A Stark decelerator on a chip
A lithographically-etched chip containing 1254 microscopic electrodes at a center-to-center spacing of 40 micron is used to produce an array of electric field strength minima 25 micron above the surface with a spacing between neighboring minima of 120 micron. These minima are produced by applying a …
-
Structural impacts of inflatable aerodynamic decelerator design
… to land larger payloads to Mars, more capable decelerators are required to advance beyond the performance limitations of traditional heritage entry, descent, and landing technologies. One potential technology is an inflatable aerodynamic decelerator (IAD), a flexible aeroshell that can be …
-
Morphing Hypersonic Inflatable Aerodynamic Decelerator (HIAD) Mechanisms and Controls
… vehicles. A Hypersonic Inflatable Aerodynamic Decelerator (HIAD) is an emerging technology that provides an increased drag area by inflating the aeroshell to diameters not possible with rigid aeroshells, allowing the vehicle to decelerate higher in the atmosphere, offering access to higher …
-
A Multistage Zeeman Decelerator for Molecular-Beam Scattering Experiments
Contains fulltext : 204153.pdf (Publisher’s version ) (Open Access)
-
Aerodynamic design, analysis, and validation of a supersonic inflatable decelerator
… is the supersonic inflatable aerodynamic decelerator (IAD). This dissertation presents an overview of work performed in maturing a particular type of IAD, the tension cone. The tension cone concept consists of a flexible shell of revolution that is shaped so as to remain under tension and …
-
High-resolution imaging of molecular collisions using a Zeeman decelerator
In this doctoral research a Zeeman decelerator was employed to obtain precise control over magnetic particles and prepare them for cold and controlled molecular collision experiments in a crossed-beam setup. Combined with an improved velocity map imaging apparatus and novel recoil-free ionization …
-
Comprehensive Study and Optimized Redesign of the CERN's Antiproton Decelerator Target
El Antiproton Decelerator Target (AD-Target) es un dispositivo único responsable de la generación de Antiprotones en la Organización Europea para la Investigación Nuclear (CERN). En operación, intensos haces de protones con una energía de 26 GeV son impactados en su núcleo, un cilindro de 3 mm de …
-
Beam position monitoring in the clic drive beam decelerator using stripline technology
… beam position monitoring system for the CLIC DB decelerator needs to meet the following requirements: - It should be as simple and economic as possible, as 41580 units are required, amounting to 75% of all CLIC BPMs. - The signal processing scheme should not be a ffected by the PETS interference. …
-
Flight test of a supersonic decelerator on Earth to simulate a Mars entry
… is presented for simulation of the descent of a decelerator (parachute) and spacecraft for entry through the atmosphere of the planet Mars by a flight test in the Earth's atmosphere. Engineering atmosphere models for Mars are defined and based on these models requirements for parachutes to be …
-
An Aeroelastic Evaluation of the Flexible Thermal Protection System for an Inflatable Aerodynamic Decelerator
… for the NASA Hypersonic Inflatable Aerodynamic Decelerator (HIAD). A flat, square FTPS coupon exhibits violent oscillations during experimental aerothermal testing in NASA's 8 Foot High Temperature Tunnel, leading to catastrophic failure. The behavior of the structural response suggested that …
-
Uncertainty quantification applied to the analysis and design of a hypersonic inflatable aerodynamic decelerator for spacecraft reentry
… analysis of a Hypersonic Inflatable Aerodynamic Decelerator configuration for Mars entry, subject to uncertainty sources in the high-fidelity computational models and the operating conditions. Efficient uncertainty quantification methods based on stochastic expansions are applied to the analysis …
-
Towards the study of cold chemical reactions using Zeeman decelerated supersonic beams
… beam setup including a 12-stage Zeeman decelerator. The Zeeman decelerator follows an original design that makes it possible to replace individual deceleration coils. Using ground-state hydrogen atoms as a test system, it is shown that the transverse acceptance in a Zeeman decelerator …
-
Manipulation of the motion of polyatomic molecules by AC and DC Stark deceleration
A conventional DC Stark decelerator, consisting of 180 stages, was constructed and tested. The experimental setup was characterized using ammonia (NH₃) as the reference molecule. Resonance Enhanced Multi-Photon Ionization method (REMPI) was used to detect the ammonia molecules. Deceleration of …
-
Dynamic inflow model for autorotation
… conducted by dropping an autorotative decelerator show a transient increase in rotor thrust leading to a steady-state terminal descent speed. An articulated dual-hinge mechanism consisting of folding and δ₃ hinges in tandem allows large flap displacements of the blades. This behavior is …
-
Formation and manipulation of diatomic radicals
… the development and application of a Zeeman decelerator for manipulating paramagnetic molecular species in supersonic beams. The primary goal of this work is to enable precise control over the velocity and internal quantum states of reactive radicals—specifically hydroxyl (OH) and cyanogen …
-
Zeeman deceleration of methyl radical
Conventional Zeeman decelerator, consisting of 80 stages, was constructed and tested. The experimental setup was characterized using O₂ as the reference molecule. Known results of deceleration of O₂ were reproduced. As an extension, detailed REMPI analysis of deceleration of O₂ was carried out, …
-
Stark deceleration and reactivity of polyatomic molecules and ions at low temperatures
… been achieved through the combination of a Stark decelerator for neutral dipolar molecules, and a linear Paul ion trap.</p> <p>The Stark deceleration process for ND<sub>3</sub> was examined in detail, through the analysis of experimental data in combination with newly written molecular dynamics …
-
Stark deceleration and reactivity of polyatomic molecules and ions at low temperatures
… been achieved through the combination of a Stark decelerator for neutral dipolar molecules, and a linear Paul ion trap.</p> <p>The Stark deceleration process for ND<sub>3</sub> was examined in detail, through the analysis of experimental data in combination with newly written molecular dynamics …
-
Alternating-gradient focusing and deceleration of large molecules
… quantum state using an alternating-gradient decelerator, a new high voltage switching scheme has to be applied in order to achieve phase stability for the decelerated packets. In addition, the coupling of transverse and longitudinal motion in the alternating-gradient decelerator has been …
-
Experiments with Molecules on a Chip
… trap loss. At last, a new chip- based Stark decelerator is presented, which is a miniaturized version of the so-called “traveling-wave” ring decelerator. This chip-based decelerator should be able to trap more molecules compared to the chip that was used so far, and due to improved …