Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 6 of 6 for “"DCLC"”

  1. Calcul de chemins pour réseaux IP : routage de la patate chaude et froide lors de pannes & chemins multi-contraints pour segment routing

    … faible. Le problème NP-Difficile étudié, appelé DCLC, devient radicalement plus complexe lorsque l'on considère les contraintes opérationnelles rajoutées par la technologie utilisée pour déployer ces chemins, Segment Routing. Nous proposons différents méthodes et algorithmes afin de résoudre DCLC …

    star-france Repository record for Calcul de chemins pour réseaux IP : routage de la patate chaude et froide lors de pannes & chemins multi-contraints pour segment routing (opens in a new tab)

  2. Organic pi-stacking Semiconducting Material: Design, Synthesis and the Analysis of Structure and Properties

    … of the discotic columnar liquid crystalline (DCLC) phase. Chapter 2 describes a DCLC phase with a novel hierarchical structure in which each supra-molecular column features a bundled-stack structure. The molecular design rationale was explained and the thermal behavior and phase structure were …

    cuny-grad Repository record for Organic pi-stacking Semiconducting Material: Design, Synthesis and the Analysis of Structure and Properties (opens in a new tab)

  3. Genètica de la Butirilcolinesterasa en les sinucleïnopaties: Establiment d'una eina pel diagnòstic diferencial de la demència amb cossos de Lewy

    … DCL de tipus pur, DCLp; DCL de tipus comuna, DCLc) i a les inclusions citoplasmàtiques glials, que són la característica neuropatològica de l'atròfia multisistèmica (AMS). D'altra banda, les plaques senils formades principalment per β-amiloide i cabdells neurofibril·lars amb tau …

    barcelona Repository record for Genètica de la Butirilcolinesterasa en les sinucleïnopaties: Establiment d'una eina pel diagnòstic diferencial de la demència amb cossos de Lewy (opens in a new tab)

  4. Holistic Study of Thermal Management in Direct Liquid Cooled Data Centres: from the Chip to the Environment

    … Toward this goal, Direct Contact Liquid Cooled (DCLC) servers, where liquid loop heat exchangers are attached to the CPU, were proposed to study the use of chiller-less energy efficient data centre. Thirty Sun Fire V20z servers in a data centre rack have their CPUs water cooled with the remaining …

    whiterose Repository record for Holistic Study of Thermal Management in Direct Liquid Cooled Data Centres: from the Chip to the Environment (opens in a new tab)

  5. EFFICIENT ENHANCEMENT OF MICRO-NUCLEATION RATES IN FLOW-BOILING - BY CONCURRENT MICRO-STRUCTURING OF THE BOILING-SURFACE AND ITS JUDICIOUS ENERGIZATION BY PIEZOELECTRIC-TRANSDUCER INDUCED ACOUSTIC VIBRATIONS.

    … water-based Direct Contact Liquid Cooling (DCLC) or Direct to Chip (D2C) liquid cooling approaches, heat transfer efficiency goes up by 700%, driving temperature difference goes down by 80-90%, maximum allowed average heat-flux goes up from about 35 W/cm2 to more than 70 – 100 W/cm2, and …

    mtu Repository record for EFFICIENT ENHANCEMENT OF MICRO-NUCLEATION RATES IN FLOW-BOILING - BY CONCURRENT MICRO-STRUCTURING OF THE BOILING-SURFACE AND ITS JUDICIOUS ENERGIZATION BY PIEZOELECTRIC-TRANSDUCER INDUCED ACOUSTIC VIBRATIONS. (opens in a new tab)

  6. Mechanisms for quality-of-service provisioning in networks with extended services

    … can be regarded as a delay-leastl-ow-cost (DCLC) problem, which is known to be NP-hard. An improved k-shortest path QoS routing algorithm is proposed to solve this problem.

    njit Repository record for Mechanisms for quality-of-service provisioning in networks with extended services (opens in a new tab)