Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 249 for “"DC bus"”.

  1. Ac-dc Bus-interface Bi-directional Converters in Renewable Energy Systems

    … covers several issues related to the ac-dc bus-interface bi-directional converters in renewable energy systems. The dissertation explores a dc-electronic distribution system for residential and commercial applications with a focus on the design of an ac-dc bi-directional converter for …

    vt Repository record for Ac-dc Bus-interface Bi-directional Converters in Renewable Energy Systems (opens in a new tab)

  2. DC Bus Stabilization and Dynamic Performance Improvement of a Multi-Converter System

    … AC systems to more efficient and reliable DC systems. Some examples are shipboard power distribution systems, DC microgrids, electric vehicles and more electric aircrafts. Even though these types of systems offer significant advantages that make them attractive in different areas, the …

    south-carolina Repository record for DC Bus Stabilization and Dynamic Performance Improvement of a Multi-Converter System (opens in a new tab)

  3. Impact analysis of motor faults on the DC Bus in electric vehicle drivetrains

    … Extended Park's Vector Approach (EVPA), and DC bus current analysis. The objective of this study was to analyse the effects of various faults and their manifestation on the DC bus of powertrains, specifically under transient speed conditions. The analysis of the results presented in this …

    cape-town Repository record for Impact analysis of motor faults on the DC Bus in electric vehicle drivetrains (opens in a new tab)

  4. Modular, Scalable Battery Systems with Integrated Cell Balancing and DC Bus Power Processing

    Traditional electric vehicle and stationary battery systems use series-connected battery packs that employ centralized battery management and power processing architecture. Though, these systems meet the basic safety and power requirements with a simple hard- ware structure, the approach results in …

    utahstate Repository record for Modular, Scalable Battery Systems with Integrated Cell Balancing and DC Bus Power Processing (opens in a new tab)

  5. Analysis and Design of LLC Resonant Converters for Wide, Low-input, High-output DC Bus Applications

    … with microinverter and batteries require DC/DC converters with a wide voltage range capabilities in order to fulfil the wide voltage system requirements. It has been shown that the LLC resonant converter is a good solution for wide voltage range applications because it is typically …

    ucf Repository record for Analysis and Design of LLC Resonant Converters for Wide, Low-input, High-output DC Bus Applications (opens in a new tab)

  6. Investigation into power distribution _grid interfacing for subsea tidal generation - Rectification to a common DC-bus

    … to as “passive rectification to a common DC-bus” where an array of 3-phase synchronous generators operating at diverse speeds are connected to a common DC bus via passive diode rectifiers. The proposed tidal stream topology shows that variable pitched blades, variable speed gearboxes and …

    whiterose Download PDF for Investigation into power distribution _grid interfacing for subsea tidal generation - Rectification to a common DC-bus (opens in a new tab)

  7. Implementation of a 100kW Soft-Switched DC Bus Regulator Based on Power Electronics Building Block Concept

    … of a 100kW PEBB-based soft-switched bus regulator for an 800V DC distributed power system. The zero current transition (ZCT) soft-switching technique is used to improve the performance of the bus regulator by minimizing switching loss and improving overall efficiency. PEBB modules and …

    vt Repository record for Implementation of a 100kW Soft-Switched DC Bus Regulator Based on Power Electronics Building Block Concept (opens in a new tab)

  8. Control Optimization and Adaptive Tuning of Droop Controlled Systems for DC Bus Stability via Terminal Impedance Shaping

    … traditional AC systems have been moving towards DC in recent decades due to advancements in power electronics and semiconductor devices. DC power distribution systems, such as DC microgrids, have become increasing popular due to energy efficiency, resiliency, and renewable energy integration. …

    south-carolina Repository record for Control Optimization and Adaptive Tuning of Droop Controlled Systems for DC Bus Stability via Terminal Impedance Shaping (opens in a new tab)

  9. Operation of a single-phase grid connected inverter with large DC bus voltage ripple for distributed generation

    … large electrolytic capacitors required at the dc bus for attenuating the 2 nd order voltage ripple. This Thesis discusses a control scheme suitable for the VSI operating with large dc bus ripple, when a small and high reliability thin film capacitor can be used. It is based on a dc bus voltage …

    concordia Download PDF for Operation of a single-phase grid connected inverter with large DC bus voltage ripple for distributed generation (opens in a new tab)

  10. Analysis of system wide distortion in an integrated power system utilizing a high voltage DC bus and silicon carbide power devices

