Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 58 for “"Dark-Field imaging"”

  1. High energy x-ray implementation of phase contrast and dark field imaging

    X-ray phase contrast and dark field imaging are emerging imaging modalities which provide significantly enhanced visibility of details classically considered “x-ray invisible” and complementary information on a sample’s micro-structure, respectively. To date they have been successfully implemented …

    ucl Repository record for High energy x-ray implementation of phase contrast and dark field imaging (opens in a new tab)

  2. Hollow cone dark field imaging: automatic acquisition, and its contrast for magnesium

    Hollow Cone Dark Field (HCDF) imaging is a powerful technique, yet it remains under-used for contrast-orientation studies—particularly when rapid, well-timed illumination adjustments are required and, up to the present time of authoring this thesis, no dedicated simulation protocols exist. The key …

    manitoba Repository record for Hollow cone dark field imaging: automatic acquisition, and its contrast for magnesium (opens in a new tab)

  3. Total internal reflection microscopy: super-resolution imaging of bacterial dynamics and dark field imaging

    … tightly linked to cell wall synthesis. TIRF-SIM imaging confirmed that MreB forms filaments which run on straight tracks. Special events like changes of tracks or reversals in direction could be observed. The transport velocity of MreB was found to depend on the filament length. The …

    freiburg-diss Repository record for Total internal reflection microscopy: super-resolution imaging of bacterial dynamics and dark field imaging (opens in a new tab)

  4. Single-shot X-ray Phase Contrast and Dark-field Imaging with a Single-mask Set-up

    Traditional X-ray imaging, which relies on attenuation contrast, faces challenges in differentiating materials with similar attenuation coefficients, particularly in soft tissues. X-ray phase contrast imaging (XPCI) and dark-field (DF) imaging address this limitation by detecting phase shifts and …

    houston Repository record for Single-shot X-ray Phase Contrast and Dark-field Imaging with a Single-mask Set-up (opens in a new tab) Embargoed until 2026-12-01

  5. Terahercinės spinduliuotės naudojimas biologinių audinių vaizdinimui /

    … to image biological tissues using bright and dark field imaging techniques. We used 0,584 THz frequency (513 μm wavelength) radiation on colon tissue samples, one of which was affected by colon adenocarcinoma. Firstly, our constructed terahertz imaging system’s spatial resolution was measured. …

    vilnius Repository record for Terahercinės spinduliuotės naudojimas biologinių audinių vaizdinimui / (opens in a new tab)

  6. Defect Insensitive Light Emission in Blue Diode Materials Investigated by Electron Microscopy and Transmission Cathodoluminescence

    … using various techniques, among them: bright field/dark field imaging, weak beam dark field imaging, high resolution transmission electron microscopy, energy dispersive x-ray spectroscopy, and high angle annular scanning transmission electron microscopy for elemental contrast (z-contrast). We …

    epfl Repository record for Defect Insensitive Light Emission in Blue Diode Materials Investigated by Electron Microscopy and Transmission Cathodoluminescence (opens in a new tab)

  7. Directional dark-field X-ray imaging of composite materials

    Dark-Field X-ray Imaging allows X-ray imaging systems to detect information about features in a sample which would otherwise be undetectably small. Scattering from these microstructures is detected rather than resolving them directly - if the features causing the scattering have some orientation, …

    soton Repository record for Directional dark-field X-ray imaging of composite materials (opens in a new tab)

  8. RubyNet: a physics-informed convolutional neural network for phase retrieval in speckle-based x-ray imaging

    Speckle-Based Imaging (SBI) enables X-ray phase-contrast and dark-field imaging with high sensitivity to weakly absorbing materials but typically requires multiple acquisitions, resulting in increased radiation dose. In this work, we introduce RubyNet, a physics-informed convolutional neural …

    uniandes Repository record for RubyNet: a physics-informed convolutional neural network for phase retrieval in speckle-based x-ray imaging (opens in a new tab)

  9. Surface plasmon based spectroelectrochemical tuning and sensing with gold nanoparticle dimers

    … gold nanoparticles. I combined hyperspectral dark field imaging, cyclic voltammetry, and single particle scattering spectroscopy in a purpose-built custom instrument to investigate the electrochemical sensitivity and tuning mechanisms of surface plasmon spectroscopy. Cyclic spectrovoltammetry …

    rice Repository record for Surface plasmon based spectroelectrochemical tuning and sensing with gold nanoparticle dimers (opens in a new tab)

