Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 57 for “"Darkfield"”.

  1. Multi-Exposure Darkfield Digital Inline Holography for Ultrafast Microparticle Tracking

    … imaging technique named multi-exposure darkfield digital inline holography was developed to deliver 3D microparticle tracking at megahertz frequencies over an extended depth-of-field with high resolution using a single-camera setup. The proposed system integrates a low-cost nanosecond …

    umn Repository record for Multi-Exposure Darkfield Digital Inline Holography for Ultrafast Microparticle Tracking (opens in a new tab)

  2. Sensing and Imaging Biomolecules with Plasmonic Nanoparticle Assemblies Coupled with Darkfield Microscopy

    … nanostructure, which can be readily captured by darkfield microscopy. The detection limit, dynamic range, and sensitivity can be tuned by controlling the size of the assembly. We found that the aptamer-linked nanoparticle assemblies were selective to only ATP, and not other adenine-containing …

    york Repository record for Sensing and Imaging Biomolecules with Plasmonic Nanoparticle Assemblies Coupled with Darkfield Microscopy (opens in a new tab)

  3. Imaging of plasmonic nanoparticles for biomedical applications

    … have been used in this project are hyperspectral darkfield microscopy and spatial modulation microscopy.<br/><br/>Hyperspectral darkfield microscopy is a darkfield technique in which a supercontinuum light source and an acousto-optic tuneable filter are used to collect darkfield images which …

    soton Download PDF for Imaging of plasmonic nanoparticles for biomedical applications (opens in a new tab)

  4. Novel Electroanalytical Tools for Probing Electrochemically Generated Surface Nanobubble Characteristics

    … 4 describes the development of off-axis darkfield microscopy for imaging a single nanobubble at a carbon nanoelectrode. This innovative imaging platform permits correlated electrochemical and optical detection for new insights into nanobubble characteristics previously inaccessible from …

    washington Repository record for Novel Electroanalytical Tools for Probing Electrochemically Generated Surface Nanobubble Characteristics (opens in a new tab)

  5. Electric Field Manipulation of Gold Nanorods: Characterization of Far-Field Alignment and Spatial Positioning Through Optical Response Imaging Techniques

    … transport micron length gold nanowires by using darkfield optical microscopy to track position. Other studies have characterized the alignment of nanometer length gold nanorods by observing changes in the absorbance spectrum. A remaining challenge is to develop methods to quantify successful …

    south-carolina Repository record for Electric Field Manipulation of Gold Nanorods: Characterization of Far-Field Alignment and Spatial Positioning Through Optical Response Imaging Techniques (opens in a new tab)

  6. Advances in optical trapping beyond biophysics: combining force and optical spectroscopies under diverse chemical conditions

    … and organic conditions using a custom OT and darkfield instrument which can uniquely measure force and scattering spectra of single gold nanoparticles (Au NPs) simultaneously. Our work reveals that standard models of trapping developed for aqueous conditions cannot account for the trends …

    bu Repository record for Advances in optical trapping beyond biophysics: combining force and optical spectroscopies under diverse chemical conditions (opens in a new tab)

  7. Fabrication, Analysis, Simulation, and Application of the Nanohole Array Sensor

    … thickness are used to block the nanoholes; and darkfield imaging system is used to obtain the images by the CCD and spectra by the spectrometer. The images and spectra of the nanoholes blocked by the individual nanospheres are analyzed and compared with those of the nanoholes before blocking. …

    houston Repository record for Fabrication, Analysis, Simulation, and Application of the Nanohole Array Sensor (opens in a new tab)

  8. Plasmonic biosensors: dark-field optical microscopy as a tool to detect cytokines

    … was immobilized on a surface and studies under darkfield microscopy. Since single 67 nm cores show different colour values than core-satellite assemblies, the colorimetric code was able to detect the antigen. In the next chapter a surface-based biosensor was proposed to improve sensitivity and …

    unsw Repository record for Plasmonic biosensors: dark-field optical microscopy as a tool to detect cytokines (opens in a new tab)

  9. Transitions: The Search for Maize Phytoliths in Spanish Teeth

    … are placed on slides and analyzed under a darkfield microscope (400 - 1600X). Potential phytoliths are then photographed and compared to enlarged images of known phytoliths.

