Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 51 for “"DPIV"”.
-
Time-Resolved Analysis of Circulation Control over Supercritical Airfoil using Digital Particle Image Velocimetry (DPIV)
… time accurate flow visualization technique (DPIV). Vorticity behavior was investigated using Tecplot® and a MATLAB® program was developed to quantify the Strouhal Number of time-averaged velocity fluctuations moving aft of the Coanda surface for each case.
-
Development of Robust Correlation Algorithms for Image Velocimetry using Advanced Filtering
Digital Particle Image Velocimetry (DPIV) is a planar measurement technique to measure the velocity within a fluid by correlating the motion of flow tracers over a sequence of images recorded with a camera-laser system. Sophisticated digital processing algorithms are required to provide a high …
-
Integration and Validation of Flow Image Quantification (Flow-IQ) System
… aim of this work was to test the performance of DPIV algorithms in wall shear flows, and to test the performance of several particle sizing algorithms for use in spray sizing and average diameter calculation. Several particle sizing algorithms which assume a circular particle profile were tested …
-
A Hybrid Dynamically Adaptive, Super-Spatio Temporal Resolution Digital Particle Image Velocimetry for Multi-Phase Flows
… resolution Digital Particle Image Velocimetry (DPIV) system with capability of resolving velocities in a multi-phase flow field, using a very sophisticated novel Dynamically Adaptive Hybrid velocity evaluation algorithm has been developed The unique methodology of this powerful system is …
-
Micromechanical Investigations of Foundation Structures-Granular Soil Interactions
… digital particle image velocimetry (DPIV) is used to measure the grain-scale (local scale) displacement fields, and they are used to characterise the failure envelopes of key footing-granular soil interaction problems. For the first time, such outcomes are generated in terms of the …
-
Geometry induced flow disturbances
… Digital Particle Image Velocimetry (DPIV) to compare the hemodynamic performance of two stents in a compliant vessel. The first stent was a rigid insert, representing an extreme compliance mismatch. The second stent was a commercially available nitinol stent with some flexural …
-
Experimental Investigation of the Effects of a Passing Shock on Compressor Stator Flow
… and Digital Particle Image Velocimetry (DPIV). Measurements were taken for three different shock strengths. In every case studied, a vortex formed near the stator trailing edge as the shock impacted the blade. The size of this vortex was shown to be directly related to the shock strength, …
-
An Investigation of Dolphin-Groove Inspired Surface Patterning on Flow Control
… digital particle image velocimetry (TR-DPIV) was used to track the development of the flow separation within the boundary layer and compared to the smooth plate (non-grooved) wall cases. The grooved surfaces form embedded vortices within the sinusoidal cavities which can lead to a …
-
Mixing at Low Reynolds Numbers by Vibrating Cantilevered Ionic Polymers
… tested and Digital Particle Image Velocimetry (DPIV) measurements were obtained. Resulting analysis using a quantitative mixing metric shows that using cantilevered polymers create increases mixing potential in the flow for some actuation cases. Although these differences are present, they do …
-
Subpixel Resolution Schemes for Multiphase Flows
… for Digital Particle Tracking Velocimetry (DPIV). The errors of these new methods were classified through Monte-Carlo simulations. These schemes provide direct measurements of the apparent particle image diameter and the subpixel position. The new methods significantly reduce the bias error …
-
A characterization of glucose-induced downregulation of the glucose dependent insulinotropic polypeptide receptor (GIPR)
… on the effects of the dipeptidyl peptidase (DPIV) inhibitor P32/98 and a DPIV-resistant analogue D-Ala²-GIP on VDF and ZDF rats respectively, showed only moderate improvements in glucose homeostasis, and therefore were not appropriate models for determining the potential reversal effects of …
-
Flow-induced sound and vibration due to the separated shear layer in backward-facing step and cavity configurations
… using digital particle image velocimetry (DPIV) in conjunction with unsteady pressure measurements. Global instantaneous, phase- and time-averaged flow images, as well as turbulence statistics, were evaluated to provide insight into the flow physics during flow tone generation. Onset of the …
-
The Development of a Novel in vitro Flow System to Evaluate Platelet Activation and Procoagulant Potential Induced by Bileaflet Mechanical Heart Valve Leakage Jets
… with digital particle image velocimetry (DPIV) measurements detailing flow fields for the same models. The significant findings were that: 1) recalcification of recirculating citrated blood markedly increases the magnitude of thrombus forming reactions and the sensitivity for their …
-
Multiphase Hydrodynamics in Flotation Systems
… using Digital Particle Image Velocimetry (DPIV). The experimental results were compared with the predictions from empirical and theoretical collision models. Time-resolved DPIV was used to measure the turbulent velocity field in a Rushton turbine around the impeller region. The turbulence …
-
Modification of Blade-Vortex Interactions Using Leading Edge Blowing
… using Digital Particle Image Velocimetry (DPIV) and accelerometer measurements in a time-resolved sense. The results indicate that LEB can significantly reduce the degree of unsteady loading due to the blade vortex interaction (BVI). In some cases, the LEB jet appears to break the coherency …
-
Laminar and Transitional Flow disturbances in Diseased and Stented Arteries
… using Digital Particle Image Velocimetry (DPIV), (b) Complex geometric effects of stented arteries with emphasis on its design parameters is investigated using CFD, Also (c) a novel method to improve the accuracy of velocity gradient estimation in the presence of noisy flow fields such as …
-
Analysis of near-surface flow measurements beneath clean and contaminated wind-driven water surfaces
… using digital particle image velocimetry (DPIV) and water surface temperature measurements were made simultaneously using infrared imagery. Results are reported for two wind speeds, 6.3 and 8.1 m s -1 . (Abstract shortened by UMI.)
-
Aerodynamics of a Heaving and pitching aerofoil
… dimensional Digital Particle Image Velocimetry (DPIV) was used to study the unsteady flows of a simplified flapping foil model, that of a heaving and pitching elliptical aerofoil. The aerofoil was subjected to a uniform free stream in a water tunnel with a constant low Reynolds number of 1000. …
-
Experimental investigation of bio inspired flapping wings for MAV and NAV applications
… the help of Digital Particle Image Velocimetry (DPIV) by which quantitative flow field measurements were made. The PIV results provide a greater understanding of the vortex structures which were generated due to high frequency flapping motion of the wings.</p>
-
The influence of granulation methods and particle size on pharmaceutical granules flowability using ring shear tester and particle image velocimetry
… called digital particle image velocimetry (DPIV) was used to understand the velocity distribution of the granular flow inside a typical case of silo with internal angles of 45° and 70°. The starch granules prepared by wet granulation showed better flowability than that prepared using melt …
Page 1 of 3