Forensic analysis of plant based drugs of abuse by DART-MS
… Direct Analysis in Real Time-Mass Spectrometry (DART-MS) and to apply the methods in an effort to differentiate between multiple strains of a single seed species. DART is an ambient ionization technique that allows for rapid analysis of samples while eliminating the need for sample preparation …
-
Principal component analysis of gasoline DART-MS data for forensic source attribution
… Direct analysis in real time-mass spectrometry (DART-MS) has had increasing popularity in the field of forensic chemistry for chemical analysis, and it has been applied to fire debris analysis. DART-MS has great capacity for gasoline source attribution due to its ionization technique and …
-
Principal component analysis of gasoline DART-MS data in the low-mass region
… Direct Analysis in Real Time–Mass Spectrometry (DART-MS) and Principal Component Analysis (PCA). The mechanism of DART used in this research generates protonated intact molecular cations through proton transfer, and is much more efficient at detecting additives than electron impact with Gas …
-
Characterization of short chain fatty acids in microbial cultures by DART-MS and GC-MS
… of mono- and co-cultures in in vitro systems has led to the conclusion that diverse microbial organisms may each contribute in part to the complete metabolism to produce SCFA. GC- MS and DART- MS were investigated as analytical tools in the present study to evaluate the production of …
-
Chemometric classification of ignitable liquids using direct analysis in real time – mass spectrometry (DART-MS)
The use of DART-MS in the field of forensic science has attracted a lot of interest due to its rapid ionization and minimal sample preparation requirements. This study focused on coupling the use of DART as the ionization source to a mass spectrometer and analyzing the data acquired using the …
-
Measurement of denatonium benzoate in antifreeze with quantitative DART-MS method development and abbreviated method validation
… DB to be added to discourage ingestion. The EVOQ DART-TQ+® was used to develop and optimize a method for quantitative Direct Analysis in Real Time (DART) with a triple quadrupole mass spectrometer (MS), which was validated by considering accuracy, calibration model, limit of detection (LOD), lower …
-
Optimization of activated carbon cloth for the recovery of gasoline: analysis by GC-MS and DART-MS
… and Gas Chromatography-Mass Spectrometry (GC-MS). Currently, a jar of 100 ACS costs $720.00 with no other commercially available alternatives. Other cost-effective adsorbent technologies such as Activated Carbon Cloth (ACC) should be explored along with analysis by Direct Analysis in Real …
-
Rapid differentiation of hemp and marijuana with direct analysis in real time – mass spectrometry (DART-MS) and chemometrics analysis
… direct analysis in real time–mass spectrometry (DART-MS) with chemometrics analysis. DART is a rapid ambient ionization technique requiring minimal to no sample preparation. In this study, ten hemp and ten marijuana samples were extracted in methanol and analyzed in duplicate using DART-MS. To …
-
A method optimization and abbreviated validation of the analysis of NPS opioids in whole blood using quantitative DART-MS
… Direct Analysis in Real Time Mass Spectrometry (DART-MS) that can analyze NPS Opioids in whole blood. The results of the research showed that the method passed validation for all analytes, except for Heroin. A calibration model was designed with a linear range of 50-1000 ng/mL. The accuracy and …
-
Exploring Applicability of Direct Analysis in Real Time with Mass Spectrometry (DART-MS) to Identify Homemade Explosive Residues Post-Blast
Application of Direct-Analysis-in-Real-Time (DART) ionization with mass spectrometry (DART-MS) to identify explosives from post-blast residues is presented. Explosives studied represent current threats encountered in criminal investigations: homemade organic peroxides, binary explosives and …
-
Optimization And Validation Of Direct Analysis In Real Time Mass Spectrometry (dart-Ms) For Quantitation Of Sugars To Advance Biofuel Production
