Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 15 of 15 for “"Demand-Controlled Ventilation (DCV)"”
-
A Demand-Controlled Ventilation (DCV) Systems Approach Towards Energy-Efficient Management for Improved Indoor Air Quality (IAQ)
… for educational environments, as poor ventilation and inadequate air filtration have been linked to adverse health effects and reduced cognitive performance. In commercial spaces, insufficient IAQ can lead to occupants' discomfort, increased sick leave, and lower productivity, whereas …
-
Experimental and simulation study of demand controlled ventilation
… for a multizone building utilizing three ventilation control strategies. The three strategies are occupancy-based demand controlled ventilation (DCV), carbon-dioxide based DCV and constant ventilation. The study compares the building's energy consumption using the three methods for summer, …
-
Demand Controlled Ventilation: Use in Calgary and Impact of Sensor Location
Demand controlled ventilation (DCV) is used to reduce the amount of energy required to condition outdoor air introduced into a building based by monitoring occupancy. This thesis reports the hours DCV is used in an existing building in Calgary. Results showed DCV was used approximately 20% of …
-
Feed-Forward Neural Network (FFNN) Based Optimization Of Air Handling Units: A State-Of-The-Art Data-Driven Demand-Controlled Ventilation Strategy
Heating, ventilation and air conditioning systems (HVAC) are the single largest consumer of energy in commercial and residential sectors. Minimizing its energy consumption without compromising indoor air quality (IAQ) and thermal comfort would result in environmental and financial benefits. …
-
Comparison of the energy and economic feasibility of different building systems.
… Heat Pump (GSHP), Variable Air Volume (VAV) RTU, Demand Controlled Ventilation (DCV), and Natural Daylighting.</p> <p>Each system will be modeled in two different building types. The first being a standard 100 ft by 100 ft office building with a flat roof. The second building type will be two long …
-
Novel control of run-around heat recovery system: Evaluation of the novel control method’s performance through laboratory experiments
… them appropriate for complex and specialized ventilation scenarios. However, their efficient operation critically depends on the accurate control of the circulating liquid flow rate to achieve optimal heat recovery performance. Traditional control strategies regulate liquid flow based on …
-
Simulation-based study on CO2-based demand controlled ventilation strategies for multiple zone variable air volume systems
Demand-Controlled Ventilation (DCV) is a ventilation control strategy that provides automatic reduction of outdoor air intake below design rates when the actual occupancy of spaces served by the system is less than design occupancy. This research aimed to propose CO2 and occupancy sensor-based DCV …
-
Next-Generation Sequences of Operation for Occupant-Adaptive Building HVAC Systems
… to the way buildings are traditionally controlled. However, poor sequences of operation can degrade the benefits of OCC. An analysis of two buildings before and after the initial COVID-19 lockdown --- one with two control logic faults corrected and an occupancy-based ventilation OCC, and …
-
Demand Controlled Ventilation Energy Savings for Air Handling Units
Heat, cooling, and ventilation units are major energy consumers for commercial buildings, they can consume as much as 50% of the total annual power usage of a building. Coherent management of an air handling system’s energy is a key factor of reducing the energy costs and CO2 emissions that are …
-
Towards Net Zero Energy Performance of the Montpetit Hall Building
… solutions to balance primary energy demand and NPV. Results indicated that upgrading semi-exposed floors, roofs, and south- and east-facing glazing reduced heating demand by up to 19.4%, leading to overall energy savings of nearly 13%. Double-glazed, argon-filled windows provided the …
-
User-adaptive environment - Feasibility of sensors and applications for improving indoor energy efficiency, comfort and well-being
… including detecting the room occupancy level, demand-controlled ventilation (DCV), and escalator performance analysis, was further evaluated. In the area of individual indoor comfort, methods and applications for local control of audio environment were reviewed. A position-independent, …
-
Improving building energy efficiency through novel hybrid models and control approaches including a data center case study
… of buildings and controls. Data centers and demand controlled ventilation (DCV) are the focus because they represent both "multifunctional buildings" and general energy system controls. This dissertation makes the following seven original contributions: (1) The first systematic, complete case …
-
Performance evaluation of carbon-dioxide sensors used in building HVAC applications
… sensors are widely used as part of a demand controlled ventilation (DCV) system for buildings requiring mechanical ventilation, and their performance can significantly impact energy use in these systems. Therefore, a study was undertaken to test and evaluate the most commonly used …
-
Advanced demand-controlled ventilation strategies for ACMV systems
… presents a detailed investigation into the demand-controlled ventilation (DCV) for ACMV systems. Four advanced DCV strategies have been proposed to improve the ventilation control performance in terms of control accuracy, energy efficiency, and practicability. Several key research issues in …
-
Energy Optimization of Heating, Ventilation, and Air Conditioning Systems
… devices within a building, heating, ventilation, and air conditioning (HVAC) systems account for over 50% of the total energy consumed. This makes HVAC systems a source of preventable and unexplored energy waste that can be tackled by incorporating intelligent operations. Since its …