Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 26 for “"Densimeter"”.

  1. Design, Construction, and Calibration of a Vibrating Tube Densimeter for Volumetric Measurements of Acid Gas Fluids

    … processes. In this study, a vibrating tube densimeter was constructed and calibrated in order to perform volumetric measurements on acid gas fluids where previous literature were sparse. The densimeter uses an optically coupled feedback loop in order to maintain a fluid filled vibrating tube …

    calgary Repository record for Design, Construction, and Calibration of a Vibrating Tube Densimeter for Volumetric Measurements of Acid Gas Fluids (opens in a new tab)

  2. Design and Development of a High-Temperature High-Pressure Rolling Ball Viscometer/Densimeter and Evaluation of Star Polymer-Solvent Mixtures

    Modern automotive applications such as transmission clutch plates, combustion chambers, diesel fuel injector tips, and axle gears and friction plates operate at temperatures that can exceed 250°C and pressures of 40,000 psia. Industrial practice is to add homopolymers and copolymers to base oils to …

    vcu Repository record for Design and Development of a High-Temperature High-Pressure Rolling Ball Viscometer/Densimeter and Evaluation of Star Polymer-Solvent Mixtures (opens in a new tab)

  3. High-accuracy P-p-T measurements of pure gas and natural gas like mixtures using a compact magnetic suspension densimeter

    … compact single sinker magnetic suspension densimeter has been used first to determine densities of pure component’s densities for which very reliable data are available. After validating its performance, the densities of four light natural gas mixtures, containing no C6+ fraction and …

    tamu Repository record for High-accuracy P-p-T measurements of pure gas and natural gas like mixtures using a compact magnetic suspension densimeter (opens in a new tab)

  4. Magnetic densimeters: design and operation

    Presented here is a comparison of two magnetic densimeters, one using a r.f. sensing system and one using an optical sensing system. Both systems have the same control system. Based on a series of experiments, it appears that the optical sensing densimeter is much easier to handle than the one …

    vt Repository record for Magnetic densimeters: design and operation (opens in a new tab)

  5. Redesign of a High-Pressure, Single-Sinker Magnetic Suspension Densimeter to Measure Highly Accurate Densities for Fluids: Applications to Helium, Argon, and Helium + Methane Mixtures

    … range is a single sinker magnetic suspension densimeter (MSD). This work presents the redesign of the TAMU MSD. This apparatus is a unique MSD because its pressure measurement range extends to 200 MPa. A system redesign has enabled the apparatus to achieve a temperature range of 300 to 500 K. …

    tamu Repository record for Redesign of a High-Pressure, Single-Sinker Magnetic Suspension Densimeter to Measure Highly Accurate Densities for Fluids: Applications to Helium, Argon, and Helium + Methane Mixtures (opens in a new tab)

  6. Development of a sensor for the continuous measurement of oil concentration in a refrigeration system

    … oil concentration sensors: a vibrating U-tube densimeter, a new type of in-line viscometer, a prototype acoustic velocity probe, and an optical fiber refractometer;A flow loop capable of simulating a wide variety of liquid-line conditions was constructed for the testing and calibration of the …

    iastate Repository record for Development of a sensor for the continuous measurement of oil concentration in a refrigeration system (opens in a new tab)

  7. High accuracy p-rho-t measurements up to 200 MPa between 200 K and 500 K using a compact single sinker magnetic suspension densimeter for pure and natural gas like mixtures

    … compact single sinker magnetic suspension densimeter has been used for density measurements. First, the densimeter is calibrated against pure component densities for which very reliable data are available. After validating its performance, the densities of four light natural gas mixtures …

    tamu Repository record for High accuracy p-rho-t measurements up to 200 MPa between 200 K and 500 K using a compact single sinker magnetic suspension densimeter for pure and natural gas like mixtures (opens in a new tab)

  8. Centrifugation Cushion vs. Spermfilter™: Effects On % Recovery

    … or centrifugation was measured using a densimeter device (ARS, Chino, CA). In addition, following all procedures, the sperm pellet was resuspended with the same solution and again subjected to analysis for concentration with the Densimeter to determine the % of spermatozoa recovered. …

    mo-state Repository record for Centrifugation Cushion vs. Spermfilter™: Effects On % Recovery (opens in a new tab)

  9. Modeling and Experimental Measurements of Thermodynamic Properties of Natural Gas Mixtures and Their Components

    … a detailed description of a vibrating tube densimeter, which is an alternative technique for measurement of p-ρ-T data in gases at critical conditions. This apparatus can measure fluids in a temperature range of 300 K to 470 K and pressures up to 140 MPa. This work calibrates the vibrating …

    tamu Repository record for Modeling and Experimental Measurements of Thermodynamic Properties of Natural Gas Mixtures and Their Components (opens in a new tab)

  10. Validation of a comercially available fluorescence-based instrument to evaluate stallion spermatozoal concentration and comparison to photometric systems

