Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"Data Concentrator"”.

  1. The Virginia Tech Phasor Data Concentrator Analysis & Testing System

    … PMUs over their respective power systems, Phasor Data Concentrators (PDCs) play a crucial part in accurately relaying data from the point of measurement to the operators at the control center. The current Synchrophasor standard, IEEE C37.118-2005 covers adequately the steady state characterization …

    vt Repository record for The Virginia Tech Phasor Data Concentrator Analysis & Testing System (opens in a new tab)

  2. PPP - Ethernet gateway RS232 - RJ45 network adapter for an Echelon “Data Concentrator”

    … också vara så att kunden inte vill betala för datatrafiken som modemen genererar. En nuvarande kund vill t.ex. att man ska leverera mätvärden över deras interna trådlösa WiMAX nät. Denna uppsats kommer att undersöka vilka olika lösningar det finns för att få en multipunkt att använda ett …

    chalmers Repository record for PPP - Ethernet gateway RS232 - RJ45 network adapter for an Echelon “Data Concentrator” (opens in a new tab)

  3. Detection Techniques for Data-Level Spoofing in GPS-Based Phasor Measurement Units

    … and uploads the phasor information to the Phasor Data Concentrator (PDC) at a rate of 30 to 60 observations per second. Typically, PMUs utilize a Global Positioning System (GPS) reference source to provide the required synchronization across wide geographical areas. On the other hand, civil GPS …

    concordia Download PDF for Detection Techniques for Data-Level Spoofing in GPS-Based Phasor Measurement Units (opens in a new tab)

  4. Open-Source Testbed to Evaluate the Cybersecurity of Phasor Measurement Units

    The Phasor Measurement Unit provides clear data for ease of grid visibility. A major component of the device is the Global Positioning System (GPS) for time synchronization across the board. However, this device has become more susceptible to cyber-attacks such as spoofing. This paper constructs an …

    vt Repository record for Open-Source Testbed to Evaluate the Cybersecurity of Phasor Measurement Units (opens in a new tab)

  5. Development of a laboratory synchrophasor network and an application to estimate transmission line parameters in real time

    … supplied from a common GPS clock. The real time data collected from PMUs are sent to a phasor data concentrator (PDC) through Ethernet using the TCP/IP protocol. A real-time transmission line parameter monitoring application program that uses the synchrophasor data provided by the PDC is …

    manitoba Repository record for Development of a laboratory synchrophasor network and an application to estimate transmission line parameters in real time (opens in a new tab)

  6. Practical Implementation of a Security-Dependability Adaptive Voting Scheme Using Decision Trees

    … reporting positive sequence currents to a Phasor Data Concentrator (PDC). At the PDC, the state of the power system is defined as Stressed or Safe and a set of relays either vote or perform normal operation, respectively. The Adaptive Voting Scheme was implemented using two configurations: …

    vt Repository record for Practical Implementation of a Security-Dependability Adaptive Voting Scheme Using Decision Trees (opens in a new tab)

  7. Design of secure and stable power system integrated with renewable energy sources

    … Phasor Measurement Units (PMUs) and Phasor Data Concentrator (PDCs) will allow us to collect system level information in real time. In future electrical power systems, the wide use of PMUs is inevitable and thus raises the importance of cyber security. Conventional model-based methodologies …

    ttu Repository record for Design of secure and stable power system integrated with renewable energy sources (opens in a new tab)

  8. Experimental set up of PMU network and application of artificial neural network for PMU generated data analysis

    … (WAM). The high resolution of time-stamped data containing 30 to 60 samples per second provides high accuracy for power grid monitoring. The introduction of PMUs in the power system has increased the large volume of data. These data like the voltage, current, frequency, and phase angle …

    ttu Repository record for Experimental set up of PMU network and application of artificial neural network for PMU generated data analysis (opens in a new tab)

  9. Power communications over the last kilometre

    … as microprocessors the need to transmit more data to and from such premises became urgent. <br></br><br></br>The last kilometre problem of getting information to and from the customer’s premises to the node or data concentrator for connection to the available services, such as the internet, …

    the-open-u Download PDF for Power communications over the last kilometre (opens in a new tab)

  10. Applications of PMUSimulator in PDC Testing

    … system, phasor measurement units and phasor data concentrators are essential for real time control of the system. PMUs are time synchronized throughout the power system and take sample measurements in very small windows of time. Phasor Data Concentrators accept PMU data and time align the …

    vt Repository record for Applications of PMUSimulator in PDC Testing (opens in a new tab)

  11. On The Security of Wide Area Measurement System and Phasor Data Collection

    … from different PMUs are transferred through a data network and collected at one or multiple data concentrators. The timely collection of phasors from PMU dispersed across the grid allows to maintain system observability and take corrective actions when needed. This collection is made possible …

    concordia Download PDF for On The Security of Wide Area Measurement System and Phasor Data Collection (opens in a new tab)

  12. Evaluation and Standardizing of Phasor Data Concentrators

    … estimation to analyzing blackout causes. Phasor Data Concentrators (PDC) collect and process PMU data. As such, it is important that PMU and PDC communication is seamless. PDCs are set up at multiple utilities and power authorities and also need to be able to communicate and send data to one …

    vt Repository record for Evaluation and Standardizing of Phasor Data Concentrators (opens in a new tab)

  13. Implementation of the Security-Dependability Adaptive Voting Scheme

    As the world moves further into the 21st century, the electricity demand worldwide continues to rapidly grow. The power systems that supply this growing demand continue to be pushed closer to their limits. When those limits are exceeded, system blackouts occur that have massive societal and …

    vt Repository record for Implementation of the Security-Dependability Adaptive Voting Scheme (opens in a new tab)

  14. Datový koncentrátor ve VHDL

    V textu bakalářské práce jsou shrnuty základy jazyka VHDL, popsáno vývojové prostředí ISE Webpack. Dále je popsán způsob komunikace a vlastnosti sériové linky. A také vlastnosti standardu Ethernet a způsob komunikace přes rozhraní MII. V další části je stručně představen hardware použitý pro návrh …

    brno-tech Repository record for Datový koncentrátor ve VHDL (opens in a new tab)

  15. Demonstrační úloha zaměřující se na problematiku Smart Metering

    Diplomová práce se zabývá technologií PLC a problematikou Smart Metering. Teoretická část popisuje princip funkčnosti technologie, její výhody a nevýhody. V experimentální části této práce byla navržena metodika testování pro koncentrátor a elektroměry. Dále byla realizována rozsáhlá sada …

    brno-tech Repository record for Demonstrační úloha zaměřující se na problematiku Smart Metering (opens in a new tab)

  16. Data koncentrátor pro chytré sítě

    Cílem práce je návrh Data koncentrátoru pro inteligentní sítě (Smart Grids). Data koncentrátor stanoví rozhraní mezi serverovými systémy distribučních společností a koncovými zařízeními, které představují elektroměry, vodoměry, plynoměry a další zařízení. V práci byl vytvořen návrh hardwarového i …

    brno-tech Repository record for Data koncentrátor pro chytré sítě (opens in a new tab)

  17. Datový koncentrátor

    Tato diplomová práce se zabývá návrhem a realizací modulárního Datového koncentrátoru pro nejrůznější typy měření v různorodých podmínkách. V práci je popsána koncepce zařízení, dále jeho základní principy, postup jeho návrhu a jeho funkčnost. Taktéž je zde popsán navržený lightweight protokol pro …

    brno-tech Repository record for Datový koncentrátor (opens in a new tab)