Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 34 for “"DOLP"”

  1. Understanding the role of the lipoprotein DolP in cell envelope Biogenesis

    … aim of this thesis is to study the lipoprotein, DolP (formerly YraP) and its role in the cell envelope biogenesis of the Gram-negative bacterium Escherichia coli. DolP is a dual-BON domain lipoprotein localised in the OM. Studies have suggested that DolP might be a component of the BAM (β-barrel …

    birmingham Repository record for Understanding the role of the lipoprotein DolP in cell envelope Biogenesis (opens in a new tab)

  2. Mécanismes de biogenèse et de maintenance de la membrane externe de bactéries Gram-négatives

    … on trouve les protéines de l'enveloppe DolP/YraP et TamB qui ont été étudiées au cours de cette thèse. DolP est une lipoprotéine mal caractérisée, régulée positivement lors de l'activation de la réponse au stress de l'enveloppe. Elle est constituée de deux domaines bacterial OsmY and …

    star-france Repository record for Mécanismes de biogenèse et de maintenance de la membrane externe de bactéries Gram-négatives (opens in a new tab)

  3. ENHANCED MULTISPECTRAL POLARIMETRIC IMAGING TECHNIQUES UTILIZING AN OPTICAL TUMOR PHANTOM

    … to calculate the Degree of Linear Polarization (DOLP) image. Then, the DOLP images obtained from the two different wavelength lasers were subtracted to enhance the information present in the image. The Signal-to-Background ratio, a measure of contrast, was calculated to determine the quality of …

    ohiolink Repository record for ENHANCED MULTISPECTRAL POLARIMETRIC IMAGING TECHNIQUES UTILIZING AN OPTICAL TUMOR PHANTOM (opens in a new tab)

  4. Study of Biomolecular Optical Signatures for Early Disease Detection and Cell Physiology Monitoring

    … The resulting Degree of Linear Polarization (DOLP) images were analyzed for contrast differences and the image quality was assessed by computing Signal-to-Background Ratios (SBRs) for every concentration of molecular contrast agent added to the surrounding medium of the target. The second …

    ohiolink Repository record for Study of Biomolecular Optical Signatures for Early Disease Detection and Cell Physiology Monitoring (opens in a new tab)

  5. Mécanismes de biogenèse et de maintien de la membrane externe des bactéries à Gram négatif

    … putatifs du complexe BAM, les lipoprotéines DolP (anciennement YraP) et YifL, toutes deux de fonctions inconnues. L'objectif de ce travail de thèse était de caractériser les rôles respectifs de DolP et YifL au sein du complexe BAM. DolP est une lipoprotéine de la ME de 20 kDa. L’accumulation …

    star-france Repository record for Mécanismes de biogenèse et de maintien de la membrane externe des bactéries à Gram négatif (opens in a new tab)

  6. Image Contrast Enhancement Using Biomolecular Photonic Contrast Agents and Polarimetric Imaging Principles

    … Stokes parameters are calculated and finally the DOLP images are calculated. The obtained S0 and DOLP images are fused to get a fused image with higher details. This step is followed for each concentration of optically active molecular contrast agents added to the preclinical phantom. The mean …

    ohiolink Repository record for Image Contrast Enhancement Using Biomolecular Photonic Contrast Agents and Polarimetric Imaging Principles (opens in a new tab)

  7. Image Contrast Enhancement using Biomolecular Photonic Contrast Agents and Polarimetric Imaging Principles

    … and finally the Degree of Linear Polarization (DOLP) images were calculated. The obtained S0 and DOLP images were fused to obtain an enhanced image which offers a high contrast resolution. This step was repeated for each concentration of optically active molecular contrast agents added to the …

    ohiolink Repository record for Image Contrast Enhancement using Biomolecular Photonic Contrast Agents and Polarimetric Imaging Principles (opens in a new tab)

  8. Infrared Polarimetry for Remote Sensing

    … both the AoLP and Degree of Linear Polarization (DoLP) of cold targets. Lab validation studies have demonstrated polarimetric sensitivity to targets with 1.0% DoLP and brightness temperatures of less than 270 K. In 2021, the IRCSP was demonstrated in the near-space environment as a piggyback out …

    arizona-thes Repository record for Infrared Polarimetry for Remote Sensing (opens in a new tab)

  9. Stokes parameters of skylight based on simulations and polarized radiometer measurements

    … Besides the degree of linear polarization (DoLP) and the total radiance I, the parameters Q, U, and AoP have much potential to improve retrievals of aerosol microphysical and chemical properties. However, they have not been derived based on the CE318-DP so far because they change with the …

    qucosa-diss Repository record for Stokes parameters of skylight based on simulations and polarized radiometer measurements (opens in a new tab)

  10. In Vitro Biomarker Detection for Early Diagnosis of Neurodegenerative Diseases via the Ocular Fluid

    … the corresponding Degree of Linear Polarization (DOLP) were calculated. Backscattering geometry detected light from the surface and subsurface of the tissue (epithelium), therefore it was anticipated to be highly polarized. Diffused reflectance geometry detected light from deeper structures …

    ohiolink Repository record for In Vitro Biomarker Detection for Early Diagnosis of Neurodegenerative Diseases via the Ocular Fluid (opens in a new tab)

