Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 29 for “"Daylight Factor"”.

  1. Daylight in Existing Buildings - A Comparative Study of Calculated Indicators for Daylight

    Daylight is an important part when designing a building. It is vital to have a good level of daylight in rooms where people stay for extended periods of time since it has been proven that a lack of daylight affects people’s health and wellbeing in a negative way. Daylight in building is getting …

    chalmers Repository record for Daylight in Existing Buildings - A Comparative Study of Calculated Indicators for Daylight (opens in a new tab)

  2. Daylight and planning in Europe

    This work addresses issues related to daylight in urban canyons in predominantly sunny climates. Reflected sunlight from obstructions and ground is a major contribution to the illumination of buildings in orientations and at times when the sun is behind the building. Physical measurements collected …

    london-metro Download PDF for Daylight and planning in Europe (opens in a new tab)

  3. Prediction of interior daylight under clear sky conditions.

    Most available techniques for predicting internal daylight illuminance do not take into account reflected sunlight, nor the fact that under clear sky conditions the direction of the illuminance is usually upwards, not downwards from the sky. The general goal of this study is to investigate the …

    whiterose Download PDF for Prediction of interior daylight under clear sky conditions. (opens in a new tab)

  4. THE PERFORMANCE OF A DYNAMIC THERMALLY-ADAPTIVE CURVING LIGHT SHELF SYSTEM: AN EXPERIMENTAL INVESTIGATION FOR OPTIMIZING NATURAL-LIGHT DISTRIBUTION IN BUILDINGS

    … redirecting angles which help to maximize daylight penetration deeper into the interior space of a building resulting in lower electrical lighting usage. The study consists of a series of computer-assisted ray-tracing studies, and physical experimental scale models. The results of a …

    ku Repository record for THE PERFORMANCE OF A DYNAMIC THERMALLY-ADAPTIVE CURVING LIGHT SHELF SYSTEM: AN EXPERIMENTAL INVESTIGATION FOR OPTIMIZING NATURAL-LIGHT DISTRIBUTION IN BUILDINGS (opens in a new tab)

  5. Effect of Daylighting on Energy Consumption and Daylight Quality in an Existing Elementary School

    This research investigates the effects of daylighting in an existing elementary school in College Station, Texas. The conclusions are generalizable to similar school designs in hot and humid climates. This study focuses on the trends observed in the building??s heating, cooling, and lighting energy …

    tamu Repository record for Effect of Daylighting on Energy Consumption and Daylight Quality in an Existing Elementary School (opens in a new tab)

  6. Comparison of energy consumption with regard to type and percentage of glazing, location and orientation in classroom spaces

    Much of the art of daylighting lies in the judicious placement of windows in relation to the interior, in order to achieve the desired levels of illumination and view. Studies have shown that the glazing size, location and type all impact the internal energy loads. Schools are incorporating …

    vt Repository record for Comparison of energy consumption with regard to type and percentage of glazing, location and orientation in classroom spaces (opens in a new tab)

  7. Balancing Human Visual Comfort and Psychological Wellbeing in Private Offices

    … the study assists the quality and quantity of daylighting distribution across the space based on accepted lighting standards, norms or guidelines. Mathematically, it was proven that objective DGI values can be used with Ev levels in order to prescribe feasible user visual comfort and better …

    uiuc Repository record for Balancing Human Visual Comfort and Psychological Wellbeing in Private Offices (opens in a new tab)

  8. Accessible Lighting in the Workplace: Reducing the Negative Impact of Photosensitivity and Migraines

    … Physical analysis includes illuminance values, daylight factor plans, and HDR images from data collected on September 22nd, 2020 and March 22nd-23rd, 2021. The spaces selected are disparate examples of workplaces that are occupied around the clock. A survey was conducted from April 1st-30th, …

    oregon Repository record for Accessible Lighting in the Workplace: Reducing the Negative Impact of Photosensitivity and Migraines (opens in a new tab)

  9. Impact of Façade Glazing on Energy Demand & Indoor Environment Quality Process for early glazing design of office buildings

    … demand, as well the impact on PPD value and daylight factor in an office building in Malmö, Oslo and Reykjavik. The office building is portrayed by a study case designed according to the Norwegian passive house standard NS 3701. Hence, the results are only applicable based on this study case. …

    chalmers Repository record for Impact of Façade Glazing on Energy Demand & Indoor Environment Quality Process for early glazing design of office buildings (opens in a new tab)

