  1. TOWARD A MORE CLARIFIED DETECTIVE QUANTUM EFFICIENCY METHODOLOGY: STUDY OF THE DQE THEORY AND APPLICATIONS

    Detective quantum efficiency (DQE) is widely accepted as the golden rule to objectively evaluate the performance of x-ray imaging systems. It provides a comprehensive characterization of an x-ray imaging system, because it combines several important image-quality-related measurements such as …

    oklahoma-thes Repository record for TOWARD A MORE CLARIFIED DETECTIVE QUANTUM EFFICIENCY METHODOLOGY: STUDY OF THE DQE THEORY AND APPLICATIONS (opens in a new tab)

  2. Modeling of the frequency dependent detective quantum efficiency of X-ray imaging detectors

    … f , dependent detective quantum efficiency, DQE(f ). In this thesis, we have proposed a parallel cascaded linear system model for calculating DQE(f ) by considering the effects of K-fluorescence reabsorption, the range of primary photo electrons, charge carrier trapping, aperture function, …

    concordia Download PDF for Modeling of the frequency dependent detective quantum efficiency of X-ray imaging detectors (opens in a new tab)

  3. Comparative Performance Evaluation of Conventional and Folded Detector Structures for X-ray imaging

    … need high detective quantum efficiency (DQE) for getting clear X-ray image. The photoconductor layer thickness plays a very important role in conventional detector structure (i.e., a photoconductor layer is sandwiched between two electrodes where charges are collected in corresponding …

    concordia Download PDF for Comparative Performance Evaluation of Conventional and Folded Detector Structures for X-ray imaging (opens in a new tab)

  4. INFORMATION TRANSFER EFFICIENCY OF X-RAY IMAGE INTENSIFIER-BASED IMAGING SYSTEMS.

    … measure: the detective quantum efficiency {DQE(f)}, which is a function of the statistically independent frequency channels. The DQE(f) is a combined descriptor which takes into account the signal transfer as well as noise transfer properties of a complete system. For a complicated …

    arizona-thes Repository record for INFORMATION TRANSFER EFFICIENCY OF X-RAY IMAGE INTENSIFIER-BASED IMAGING SYSTEMS. (opens in a new tab)

  5. Αρχές λειτουργίας λαπαροσκοπικής απεικόνισης

    … την ανιχνευτική κβαντική αποδοτικότητα (DQE) της λαπαροσκοπικής απεικόνισης. Η μεταβολή του DQE θα μελετηθεί για διάφορες παραμέτρους των επιμέρους τμημάτων. Αρχικά θα περιγραφεί το θεωρητικό μοντέλο του γραμμικού συστήματος αξιολόγησης. Η υλοποίηση των αλγορίθμων υπολογισμού των …

    athens Repository record for Αρχές λειτουργίας λαπαροσκοπικής απεικόνισης (opens in a new tab)

  6. Modeling of x-ray photoconductors for x-ray image detectors

    … function (MTF), detective quantum efficiency (DQE), and ghosting of x-ray image detectors have been developed. The modeling works are based on the physics of the individual phenomena and the systematic solution of the fundamental physical equations in the photoconductor layer: (1) semiconductor …

    sask Repository record for Modeling of x-ray photoconductors for x-ray image detectors (opens in a new tab)

  7. Modeling and Performance Evaluation of Avalanche Detector Structures for Low Dose Medical X-ray Imaging

    … dependent detective quantum efficiency (DQE). The depth dependent MTF and noise power spectrum (NPS) are modeled by incorporating the Lubberts effect. The theoretical model also considers MTF due to K-fluorescence reabsorption. The model is then compared with experimentally determined …

    concordia Download PDF for Modeling and Performance Evaluation of Avalanche Detector Structures for Low Dose Medical X-ray Imaging (opens in a new tab)

  8. Characterization and evaluation of a photostimulable phosphor x ray imaging system.

    … (NPS), and the detective quantum efficiency (DQE). The system rms noise is photon-limited for exposures less than 1.0 mR, but has contributions from phosphor structure and quantization noise for exposures higher than 1.0 mR. The phosphor's information factor is shown to explain deviations from …

    arizona-thes Repository record for Characterization and evaluation of a photostimulable phosphor x ray imaging system. (opens in a new tab)

  9. Assessments of and Applications for High Spatio-Temporal Resolution X-Ray Detectors for Use in Medical Imaging

    … The ROD metric is the product of a detector DQE and a simulated object function, integrated over all spatial frequencies, and divided by the respective integral of another detector. This metric gives an idealized comparison of the performance of two imaging systems in detecting specific …

    buffalo Repository record for Assessments of and Applications for High Spatio-Temporal Resolution X-Ray Detectors for Use in Medical Imaging (opens in a new tab)