    … were analyzed with the NucleoCounter, the Densimeter, the Spermacue, flow cytometric and hemacytometric methods. Results were compared statistically by: 1) regression analysis, 2) the agreement of two instruments, whereby the difference in values between two instruments was plotted on the …

    tamu Repository record for Validation of a comercially available fluorescence-based instrument to evaluate stallion spermatozoal concentration and comparison to photometric systems (opens in a new tab)

  11. Equilíbrio de fases e comportamento volumétrico de sistemas aquosos contendo CO2, monoetileno glicol e NaCl nas condições de explotação de gás natural

    … the interconnections between an Anton Paar 4200M densimeter, a syringe pump and thermostatic baths with two types of pressure vessels: the Parr reactor 4561 and a variable volume equilibrium cell. The density points obtained with the experimental apparatus were validated with data and models from …

    brazil-ufrn Repository record for Equilíbrio de fases e comportamento volumétrico de sistemas aquosos contendo CO2, monoetileno glicol e NaCl nas condições de explotação de gás natural (opens in a new tab)

  12. Experimental determination of the volumetric properties for the system CO₂-CH₄-N₂ at 100-1000 bars and 50-300°C

    … 100-1000 bars, 50-300°C, using a vibrating-tube densimeter constructed at the Oak Ridge National Laboratory. An isobaric, isothermal flow-through method was employed to obtain a statistically significant number of measurements for the period of vibration at each set of P-T-X conditions. During …

    vt Repository record for Experimental determination of the volumetric properties for the system CO₂-CH₄-N₂ at 100-1000 bars and 50-300°C (opens in a new tab)

  13. Vapor–Liquid Equilibrium and Excess Enthalpies: Measurements and Modeling for Process Industry

    … and an Anton Paar DMA 512P vibrating tube densimeter for excess volumes (VE). The parallel use of different VLE apparatuses widened the scope of the experiments and ensured the high quality of the VLE data. The studied binary systems consisted of a group of alcohols with alkanes, ethers, …

    aalto Repository record for Vapor–Liquid Equilibrium and Excess Enthalpies: Measurements and Modeling for Process Industry (opens in a new tab)

  14. Geochemistry of fluid-rock processes

    … Chapter III "Reassessment of the Raman CO2 densimeter", details new developments in the use of the Raman spectroscopy to characterize the density of CO2. In this chapter we describe briefly the Raman effect of CO2 and the density dependence of the Fermi diad using different Raman …

    vt Repository record for Geochemistry of fluid-rock processes (opens in a new tab)

  15. Thermodynamic investigations of some aqueous solutions through calorimetry and densimetry

    … high temperature and pressure vibrating tube densimeter. These data have been used to test the utility of an automated high temperature and pressure densimetric data analysis program. Apparent molar volumes and heat capacities of several aqueous rare earth sulphate systems at 298.15 K and 0.10 …

    lethbridge Repository record for Thermodynamic investigations of some aqueous solutions through calorimetry and densimetry (opens in a new tab)

  16. Accurate Measurements and Modeling of the PpT Behavior of Pure Substances and Natural Gas-Like Hydrocarbon Mixtures

    … high-pressure, single-sinker magnetic suspension densimeter is used to perform density measurements over a wide range of temperatures and pressures. This work contains data on nitrogen, carbon dioxide, and a typical residual gas mixture (95% methane, 4% ethane, and 1% propane). Experimental …

    tamu Repository record for Accurate Measurements and Modeling of the PpT Behavior of Pure Substances and Natural Gas-Like Hydrocarbon Mixtures (opens in a new tab)

  17. Experimental Characterization and Molecular Study of Natural Gas Mixtures

    … high pressure single sinker magnetic suspension densimeter. An entire uncertainty analysis of this apparatus reveals that the uncertainty of the density data is less that 0.05% across the entire ranges of temperature (200 to 500) K and pressure (up to 200 MPa). These characteristics make the PpT …

    tamu Repository record for Experimental Characterization and Molecular Study of Natural Gas Mixtures (opens in a new tab)

  18. Dew-Point Density Measurements of Gas Mixtures with Low Uncertainty

    … dew-point density measurements, the Four-Sinker Densimeter (FSD), was designed by Moritz et al. (2017). This instrument simultaneously determines fluid density and adsorption loads, partially correcting the distorting effects. Achieving low uncertainties requires accurate calibrations and precise …

    qucosa-diss

  19. Combustibles ambientalmente sostenibles: caracterización termofísica de biogasolinas y biodieseles formulados a partir de biobutanol

    … techniques used were a vibrating tube automated densimeter to measure the densities with an uncertainty of ± 0.2% at temperatures up to 423 K and pressures up to 140 MPa, and an original automated flow calorimeter to accurately measure isobaric heat capacities in the temperature range from 273 K …

    valladolid Repository record for Combustibles ambientalmente sostenibles: caracterización termofísica de biogasolinas y biodieseles formulados a partir de biobutanol (opens in a new tab)

Page 1 of 2