Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 146 for “"DFIG"”.

  1. Control Studies of DFIG based Wind Power Systems

    … This also gives the plug-and-play feature of DFIG controllers to make it promising in utility practices.</p> <p>Another key challenge in power regulation of wind energy is the control design in wind energy conversion system (WECS) to realize the tradeoff between the energy cost and control …

    utk-theses Repository record for Control Studies of DFIG based Wind Power Systems (opens in a new tab)

  2. DFIG-Based Split-Shaft Wind Energy Conversion Systems

    … and uses a Doubly-Fed Induction Generator (DFIG) instead of a synchronous generator. This type of wind turbine provides several benefits, including decoupling the shaft speed controls at the turbine and the generator. Hence, maintaining the generator’s frequency and seeking maximum power …

    iupui Repository record for DFIG-Based Split-Shaft Wind Energy Conversion Systems (opens in a new tab)

  3. Damping Interarea Oscillations in Power Systems with DFIG

    … increasing. The doubly fed induction generator (DFIG) is the most widely used generator for wind energy conversion because of its various advantages over other types of generators. In a DFIG, the rotor is fed through back to back converters via slip rings. The converters enable the generation …

    ndsu Repository record for Damping Interarea Oscillations in Power Systems with DFIG (opens in a new tab)

  4. DFIG Based Wind Turbine Contribution to System Frequency Control

    … operation of the Doubly Fed Induction Generator (DFIG) with a modified inertial loop control considering single-area and two-area frequency control, both primary control and AGC. The thesis presents new, small-perturbation, linear, dynamic, mathematical models for the simulation of primary …

    waterloo Repository record for DFIG Based Wind Turbine Contribution to System Frequency Control (opens in a new tab)

  5. DFIG Based Wind Turbine System For Clemson Micro-grid

    … devices. A doubly fed induction generator (DFIG) based wind turbine (WT) is the main power source of the presented project. The DFIG system is connected to the three phase AC grid via back-to-back power converter and an LCL filter. Decoupled q-d control strategies are investigated for the …

    clemson Repository record for DFIG Based Wind Turbine System For Clemson Micro-grid (opens in a new tab)

  6. Incorporating DFIG-Based Wind Power Generator in Microgird Frequency Stabilization

    … connected to the Doubly Fed Induction Generator (DFIG) shaft or a super-capacitor connected to the DC-link on a back-to-back converter of a wind power generator could be used. The concept and the proposed control methods are discussed in detail, and eigen-value analysis is used to study how the …

    waterloo Repository record for Incorporating DFIG-Based Wind Power Generator in Microgird Frequency Stabilization (opens in a new tab)

  7. The Protection of Transmission Lines Connected to DFIG-Based WTGs

    … connected to doubly-fed induction generator (DFIG)-based wind turbine generators (WTGs). DFIG-based WTGs, or namely Type III WTGs, which connect to the power systems via reduced-size converters, raise additional protection challenges such as the maloperation of distance relays due to the …

    waterloo Repository record for The Protection of Transmission Lines Connected to DFIG-Based WTGs (opens in a new tab)

  8. Model Predictive Control of DFIG-Based Wind Power Generation Systems

    … equipped with doubly fed induction generators (DFIGs). At the wind turbine control level, a multivariable control strategy based on model predictive control techniques is proposed. The proposed strategy is formulated for the whole operating region of the wind turbine, i.e., both partial and full …

    calgary Repository record for Model Predictive Control of DFIG-Based Wind Power Generation Systems (opens in a new tab)

  9. Integration improvement of DFIG-based wind turbine into the electrical grid

    … Through (FRT) capability of the Grid-connected DFIG-based Wind Turbine. The first proposed approach is a hybrid method combining two methods (active and passive methods): The active method aims to develop the control of DFIG. In contrast, the passive method is applied for severe voltage faults …

    upc-spain Repository record for Integration improvement of DFIG-based wind turbine into the electrical grid (opens in a new tab)

  10. State-Plane Modelling and Control of a DFIG-based Wind Turbine

    Doubly Fed Induction Generator (DFIG) based wind turbines are particularly sensitive to grid disturbances, which has implications for overall power system stability. Grid codes require continual operation of the DFIGs despite certain system disturbances. During a three-phase voltage dip, the decay …

    calgary Repository record for State-Plane Modelling and Control of a DFIG-based Wind Turbine (opens in a new tab)

