Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"DSA system."”.

  1. Privacy and Authentication in Emerging Network Applications

    … in a centralized dynamic spectrum access (DSA) system, the spectrum resource licensees called incumbent users (IUs), have strong operational privacy requirements for the DSA service provider called spectrum access system (SAS), and hence SAS is required to perform spectrum computation …

    vt Repository record for Privacy and Authentication in Emerging Network Applications (opens in a new tab)

  2. Application of energy-based power system features for dynamic security assessment

    … of on-line Dynamic Security Assessment (DSA) to monitor, alert, and enhance system security is constrained by the longer computational cycle time. Traditional techniques requiring extensive numerical computations make it challenging to complete the assessment within an acceptable time. …

    manitoba Repository record for Application of energy-based power system features for dynamic security assessment (opens in a new tab)

  3. Spectrum sharing policy and supporting techniques for passive-active coexistence.

    … increased risk of interference to passive systems operating under static allocations in adjacent bands. Dynamic Spectrum Access (DSA) techniques offer solutions capable of coordinating spectrum and creating coexistence despite growing bandwidth needs of next-generation wireless …

    baylor Repository record for Spectrum sharing policy and supporting techniques for passive-active coexistence. (opens in a new tab) Embargoed until 2029-08-15

  4. Controller design and implementation on a two-axis dual stage nanopositioner for local circular scanning in high speed atomic force microscopy

    … pattern, a high-speed, Dual-Stage Actuator (DSA) system is a natural fit. DSAs consist of the serial combination of a (relatively) low-speed, long-range piezoelectric actuator (LRA) and a high-speed, short-range piezoelectric actuator (SRA). The SRA can be dedicated to implementing the local …

    bu Repository record for Controller design and implementation on a two-axis dual stage nanopositioner for local circular scanning in high speed atomic force microscopy (opens in a new tab)

  5. High Resolution X-ray Microscopy Using Digital Subtraction Angiography for Small Animal Functional Imaging

    … the development of a small animal x-ray imaging system capable of minimally invasive real-time, high resolution vascular visualization, and cardio-pulmonary blood flow measurements in the live animal. The x-ray technique used was digital subtraction angiography (DSA). This technique is a …

    duke Repository record for High Resolution X-ray Microscopy Using Digital Subtraction Angiography for Small Animal Functional Imaging (opens in a new tab)

  6. Toward Privacy-Preserving and Secure Dynamic Spectrum Access

    Dynamic spectrum access (DSA) technique has been widely accepted as a crucial solution to mitigate the potential spectrum scarcity problem. Spectrum sharing between the government incumbents and commercial wireless broadband operators/users is one of the key forms of DSA. Two categories of spectrum …

    vt Repository record for Toward Privacy-Preserving and Secure Dynamic Spectrum Access (opens in a new tab)

  7. Spectrum Management Issues in Centralized and Distributed Dynamic Spectrum Access

    Dynamic spectrum access (DSA) is a powerful approach to mitigate the spectrum scarcity problem caused by rapid increase in wireless communication demands. Based on architecture design, DSA systems can be categorized as centralized and distributed. To successfully enable DSA, both centralized and …

    vt Repository record for Spectrum Management Issues in Centralized and Distributed Dynamic Spectrum Access (opens in a new tab)