Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 36 for “"Data Center Power"”

  1. Performance-aware site-wide data center power management

    Top high performance computing (HPC) data centers recently entered the era of exascale computing, requiring up to tens of megawatts for a computing facility to meet its users’ computing needs. The massive capacity for power at a single site comes with challenges in power management. Poorly managed …

    bu Repository record for Performance-aware site-wide data center power management (opens in a new tab)

  2. High Voltage Point of Load Converter for Data Center Power Supplies

    … information storage, the energy requirement of data centers where a large number of computer systems are housed keeps increasing. However, most of the data centers today are operated inefficiently, both economically and environmentally. Efforts including improving power delivery architecture, …

    utk-theses Repository record for High Voltage Point of Load Converter for Data Center Power Supplies (opens in a new tab)

  3. COORDINATING LIQUID AND FREE AIR COOLING WITH WORKLOAD ALLOCATION FOR DATA CENTER POWER MINIMIZATION

    Data centers are seeking more efficient cooling techniques to reduce their operating expenses, because cooling can account for 30-40\% of the power consumption of a data center. Recently, liquid cooling has emerged as a promising alternative to traditional air cooling, because it can help eliminate …

    ohiolink Repository record for COORDINATING LIQUID AND FREE AIR COOLING WITH WORKLOAD ALLOCATION FOR DATA CENTER POWER MINIMIZATION (opens in a new tab)

  4. Data Center Power System Emulation and GaN-Based High-Efficiency Rectifier with Reactive Power Regulation

    <p>Data centers are indispensable for today's computing and networking society, which has a considerable power consumption and significant impact on power system. Meanwhile, the average energy usage efficiency of data centers is still not high, leading to significant power loss and system cost.</p> …

    utk-theses Repository record for Data Center Power System Emulation and GaN-Based High-Efficiency Rectifier with Reactive Power Regulation (opens in a new tab)

  5. Heterogeneous computing environment characterization and thermal-aware scheduling strategies to optimize data center power consumption

    … the heuristics and these measures is shown. The power consumption of data centers has been increasing at a rapid rate over the past few years. Motivated by the need to reduce the power consumption of data centers, many researchers have been investigating methods to increase the energy efficiency …

    colostate Repository record for Heterogeneous computing environment characterization and thermal-aware scheduling strategies to optimize data center power consumption (opens in a new tab)

  6. High-Efficiency Dual Active Bridge Converter With Stacked Secondary Phase For Next-Generation AI Data Center Power Delivery

    The rapid electrification of hyperscale AI data centers is accelerating a shift from legacy 48 V distribution ladders to ±400 V high-voltage DC backbones, concentrating residual loss and dynamic stress on a single isolated bidirectional interface. This work presents a high-density Dual Active …

    ucf Repository record for High-Efficiency Dual Active Bridge Converter With Stacked Secondary Phase For Next-Generation AI Data Center Power Delivery (opens in a new tab)

  7. Coordinating Data Center Network and Servers for Power Savings

    Data center power optimization has recently received a great deal of research attention. For example, server consolidation has been demonstrated as one of the most effective energy saving methodologies. Likewise, traffic consolidation has also been recently proposed to save energy for data center …

    ohiolink Repository record for Coordinating Data Center Network and Servers for Power Savings (opens in a new tab)

  8. All-SiC Three-Phase Converters for High Efficiency Applications

    … efficiency of three-phase converters using SiC power devices.The methodology to design a high efficiency all-SiC three-phase converter is presented. Four aspects are included: SiC power device evaluation, power loop parasitics analysis, high efficiency current source rectifier, and paralleled …

    utk-theses Repository record for All-SiC Three-Phase Converters for High Efficiency Applications (opens in a new tab)

  9. Towards Safe Power Oversubscription and Energy Efficiency of Data Centers

    Data centers contribute to approximately 1% of the global electricity consumption, and billions of dollars are spent annually worldwide in construction of new data centers to meet the rising demand for cloud-based services. Given the high cost of construction, the power infrastructure in a data …

    usf Repository record for Towards Safe Power Oversubscription and Energy Efficiency of Data Centers (opens in a new tab)