  10. A quantitative image evaluation study of a concurrent photon amplification treated emulsion

    … study evaluated detective quantum efficiency (DQE), modulation transfer function (MTF), and information content (IC) as a function of exposure in a comparison between normal exposure and CPA. The results showed CPA to enhance image quality relative to normal exposure at very low exposure …

    rit Repository record for A quantitative image evaluation study of a concurrent photon amplification treated emulsion (opens in a new tab)

  11. Development of a prototype CMOS digital imaging system for X-ray medical applications

    … (NPS) and the detective quantum efficiency (DQE) were estimated. Moreover, the proposed detector was compared under the same conditions to others reported previously, including a detector of wide commercial circulation. The novel detector exhibited comparable or even better performance in the …

    greece Repository record for Development of a prototype CMOS digital imaging system for X-ray medical applications (opens in a new tab)

  12. Optimization of Imaging Performance and Conspicuity in Dual-Energy X-ray Radiography

    … function (MTF), detective quantum efficiency (DQE), and noise-equivalent quanta (NEQ) - were computed using cascaded systems analysis extended to DE imaging and combined with a quantitative model of imaging task to yield estimates of detectability across a broad range of DE image acquisition …

    toronto-retro Repository record for Optimization of Imaging Performance and Conspicuity in Dual-Energy X-ray Radiography (opens in a new tab)

  13. Simulation of image formation in nuclear medicine imaging systems using Monte Carlo methods

    … in terms of the Detective Quantum Efficiency (DQE) by estimating the MTF and the Normalized Noise Power Spectrum (NNPS) of the 18F-FDG TLC plane source (1 MBq). MTFs curves were estimated from transverse reconstructed images of the plane source, whereas the NNPS data were estimated from the …

    greece Repository record for Simulation of image formation in nuclear medicine imaging systems using Monte Carlo methods (opens in a new tab)

  14. Portal Imaging Using a CSI (TL) Scintillator Coupled to a Cooled CCD Camera

    … was performed to calculate the QDE, SNR and DQE of the system. A prototype electronic portal imaging device (EPID) was built, using a 12.7 mm thick, 20.32 cm diameter, CsI (Tl) scintillator, coupled to an Astromed ® liquid nitrogen cooled CCD TV camera. The system geometry of the prototype …

    tenn-hsc Repository record for Portal Imaging Using a CSI (TL) Scintillator Coupled to a Cooled CCD Camera (opens in a new tab)

  15. Application of a High‑Resolution Computed Radiography System in Detecting an Iodinated X‑ray Contrast Agent: Small Animal Phantom Study

    … Quanta (NEQ), and Detective Quantum Efficiency (DQE). Next, dual‑energy and temporal subtraction techniques were implemented to enhance the contrast of iodinated regions and suppress soft tissue background in the phantom. The underlying physics of each technique was discussed, including the …

    tenn-hsc Repository record for Application of a High‑Resolution Computed Radiography System in Detecting an Iodinated X‑ray Contrast Agent: Small Animal Phantom Study (opens in a new tab)

  16. Design, development and characterization of a novel neutron and X-ray combined computed tomography system

    … spectrum (NPS) and detective quantum efficiency (DQE). This dissertation is a complete overview of the design of the NXCT system, operation, algorithms, performance evaluation and results"--Abstract, page iii.

    must-thes Repository record for Design, development and characterization of a novel neutron and X-ray combined computed tomography system (opens in a new tab)

  17. Monte Carlo Transport Methods for Semiconductor X-ray Imaging Detectors

    … in the ARTEMIS model, where the Swank factor and DQE have a higher dependence on the high-energy incident x rays due to increased carrier yield. Electronic noise is found to widen the pulse-height spectra and degrade the Swank factor. The effect of recombination algorithms and burst models are …

    waterloo Repository record for Monte Carlo Transport Methods for Semiconductor X-ray Imaging Detectors (opens in a new tab)

  18. Evaluation of digital X-ray detectors for medical imaging applications

    … and the resultant detective quantum efficiency (DQE). Modifications were introduced to extend the standard methods to overcome technical limitations. The performance of these detectors was compared to three commercial systems (Remote RadEye HR (CMOS APS), Hamamatsu C9732DK (CMOS PPS) and Anrad …

    greece Repository record for Evaluation of digital X-ray detectors for medical imaging applications (opens in a new tab)

  19. Investigation of optical and imaging characteristics of fluorescent screens for use in digital imaging detectors suitable for telemedicine

    … close contact with the CMOS photodiode. MTF and DQE of our CMOS sensor were found better at the whole spatial frequency range with previously published data for a passive CMOS sensor, while NNPS was comparable. The evaluated CMOS sensor is characterized by high spatial resolution and detection …

    greece Repository record for Investigation of optical and imaging characteristics of fluorescent screens for use in digital imaging detectors suitable for telemedicine (opens in a new tab)