… Direct Analysis in Real Time Mass Spectrometry (DART-MS), an ambient mass spectrometric method described in this study, can readily analyze these generated simple sugars. ii) Optimization of DART-MS for the quantitation of glucose: Being the first study to use DART-MS to quantify sugars, the …
-
CHEMICAL STRUCTURE ELUCIDATION OF AN UNKNOWN COMPOUND BY DIRECT ANALYSIS IN REAL-TIME MASS SPECTROMETRY AND NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY
Direct Analysis in Real-Time Mass Spectrometry (DART-MS) and Nuclear Magnetic Resonance (NMR) are two analytical techniques that are most used in structural chemistry and biology. DART-MS measures mass to charge ratio of different compounds in a solution. From the mass to charge ratio, the chemical …
-
High-throughput analysis using novel sample preparation method and direct analysis in real time mass spectrometry
… direct analysis in real time mass spectrometry (DART-MS) has been shown to be a promising solution to trace analysis of compounds in complex matrices. In Chapter 1, a technical introduction of DART-MS and a review of some of the most common sample preparation techniques in trace analysis are …
-
Source attribution of trace gasoline additives by direct analysis in real time - mass spectrometry
… analysis in real time – mass spectrometry (DART-MS) to assess the feasibility to generate unique mass spectral data whereas prior gas chromatography – mass spectrometry (GC-MS) based efforts have been unable to. Traditional GC-MS methods generate chromatograms and mass spectral data which …
-
Acquiring chemical attribute signatures for gasoline: differentiation of gasoline utilizing direct analysis in real time - mass spectrometry and chemometric analysis
… analysis in real time – mass spectrometry (DART-MS) is evaluated as a potential method that could better identify, distinguish and classify gasoline brands from one another. Techniques such as DART-MS could enable forensic laboratories to better identify questioned gasoline samples. Many …
-
Novel Extractions of Trace-Level Compounds using PDMS Sorbent Polymers for High-Throughput Analyses and Mass Spectral Imaging
… taint exposure, characterize breeding programs, etc. Solid phase microextraction (SPME) is widely used in conjunction with gas chromatography-mass spectrometry (GC-MS) for volatile analyses in foodstuffs and other complex matrices. However, standard GC-MS quantitation methods generally …
-
Evaluating the feasibility of implementing direct analysis in real time - mass spectrometry for the forensic examination of post-blast debris
… Gas Chromatography – Mass Spectrometry (GC-MS), Liquid Chromatography – Mass Spectrometry (LC-MS), and Ion Mobility Spectrometry (IMS). Each instrument has benefits in the analytical results obtained. Direct Analysis in Real Time - Mass Spectrometry (DART-MS) has shown a significant promise …
-
VISUALIZING AROMA: SPATIALLY RESOLVED, HIGH-THROUGHPUT, AND AUTOMATED DETECTION OF ODORANTS IN GRAPES USING AMBIENT IONIZATION MASS SPECTROMETRY
… headspace of a sample. By laser-etching thin films of polydimethylsiloxane, SPMESH Sheets could be made to fit on multi-well plates. This allowed for extraction and pre-concentration of 24 samples in parallel, followed by automated analysis by Direct Analysis in Real Time mass spectrometry, or …
-
Developments and applications of solid phase microextraction (SPME) coupled to direct analysis in real time (DART) and approaches towards small volume analysis
… of SPME to Direct Analysis in Real Time (DART), an ambient ionization mass spectrometry (AIMS) technique. AIMS techniques completely eliminate the use of chromatography, reducing lengthy workflows and improving time-efficiency. SPME coupled to DART-MS has been quite successful in achieving …
-
Detecting drugs of abuse in human breast milk using biocompatible solid phase microextraction and direct analysis in real time mass spectrometry
… direct analysis in real time mass spectrometry (DART-MS). Adapting DART-MS to detect drugs of abuse in human breast milk will allow for quick and timely identification of drugs present in an individual’s breast milk, as well as aid in research regarding the potential harmful effects of …