  10. Iluminação natural como fator de qualidade : uma abordagem perceptiva em três habitações de interesse social contemporâneas na cidade de São Paulo/SP/Brasil

    … de iluminância e posteriormente o cálculo do Daylight Factor (Fator de Luz do dia) dos ambientes e aplicados questionários de avaliação de percepção da atmosfera e qualidade da iluminação. Os questionários foram desenvolvidos com base nas metodologias Atmosphere Metrics (Vogels, 2008) e ELI - …

    brazil-ufrgs Repository record for Iluminação natural como fator de qualidade : uma abordagem perceptiva em três habitações de interesse social contemporâneas na cidade de São Paulo/SP/Brasil (opens in a new tab)

  11. Thermal and lighting performance of toplighting systems in the hot and humid climate of Thailand

    … lighting performance parameters examined were daylight factor, illuminance level, light distribution, and uniformity. EnergyPlus was used as the thermal analysis tool, and RADIANCE, along with a physical scale model, was used as the lighting performance analysis tool. The sky conditions tested …

    tamu Repository record for Thermal and lighting performance of toplighting systems in the hot and humid climate of Thailand (opens in a new tab)

  12. Daylighting of Buildings

    … ukazatele použity činitel denní osvětlenosti (Daylight Factor, DF) a rovnoměrnost osvětlení, které slouží k systematickému hodnocení jak úrovně denního osvětlení, tak jeho prostorového rozložení v jednotlivých funkčních místnostech. Výsledky analýzy ukazují, že klíčovými faktory ovlivňujícími …

    brno-tech Repository record for Daylighting of Buildings (opens in a new tab)

  13. Assessing the daylight transmittance of atria roofs in real buildings.

    The displacement of artificial lighting with daylighting in buildings has been shown to reduce energy consumption and provide preferable spaces for building occupants. The atrium is one means of achieving daylighting objectives in medium to large scale buildings. The transmittance of daylight …

    sheffield-hallam Download PDF for Assessing the daylight transmittance of atria roofs in real buildings. (opens in a new tab)

  14. Indoor Natural Light Performance of Clerestory Mounted Dynamic Thermally Adaptive Light Louvers

    … efficiency and environmentally friendly design, daylighting has become an important design factor. This thesis examines the effectiveness of passive daylight systems using thermally adaptive materials that interact with outdoor ambient temperatures. Existing literature has demonstrated the …

    ku Repository record for Indoor Natural Light Performance of Clerestory Mounted Dynamic Thermally Adaptive Light Louvers (opens in a new tab)

  15. Optimizing daylight and aesthetics in energy renovations; a parametric approach to Swedish multifamily housing

    … buildings can be designed to enhance interior daylight quality, thermal comfort, and architectural value, while still meeting upcoming regulatory demands. With the new EU EPBD and the revised Swedish building regulations in BBR coming into force, a large portion of the existing residential …

    chalmers Repository record for Optimizing daylight and aesthetics in energy renovations; a parametric approach to Swedish multifamily housing (opens in a new tab)

  16. Evaluation of Sun- and Daylight Availability in Early Stages of Design Development - A Method Based on Correlations of Interior and Exterior Metrics

    … Simulations with regard to solar heat gains and daylight calculations are incorporated into the design later on, leading to design issues which could be impossible to solve. The purpose of this Master’s thesis is therefore to develop a methodology that with simple 3D models and input data can …

    chalmers Repository record for Evaluation of Sun- and Daylight Availability in Early Stages of Design Development - A Method Based on Correlations of Interior and Exterior Metrics (opens in a new tab)

  17. Daylighting in atrium spaces

    … atria perform, this research has focused only on daylighting. The thesis has been presented in two parts. The first part provides the background information, the extent of daylighting research in atria, objective and scope of the research. The environmental role of atria has also been discussed. …

    ubc Repository record for Daylighting in atrium spaces (opens in a new tab) Download PDF for Daylighting in atrium spaces (opens in a new tab)

  18. Study of the relationship between indoor daylight environments and patient average length of stay (ALOS) in healthcare facilities

    This study investigates how indoor daylight environments affect patient Average Length of Stay (ALOS), by evaluating and analyzing daylight levels in patient rooms in comparison to their ALOS. The patient ALOS data were taken at one general hospital in Inchon, Korea and the other in Bryan, Texas, …

    tamu Repository record for Study of the relationship between indoor daylight environments and patient average length of stay (ALOS) in healthcare facilities (opens in a new tab)

Page 1 of 2