  11. Sub-synchronous controller interaction (SSCI) of series-compensated DFIG wind farms

    … with the control system of the connected DFIG wind farm, thus causing the system (under certain conditions) to experience unstable resonant oscillations at the subsynchronous frequency range. This thesis studies the sub-synchronous controller interaction (SSCI) of DFIG-based wind-farms …

    chalmers Repository record for Sub-synchronous controller interaction (SSCI) of series-compensated DFIG wind farms (opens in a new tab)

  12. Modelling and Simulation of DFIG for wind energy applications using PWM converters

    … in wind energy conversion system applications. DFIG is one of the most common machines in modern wind power generation because of its capability to operate efficiently for a wide range of wind speeds. The design of the system consists of two back-to-back connected PWM converters through a dc …

    washington Repository record for Modelling and Simulation of DFIG for wind energy applications using PWM converters (opens in a new tab)

  13. IMPACT OF DFIG-BASED WIND FARMS ON GENERATOR DISTANCE PHASE BACKUP PROTECTION

    … the effect of Doubly-Fed Induction Generator (DFIG)-based wind farms on the performance of generator distance phase backup protection element (Relay (21)) in order to identify important issues that protection engineers need to consider when designing and setting a generator protection system. …

    sask Repository record for IMPACT OF DFIG-BASED WIND FARMS ON GENERATOR DISTANCE PHASE BACKUP PROTECTION (opens in a new tab)

  14. Controle de amortecimento de oscilações eletromecânicas utilizando unidades eólicas do tipo DFIG

    … converter (active power grid or Reactive) of the DFIG wind units. The simulations were performed through the CEPEL programs: ANAREDE (Analysis of Electrical Networks) and ANATEM (Analysis of Electromechanical Transients) in three test systems.

    brazil-uerj Repository record for Controle de amortecimento de oscilações eletromecânicas utilizando unidades eólicas do tipo DFIG (opens in a new tab)

  15. Evaluation of the DFIG wind turbine built-in model in PSS/E

    … needed. The purpose of this study is to evaluate DFIG wind turbine built-in model in PSS/E. In this report, the responses of the model subjected to grid disturbances are investigated. At first, the typical dynamic model of a DFIG wind turbine is introduced. Secondly the built-in dynamic model for …

    chalmers Repository record for Evaluation of the DFIG wind turbine built-in model in PSS/E (opens in a new tab)

  16. Análise em regime permanente de parques eólicos com máquinas SCIG e DFIG

    … alimentado (Doubly-Fed Induction Generator-DFIG) e o de velocidade fixa com gerador de indução de rotor de gaiola de esquilo (Squirrel Cage Induction Generator-SCIG). O caso de estudo está baseado no parque eólico Jepirachi na Colômbia, o qual na atualidade tem aerogeradores de velocidade …

    brazil-ufrgs Repository record for Análise em regime permanente de parques eólicos com máquinas SCIG e DFIG (opens in a new tab)

  17. Dynamic integration of a grid connected DFIG wind turbine with a fuel cell

    Includes bibliographical references (pages 124-127).

    colo-mines Repository record for Dynamic integration of a grid connected DFIG wind turbine with a fuel cell (opens in a new tab)

  18. Modelagem dinâmica e controle de um gerador tipo DFIG em redes de distribuição

    … o gerador de indução duplamente alimentado (DFIG). Sua importância é principalmente o controle independente da potência ativa e da potência reativa fornecida para a rede elétrica, e à operação com máxima eficiência na conversão de energia. Neste contexto, este trabalho apresenta uma análise …

    brazil-ufrgs Repository record for Modelagem dinâmica e controle de um gerador tipo DFIG em redes de distribuição (opens in a new tab)

  19. Improved Dynamical Analysis Tools for DFIG Wind Farms via Traditional and Koopman Linearizations

    The electric power system is designed to economically and reliably transmit electricity to homes, industry, and businesses. The economic impact of the electric grid was demonstrated by the 2003 blackout's visible impact in the graph of the yearly gross domestic product of the Unites States. …

    vt Repository record for Improved Dynamical Analysis Tools for DFIG Wind Farms via Traditional and Koopman Linearizations (opens in a new tab)

Page 1 of 8