  11. MULTIANGLE SPECTROPOLARIMETRIC IMAGER (MSPI)

    … and 0.005 degree of linear polarization (DoLP) uncertainty. These are difficult requirements that push the limits of available technologies needed to perform space-based polarimetric imaging. This work examines three topics related to MSPI fabrication and calibration: polarization errors …

    arizona-thes Repository record for MULTIANGLE SPECTROPOLARIMETRIC IMAGER (MSPI) (opens in a new tab)

  12. The influence of membrane lipids on glycosylation processes: Activity of Dpm1 in different lipid environments

    … catalyzes the synthesis of the mannosyl donor DolP Man which is required for all protein glycosylation routes. To investigate a role of membrane lipids in modulating the activity of Dpm1, I used a liposomal reconstitution system. I established a purification and liposomal reconstitution …

    heid-diss Repository record for The influence of membrane lipids on glycosylation processes: Activity of Dpm1 in different lipid environments (opens in a new tab)

  13. Modeling and simulation of adaptive multimodal optical sensors for target tracking in the visible to near infrared

    … plane detector. Degree of linear polarization (DoLP) imagery is acquired by combining three adjacent micropolarizer outputs within each 2x2 superpixel whose respective transmissions vary with wavelength, relative angle of polarization, and wire-grid spacing. A novel micromirror within each …

    rit Repository record for Modeling and simulation of adaptive multimodal optical sensors for target tracking in the visible to near infrared (opens in a new tab)

  14. DETECTION OF POLARIMETRIC SIGNATURES USING HIGH-EFFICIENCY POLARIMETRIC IMAGING TECHNIQUES

    … when applying the degree of linear polarization (DOLP) algorithm. Since significant results were established using polarimetric signals, the polarimetric algorithm was used to test the impact on the size of a target’s cross section. Using the range equation, we were able to improve the back …

    ohiolink Repository record for DETECTION OF POLARIMETRIC SIGNATURES USING HIGH-EFFICIENCY POLARIMETRIC IMAGING TECHNIQUES (opens in a new tab)

  15. Real-time non-destructive inspection and image analysis of carbon fibre orientation using polarisation vision

    … raw saturation, Degree of Linear Polarisation (DoLP), and fibre orientation images (in RGB and HSV formats) as real time video. In HSV, the hue channel encodes AoLP, and saturation encodes DoLP. The raw saturation image helps identify over- and underexposed areas, while the grayscale DoLP image …

    whiterose Repository record for Real-time non-destructive inspection and image analysis of carbon fibre orientation using polarisation vision (opens in a new tab)

  16. Hodnocení interního prostředí podniku a návrhy na zlepšení současné situace

    … na hodnocení vnitřního prostředí podniku DOLP, s.r.o. Interní analýza je založena zejména na využití nástrojů strategické a finanční analýzy vycházející ze zdrojů poskytnutých analyzovanou společností (interní materiály, finanční výkazy). Práce je rozdělena do tří částí. První část se …

    brno-tech Repository record for Hodnocení interního prostředí podniku a návrhy na zlepšení současné situace (opens in a new tab)

  17. Linear-Stokes Hyper Temporal Polarimeter for Long-Range Characterization of Vibrating Objects

    … quantified as the degree of linear polarization [DoLP] and the orientation of linear polarization is given as the angle of linear polarization [AoLP] for the incoherent sum across the observed bandwidth. Temporal imaging captures structural information with low noise at high speeds. With …

    arizona-thes Repository record for Linear-Stokes Hyper Temporal Polarimeter for Long-Range Characterization of Vibrating Objects (opens in a new tab)

  18. Řízení rizik projektu ve vybrané organizaci

    … částí je analýza současného stavu společnosti DOLP stavební společnost s.r.o., na kterou navazují další metody, jako je analýza vnitřního a vnějšího prostředí a závěrečná analýza SWOT, kde jsou zhodnoceny silné a slabé stránky, příležitosti a hrozby podniku. Na základě zhotovených analýz byla …

    brno-tech Repository record for Řízení rizik projektu ve vybrané organizaci (opens in a new tab)

  19. Synergy between ground-based remote-sensing instruments for retrieving microphysical-optical-radiative properties of atmospheric aerosols

    … addition of the Degree of Linear Polarization (DoLP) improved the noise-free and random-noise GRASP inversions, particularly under higher AOD. The gains were most notable for the coarse mode of the optical properties, and for the coarse mode of the Real Refractive Index. To achieve Obj. 2, a …

    barcelona Repository record for Synergy between ground-based remote-sensing instruments for retrieving microphysical-optical-radiative properties of atmospheric aerosols (opens in a new tab)

  20. An analysis of cryovolcano plumes on Enceladus by light scattering and polarimetry

    … disk-averaged degree of linear polarization (DoLP). The plume intensities and surface DoLP are compared to spherical, spheroidal, cylindrical, and hexagonal water ice particles simulated by light scattering codes Amsterdam Discrete Dipole Approximation (ADDA) and T-Matrix for both single …

    ksu Repository record for An analysis of cryovolcano plumes on Enceladus by light scattering and polarimetry (opens in a new tab)

Page 1 of 2