    unr Repository record for Transitions: The Search for Maize Phytoliths in Spanish Teeth (opens in a new tab)

  10. Cinemicrography of selected parasites of fishes and of free-living stages of Haemonchus contortus

    … employing the techniques of brightfield, darkfield, phase contrast and Nomarski interference microscopy. The films are available from the Parasitology Laboratory of the Department of Zoology at Brigham Young University.

    byu Repository record for Cinemicrography of selected parasites of fishes and of free-living stages of Haemonchus contortus (opens in a new tab) Download PDF for Cinemicrography of selected parasites of fishes and of free-living stages of Haemonchus contortus (opens in a new tab)

  11. IMPROVED LED ARRAY REFLECTANCE IMAGING FOR HIGH THROUGHPUT APPLICATIONS

    … illumination patterns to capture high-quality darkfield and differential phase contrast images. However, its acquisition speed and signal to noise ratio are limited by the low backscattering of light off the surface of the specimen. The aim of this study is to enhance light delivery to the …

    jhu Repository record for IMPROVED LED ARRAY REFLECTANCE IMAGING FOR HIGH THROUGHPUT APPLICATIONS (opens in a new tab)

  12. Regression Analysis of Fracture Toughness for Secondary Osteons Located in Human Cortical Bone

    … of lightfield osteons, average diameter of darkfield osteons and average diameter of alternating osteons. This model explains the parameters that most affect fracture toughness by using a regression analysis, which also provides a regression equation to show exactly how much each specific …

    calpoly Repository record for Regression Analysis of Fracture Toughness for Secondary Osteons Located in Human Cortical Bone (opens in a new tab)

  13. A Leptospirosis Survey of Small Mammals in Brookings County, South Dakota

    … used were the microscopic agglutination test and darkfield examination of urine for spirochetes. From 32 sites, a total of 248 animals were collected from which 73 (29.4%) serum samples and 82 (33.1%) urine samples were obtained. Spirochetes were observed in the urine of 3 deer mice (Peromyscus …

    sdstate Repository record for A Leptospirosis Survey of Small Mammals in Brookings County, South Dakota (opens in a new tab)

  14. Optical Manipulation of Nanoparticles’ Flow through Porous Membranes

    … in presence of a converging laser beam in darkfield microscopy setup. The general trend in the experimental results has been postulated by analytical solutions and simulations.

    chalmers Repository record for Optical Manipulation of Nanoparticles’ Flow through Porous Membranes (opens in a new tab)

  15. Biological nanofibers in a standing wave optical trap

    … time observation of microtubule bundles using darkfield microscopy is achieved and used to characterize the trapping efficiency. Bundles of three microtubules were held in focus over a time period of hours using a trapping power of only 6mW. The suitable conditioning of the sample chamber with …

    texas Repository record for Biological nanofibers in a standing wave optical trap (opens in a new tab) Restricted access

  16. The Microcirculation in Trauma and Sepsis

    … major abdominal surgery, using Sidestream Darkfield-imaging (SDF) in relation to outcome. Skeletal muscle trauma caused PV-loss, increase in permeability and cytokine release and PGI2-treatment attenuated these changes. Sepsis led to a breakdown of the negatively charged glycocalix, which …

    lund Repository record for The Microcirculation in Trauma and Sepsis (opens in a new tab) Download PDF for The Microcirculation in Trauma and Sepsis (opens in a new tab)

  17. Characterization and synthesis of nanoscale materials

    … and a cylindrical support. Using digital darkfield techniques, this investigation can be automated. Thirdly, the structure relationship between catalyst particles and zinc oxide nanowires has been investigated using scanning and high resolution scanning transmission electron microscopes. A …

    must-thes Repository record for Characterization and synthesis of nanoscale materials (opens in a new tab)

  18. Quantification of the glycocalyx in the study of pre-eclampsia

    … glycocalyx was measured using sidestream darkfield (SDF) imaging with GlycoCheckTM. Placental tissue was collected following delivery and processed for both light and electron microscopy. Methodologies were developed to image and quantify the glycocalyx at the maternal-fetal interface …

    bristol Repository record for Quantification of the glycocalyx in the study of pre-eclampsia (opens in a new tab) Download PDF for Quantification of the glycocalyx in the study of pre-eclampsia (opens in a new tab)

Page 1 of 3