  10. Modeling, control and development of GaN power supplies for data center applications

    In recent years , data centers have become a major electric load. The efficiency and power density of power supplies in data centers have increasingly drawn attention. As a result, a two-stage power supply solution is widely used: a power factor correction (PFC) rectifier is used to build the 400V …

    texas Repository record for Modeling, control and development of GaN power supplies for data center applications (opens in a new tab)

  11. TIME AWARE VIRTUAL MACHINE PLACEMENT AND ROUTING FOR POWER EFFICIENCY IN DATA CENTERS

    … the acceptance rate while consuming as low power as possible. We first study the problem for flow-based time-aware requests, requiring a server-pair and an associated path for a specified duration. Second, we investigate how to exploit the VM-migration feature to save power. Third, we study …

    nus Repository record for TIME AWARE VIRTUAL MACHINE PLACEMENT AND ROUTING FOR POWER EFFICIENCY IN DATA CENTERS (opens in a new tab)

  12. Real-Time Wireless Sensor-Actuator Networks for Cyber-Physical Systems

    … as process control, smart manufacturing, and data center management. Sensing and control in these systems need to meet stringent real-time performance requirements on communication latency in challenging environments. There have been limited results on real-time scheduling theory for wireless …

    wustl Repository record for Real-Time Wireless Sensor-Actuator Networks for Cyber-Physical Systems (opens in a new tab)

  13. Dynamic thermal response of the data center to cooling loss during facility power failure

    Provisioning for power failure is an important element of data center design. It is important to assess both tangible and intangible costs of unplanned data center downtime. These costs must be compared with the capital cost of providing various levels of backup power infrastructure to compute and …

    gatech Repository record for Dynamic thermal response of the data center to cooling loss during facility power failure (opens in a new tab)

  14. Real-Time Control Over Wireless Networks

    … farming, smart manufac- turing, smart grid, and data center power management. These applications require the wireless stack to provide a scalable, reliable, low-power and low-latency communication. To realize a predictable and reliable communication in a highly unreliable wireless environment, …

    wayne-thes Repository record for Real-Time Control Over Wireless Networks (opens in a new tab)

  15. The Zero Inductor-Voltage Converter

    Data centers and servers are one of the largest growing consumers of electrical power in the world today. In data center power distribution, the majority of the loss still occurs in the final conversion stages at the server rack, and server board level. A 48-volt architecture has been proposed, and …

    queens Repository record for The Zero Inductor-Voltage Converter (opens in a new tab)

  16. Reducing Peak Power Consumption in Data Centers

    Data centers are assets of high value in the enterprise, but are currently being devalued because their actual lifetimes are falling well short of their predicted lifetimes, due to the rapid growth of peak power consumption, which enterprises have not been able to control effectively. In order to …

    ohiolink Repository record for Reducing Peak Power Consumption in Data Centers (opens in a new tab)

  17. Feedback-Directed Management of Performance and Power for Emerging Computer Systems

    … management challenge of both performance and power simultaneously. For example, distributed real-time embedded systems such as cyber-physical systems need to reduce power consumption while enforces CPU utilization bounds on multiple uniprocessors in order to meet end-to-end deadlines. Data …

    utk-theses Repository record for Feedback-Directed Management of Performance and Power for Emerging Computer Systems (opens in a new tab)

  18. Two-Stage-Membraneless Electrochemically Mediated Amine Regeneration for Carbon Capture and Direct Air Capture

    … energy-intensive applications such as AI data center power systems. This work addresses these limitations through the development and integration of electrochemically mediated amine regeneration (EMAR) systems, focusing on advancing absorbent chemistry, process architecture, and …

    houston Repository record for Two-Stage-Membraneless Electrochemically Mediated Amine Regeneration for Carbon Capture and Direct Air Capture (opens in a new tab) Embargoed until 2028-05-01

  19. LLC Resonant Converters for Energy Efficient Power Electronics Systems

    With modern power electronic systems advancing towards higher efficiency, smaller size, lighter weight, and lower noise, Switch-Mode Power Supplies (SMPSs) based on resonant converters have garnered widespread attention. Among various resonant converters, LLC resonant converters are extensively …

    queens Repository record for LLC Resonant Converters for Energy Efficient Power Electronics Systems (opens in a new tab)

Page 1 of 2