneous reduction of Carbon Monoxide (CO), Nitrogen Oxides (NOx), Total Hydrocarbons (THC), Volatile …

    colostate Repository record for Advanced control techniques and sensors for gas engines with NSCR (opens in a new tab)

  7. Rocket Motor Diagnostics using Tunable Diode Laser Spectroscopy for Chemically Non-Reacting Air/Water Vapor Mixture in Internal Flow

    … Diode Laser Absorption Spectrometer (TDLAS) system which was designed to observe water vapor. A super-heated water vapor injector was designed to obtain the desired water vapor concentrations. Flow characteristics were simultaneously recorded using the existing TDLAS system and the DAQ system …

    uno Repository record for Rocket Motor Diagnostics using Tunable Diode Laser Spectroscopy for Chemically Non-Reacting Air/Water Vapor Mixture in Internal Flow (opens in a new tab)

  8. Developing the Detector Array for Energy Measurement of Neutrons (DAEMON)

    … for the significant transition to an ASIC-based DAQ system and prototype testing with monoenergetic neutron beam at the University of Kentucky Accelerator Laboratory.

    guelph Repository record for Developing the Detector Array for Energy Measurement of Neutrons (DAEMON) (opens in a new tab)

  9. Development of Electrical Impedance Tomography Data Acquisition System and Deep Learning-Based Reconstruction Algorithms for Spatial Damage Detection

    … researchers have attempted to make portable EIT systems, but they all rely on external computation for image reconstruction/data analysis. This study outlines the development of a low-cost, portable, and wireless EIT data acquisition (DAQ) system that is capable of independently performing image …

    calpoly Repository record for Development of Electrical Impedance Tomography Data Acquisition System and Deep Learning-Based Reconstruction Algorithms for Spatial Damage Detection (opens in a new tab)

  10. Comissioning and Calibration of a Small-Scale Modular Liquid Argon Detector, Argon-1, for Novel Studies in Background Rejection Techniques Towards Next-Generation Dark Matter Detectors

    … the design and commissioning of the DAQ system, a slow controller program, and a GEANT4 based simulation. The detector light yield is 4.7 photo-electrons/keV, with an energy resolution of ∼ 5%. We outline a measurement plan for a novel background rejection technique using a layered …

    carleton Repository record for Comissioning and Calibration of a Small-Scale Modular Liquid Argon Detector, Argon-1, for Novel Studies in Background Rejection Techniques Towards Next-Generation Dark Matter Detectors (opens in a new tab)

  11. Design and implementation of a reconfigurable data acquisition integrated circuit

    … engineers have attempted to develop electronic systems able to extract and process the real world signals and turn them into useful data. Initially this development was done using analog technology. However, since the digital signal processor has developed rapidly due to integrated circuit (IC) …

    vu-aus Download PDF for Design and implementation of a reconfigurable data acquisition integrated circuit (opens in a new tab)

  12. Design of an Extensible and Scalable Data Acquisition System for Pulse Shape Discrimination

    … a highly scalable, end-to-end data acquisition (DAQ) system for nuclear physics experiments that can be deployed in configurations ranging from a few to thousands of detector channels. The system is built as an extensible platform composed of modular 16-channel chipboards that support a wide …

    wustl Repository record for Design of an Extensible and Scalable Data Acquisition System for Pulse Shape Discrimination (opens in a new tab)

  13. Real-Time Health Monitoring System for Mast-Arm Sign Support Structures

    … sign support structure. The health monitoring system developed in this thesis effort includes a grouping of strain gages (full-bridge arrangements) positioned around the perimeter of the mast-arm tube to monitor wind-induced strain near the mast-arm connection weld toes. This data is …

    marquette Repository record for Real-Time Health Monitoring System for Mast-Arm Sign Support Structures (opens in a new tab)

  14. Control system and data acquisition for the remote monitoring of the personnel in the ATLAS experimental infrastructure at CERN

    … research is to develop and optimize the Control System (CS) and Data Acquisition (DAQ) System for the Personnel Safety System used in the ATLAS cavern. We propose a monitoring system to supervise the health status of the personnel and provide guidance during the performance of complex activities …

    greece Repository record for Control system and data acquisition for the remote monitoring of the personnel in the ATLAS experimental infrastructure at CERN (opens in a new tab)

  15. Three Generations of FPGA DAQ Development for the ATLAS Pixel Detector

    … Gate Array (FPGA)-based readout systems that span across three major tasks of the ATLAS Pixel data acquisition (DAQ) system. The evolution of Pixel DAQ’s Readout Driver (ROD) card is presented. Starting from improvements made to the new Insertable B-Layer (IBL) ROD design, which …

    washington Repository record for Three Generations of FPGA DAQ Development for the ATLAS Pixel Detector (opens in a new tab)

  16. Characterization of a Low-Cost Millinewton Force Sensor for Ionic Polymer Metal Composite Actuators

    … expensive force sensors and data acquisition (DAQ) systems. This thesis explores the capabilities of a low cost, two dimensional millinewton force sensor fabricated out of nitinol #1 wire and orthogonally mounted strain gauge pairs in half bridge configurations. An Arduino microcontroller based …

    rit Repository record for Characterization of a Low-Cost Millinewton Force Sensor for Ionic Polymer Metal Composite Actuators (opens in a new tab)

  17. Implementing a Data Acquisition System for the Training of Cloud Coverage Neural Networks

    … array in the California State University (CSU) system, and it was claimed to be able to produce approximately 11 GWh per year. These types of projections come from power generation models which have been developed to predict power production of these large solar fields. However, when it comes to …

    calpoly Repository record for Implementing a Data Acquisition System for the Training of Cloud Coverage Neural Networks (opens in a new tab)

  18. Laser modification for the increased lifetime of a commercial Stainless-Steel Alloys

    … and performance of Pulsed Electric Field (PEF) systems. PEF systems use electromagnetic pulses to lyse bacterial cell walls for food pasteurization. However, electrode corrosion and biofouling pose challenges. This study investigates laser-induced oxidation to mitigate metal ion release during …

    dcu Download PDF for Laser modification for the increased lifetime of a commercial Stainless-Steel Alloys (opens in a new tab)

  19. Wireless Sensing System for Load Testing and Rating of Highway Bridges

    … Traditional wired sensors and data acquisition (DAQ) systems suffer drawbacks of being labor intensive, high cost, and time consumption in installation and maintenance. For those reasons, very few load tests have been conducted on bridges.;This study aims at developing a low-cost wireless bridge …

    wvu Repository record for Wireless Sensing System for Load Testing and Rating of Highway Bridges (opens in a new tab)

Page 1 of 3