    … distribution system for a high voltage DC Integrated Power System (IPS). The analysis was concentrated on the power supplied to a propulsion motor driven by an inverter with simulated silicon carbide switches. Theoretically, silicon carbide switches have the advantage of being able to …

    nps Repository record for Analysis of system wide distortion in an integrated power system utilizing a high voltage DC bus and silicon carbide power devices (opens in a new tab)

  11. Enhancing Efficiency in Residential PV Systems: Novel Maximum Power Point Tracking Strategy for Reduced DC Bus Capacitance in Differential Power Processing Architecture

    … to maximize power extraction, for which DC-DC converters are a common choice. Differential Power Processing (DPP) architectures can achieve higher efficiencies and lower cost by reducing the amount of power passing through these converters, while still providing Maximum Power Point …

    calgary Repository record for Enhancing Efficiency in Residential PV Systems: Novel Maximum Power Point Tracking Strategy for Reduced DC Bus Capacitance in Differential Power Processing Architecture (opens in a new tab)

  12. Single phase grid tie inverter for solar PV panels with active power decoupling circuit

    … component of the grid that appears on the DC bus link. Large electrolytic capacitors are generally employed in the inverters to eliminate the ripple component. However, their bulkiness and relatively short lifetime are motivational factors to replace them with small film capacitors. This …

    texas Repository record for Single phase grid tie inverter for solar PV panels with active power decoupling circuit (opens in a new tab)

  13. Control of a Single-Phase Grid-Connected Voltage Source Inverter with LCL Filter

    … that need to be designed: an external DC-bus voltage controller to balance the power flow coming into the VSI, and an internal current controller to control the current injected by the VSI into the utility grid. This thesis aims to find well-tailored control approaches for the …

    queens Repository record for Control of a Single-Phase Grid-Connected Voltage Source Inverter with LCL Filter (opens in a new tab)

  14. Control of Asymmetric Permanent Magnet Synchronous Generator Systems

    … suppression of its second harmonic (2h) power, DC bus voltage and torque ripples. The asymmetries include the unbalanced resistances, unbalanced inductances, and unbalanced 3-phase back-electromotive forces (EMFs). The mathematical model of the general asymmetries in the PMSG system is firstly …

    whiterose Download PDF for Control of Asymmetric Permanent Magnet Synchronous Generator Systems (opens in a new tab)

  15. Reduction of current/torque ripple in low power grid-tie PMSG wind turbines

    … loading produced by grid-tie inverters on the DC bus is different than more typical constant-current or constant-power loads. They are characterized by large input ripple currents at twice the inverter's grid frequency. These ripple currents are reflected through the DC bus into the PMSG …

    ubc Repository record for Reduction of current/torque ripple in low power grid-tie PMSG wind turbines (opens in a new tab) Download PDF for Reduction of current/torque ripple in low power grid-tie PMSG wind turbines (opens in a new tab)

  16. Coordinated energy management and converter control strategies for fuel cell-supercapacitor hybrid energy storage systems

    … The hybrid system is connected to a regulated DC-bus through dual active bridge (DAB) converters. The work addresses five connected research problems: dynamic load compensation, controlled SC recovery, charging-path architecture, reduced-order modelling and small-signal stability assessment of …

    aalto Repository record for Coordinated energy management and converter control strategies for fuel cell-supercapacitor hybrid energy storage systems (opens in a new tab)

  17. Evaluation of Active Capacitor Banks for Floating H-bridge Power Modules

    The DC-side floating capacitors in the floating power modules of power converters are subject to high voltage fluctuation, due to the presence of reactive harmonic components. Utilizing passive capacitors, as done in traditional methods, helps reduce the DC-bus voltage ripple but makes the system …

    vt Repository record for Evaluation of Active Capacitor Banks for Floating H-bridge Power Modules (opens in a new tab)

  18. Series DC Arc Fault Detection for a Grid-Tie Solar PV Power Generation System

    … is developed for the detection of series dc arc faults in a grid-tie solar photovoltaic (PV) installation. The sensed dc bus current, which is sampled using an analog-to-digital converter with Galvanic isolation, is filtered using a wavelet-based, two-level filter bank. The filter bank, …

    vt Repository record for Series DC Arc Fault Detection for a Grid-Tie Solar PV Power Generation System (opens in a new tab)

  19. Design and development of a traction motor emulator using a three-phase bidirectional buck-boost AC-DC converter

    … ME comprises of two-stage three-phase AC-DC-AC conversion with first-stage AC-DC as emulator and second-stage DC-AC as regenerating unit. This two-stage power conversion, require independent control algorithm, burdening control complexity as well as the number of power electronic switches …

    uoit Repository record for Design and development of a traction motor emulator using a three-phase bidirectional buck-boost AC-DC converter (opens in a new tab)

Page 1 of 13