  10. Structural investigation of Ge-Sb-Te thin films by aberration-corrected scanning transmission electron microscopy

    … investigation included common techniques such as dark-field imaging, selected area diffraction and secondary X-ray spectroscopy, as well as advanced techniques such as probe aberration-corrected imaging (Cs-corrected STEM) at various collection angles and scanning nano-beam diffraction. The …

    cau-kiel Repository record for Structural investigation of Ge-Sb-Te thin films by aberration-corrected scanning transmission electron microscopy (opens in a new tab)

  11. Untersuchung der Mikrozirkulation bei Neugeborenen als Möglichkeit zum Frühscreening von Infektionen

    … 1. und 3. Lebenstag einmalig mittels Sidestream Dark Field Imaging- einem Intravitalmikroskop- untersucht. Der Untersucher war hinsichtlich der klinischen Befunde der Kinder geblindet. Sidestream Dark Field Imaging kann durch die dünne keratinarme Haut des Neugeborenen die Mikrozirkulation in …

    lmu-germany Repository record for Untersuchung der Mikrozirkulation bei Neugeborenen als Möglichkeit zum Frühscreening von Infektionen (opens in a new tab)

  12. Cardiovascular risk assessment in diabetes

    … in diabetes, and its presentation with different imaging modalities. The relation between epicardial adipose tissue and plasma biomarkers with coronary atherosclerosis were investigated. Furthermore, extent and morphology of atherosclerosis are compared in patients with type 1- and type 2 …

    leiden Repository record for Cardiovascular risk assessment in diabetes (opens in a new tab)

  13. Using Electron Energy Loss Spectroscopy to investigate the structure of the mirror coatings of gravitational wave detectors

    … electron microscopy was used, specifically dark-field imaging and electron energy-loss spectroscopy (EELS). Two different techniques were used, one on each of the two coating types (tantala and silica, which have a low and high refractive index, respectively). The first technique was …

    glasgow Repository record for Using Electron Energy Loss Spectroscopy to investigate the structure of the mirror coatings of gravitational wave detectors (opens in a new tab)

  14. Image formation mechanisms in three-dimensional aberration-corrected scanning transmission electron microscopy

    … for various modes of three-dimensional imaging in aberration-corrected scanning transmission electron microscopy. Discrete tomography is used to determine and refine the three-dimensional structure of molecular nanowire bundles. The structure determination is expedited by the use of …

    oxford Repository record for Image formation mechanisms in three-dimensional aberration-corrected scanning transmission electron microscopy (opens in a new tab) Restricted access

  15. X-Ray Dark-Field Tensor Tomography : a Hitchhiker's Guide to Tomographic Reconstruction and Talbot Imaging

    X-ray dark-field imaging allows to resolve the conflict between the demand for centimeter scaled fields of view and the spatial resolution required for the characterization of fibrous materials structured on the micrometer scale. It draws on the ability of X-ray Talbot interferometers to provide …

    wurz-thes Repository record for X-Ray Dark-Field Tensor Tomography : a Hitchhiker's Guide to Tomographic Reconstruction and Talbot Imaging (opens in a new tab)

  16. Disorder and nanopatterning in ordered binary alloys: in situ ion irradiation and kinetic Monte Carlo simulation

    … through in situ electron diffraction and dark-field transmission electron microscopy. Under irradiation with 500 keV Ne+ ions, our diffraction analysis reveals a similar, but steeper, trend in disordering rate as previously reported by resistivity. Further investigations by superlattice, …

    uiuc Repository record for Disorder and nanopatterning in ordered binary alloys: in situ ion irradiation and kinetic Monte Carlo simulation (opens in a new tab)

  17. Atomic-scale and three-dimensional transmission electron microscopy of nanoparticle morphology

    The burgeoning field of nanotechnology motivates comprehensive elucidation of nanoscale materials. This thesis addresses transmission electron microscope characterisation of nanoparticle morphology, concerning specifically the crystal- lographic status of novel intermetallic GaPd2 nanocatalysts and …

    cambridge Repository record for Atomic-scale and three-dimensional transmission electron microscopy of nanoparticle morphology (opens in a new tab)

Page 1 of 3