Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 14 of 14 for “"Defibrillation threshold."”
-
Sedation Strategies for Defibrillation Threshold Testing: Safety Outcomes with Anesthesiologist Compared to Proceduralist-Directed Sedation. An Analysis from the Shockless Implant Evaluation (SIMPLE) Study
… (ADS) versus sedation by proceduralist (PDS) for defibrillation threshold (DT) testing. We aimed to evaluate adverse events and safety outcomes with ADS versus PDS for DT testing. Methods: A post-hoc analysis of the Shockless Implant Evaluation (SIMPLE) study was performed among the 1242 patients …
-
Defibrillation, the coronary venous system and the passive electrode affect
… and future development of these devices is the defibrillation threshold (the amount of energy required to reliably terminate fibrillation). Changing the vectors of defibrillation through lead positioning has the potential to reduce defibrillation threshold. Current methods for the assessment of …
-
AMPLITUDE SPECTRUM AREA AS A PREDICTOR OF SUCCESSFUL DEFIBRILLATION: THRESHOLD VALUES ANALYSIS IN A LARGE DATABASE OF OUT-OF-HOSPITAL CARDIAC ARREST TREATED BY DC-SHOCK
La scelta del momento di procedure alla defibrillazione (DF) di un paziente in fibrillazione ventricolare (FV) comporta l’interruzione del massaggio cardiaco e, in caso di inefficacia, il rischio di aggiungere un ulteriore danno miocardico. Perciò è assai importante individuare un indicatore …
-
Atrial Arrhythmogenic Substrates: The Role of Structure and Molecular Remodeling
… explore the application of a novel low-voltage defibrillation therapy to a rabbit model of atrial tachyarrhythmias and show significant reductions in the defibrillation threshold for both AF and AFl. We utilize a variety of experimental techniques, such as high throughput quantitative PCR, …
-
Nanosecond Stimulation and Defibrillation of Langendorff-Perfused Rabbit Hearts
The search for novel defibrillation methodologies focuses on minimizing deposition of energy to the heart, as this is an indicator for side effects including pain and tissue death. In this work, we investigate the effect of reducing the duration of the applied shocks from low milliseconds to the …
-
Analysis of defibrillation efficacy and investigation of impedance cardiography with finite element models incorporating anisotropic myocardium
Increasing defibrillation efficacy by estimating and lowering the defibrillation threshold (DFT) is important in positioning implantable defibrillating electrodes. We analyzed the relation between the experimentally-measured DFTs and the myocardial voltage gradients (VGs) simulated by the 3D …
-
Studies on malignant ventricular tachyarrhythmias and their treatment with an implantable defibrillator
… se during maintained circulation. To study the defibrillation threshold (DFT) and efficacy of a new and thinner ICD lead (DSP) compared with the standard lead (C). To study the effects of pectoral or abdominal generator positioning on bidirectional and biphasic defibrillation. To study if the …
-
High Resolution Multi-parametric Diagnostics and Therapy of Atrial Fibrillation: Chasing Arrhythmia Vulnerabilities in the Spatial Domain
… becomes a significant concern for electrical defibrillation of AF due to the fact that a patient is conscious when experiencing the arrhythmia. Limiting the risk of myocardial injury is key for both forms of fibrillation. In this project we aim to address the limitations of current …
-
The Effect Of Right Ventricular Insertion Cooling On Wavebreak Initiation Following Defibrillation Shocks
Although strong defibrillation shocks can save patients from life-threating tachyarrhythmias, the function of the heart may be compromised. We found in an earlier study that the right ventricular insertion (RVI) is responsible for most of the initial propagation failure (wavebreak) that drives the …
-
Macroscopic anisotropy tissue modelling for three dimensional finite element analysis of internal myocardium defibrillation
… potentielle du seuil de défibrillation prédite (defibrillation threshold or DFT) par rapport au positionnement des électrodes, quel que soit le modèle utilisé. Il est à noter que dans certains cas les prévisions du modèle anisotrope peuvent être très similaires à celles du modèle isotrope …
-
The role of myocardial fibrosis and ventricular mechanical dyssynchrony in the pathogenesis and treatment of contractile myocardial dysfunction.
… fibrillation in patients undergoing routine defibrillation threshold testing following implantable cardioverter-defibrillator insertion. In this mechanistic study, the dependence of left atrial function on left ventricular function is demonstrated. This finding establishes the context for the …
-
Equine electrocardiography revisited : 12- lead recording, vectorcardiography and the power of machine intelligence
… with transvenous electrical cardioversion (TVEC) threshold (in Joules), number of shocks and cardioversion success rate in horses. This was done in 73 horses treated for atrial fibrillation by TVEC. The mean difference between RA-FR and AFR was -13 fibrillations per minute and there was a moderate …