Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 81 for “"Deoxyhemoglobin"”
-
MR Perfusion Imaging of the Human Brain With Deoxyhemoglobin Contrast
… which in turn yields a change in paramagnetic deoxyhemoglobin (dOHb). In both cases, T2*-weighted signal changes are exploited for the purposes of characterizing perfusion physiology. The reliance on invasive contrast in DSC-MRI is a notable limitation to current state-of-the-art perfusion …
-
HYPOXIA-INDUCED DEOXYHEMOGLOBIN; A CONTRAST AGENT FOR CEREBRAL PERFUSION IMAGING
… a novel intrinsic MRI contrast agent, changes in deoxyhemoglobin concentration ([dOHb]), for assessing resting cerebral perfusion as a diagnostic metric in clinical decision making. Indeed, a bolus change in [dOHb], similar to that produced by an intravenous injection of GBCA, was achieved by …
-
The Cerebral Venous Network: deoxyhemoglobin as contrast, bias and quantitative biomarker in magnetic resonance imaging
… and brain function in health and disease. The deoxyhemoglobin (dHb) in veins provides an important source of contrast for Magnetic Resonance Imaging (MRI). It can be used non-quantitatively via the Blood Oxygen-Level Dependent (BOLD) signal, or it can be used to extract quantitative biomarkers. …
-
Methemoglobin Formation via Nitric Oxide and Comparison of Methemoglobin, Deoxyhemoglobin, and Ferrous Nitrosyl Hemoglobin as Potential MRI Contrast Agents
Gadolinium-based contrast agents (GBCAs) are in widespread use to enhance magnetic resonance angiography images for evaluating vascular pathology. However, there are safety concerns and limitations regarding the use of GBCAs. It has been shown that the magnetic resonance imaging (MRI) signal …
-
Design of a fiber optic oxygen sensor based on immobilized hemoglobin
… sensor consists of a thin layer of immobilized deoxyhemoglobin at the common end of a bifurcated fiber. Immobilization is done using the alginate gel procedure. The immobilized reagent is separated from the standard oxygen sample by the gel with or without semi-permeable membrane, and the entire …
-
Exploring Functional Connectivity Among Adults with Persistent Post-Concussion Syndrome Using Functional Near Infrared Spectroscopy
… differences in the absorption of local oxy- and deoxyhemoglobin in the brain. The changes in cerebral tissue oxygenation are then used to monitor brain activity. fNIRS has demonstrated comparability to fMRI for reliably detecting changes in cerebral vascular reactivity and may provide insight …
-
Interrogating Tissue Perfusion And Oxygenation Using Dynamic Magnetic Resonance Imaging And Quantitative Susceptibility Mapping
… Blood oxygenation is determined by the amount of deoxyhemoglobin in red blood cell. Magnetic susceptibility of deoxyhemoglobin is a source of MR contrast for imaging oxygenation. This dissertation reports correction schemes in both data acquisition and image reconstruction of QSM for improved …
-
Effects of brief aquatic exercise in multiple sclerosis on mobility and function
… exercise intervention on cerebral oxyhemoglobin, deoxyhemoglobin, and % tissue saturation index (%TSI). METHODS: Twenty-one individuals diagnosed with multiple sclerosis were assigned to the exercise group or the non-exercise group. Both groups participated in a pretest and post-test separated by …
-
Investigating the magnetic susceptibility contributions of hypoxia and myelin in the mouse brain using quantitative MRI
… the brain that correlated with elevated deoxyhemoglobin levels, highlighting R2* as a promising marker for brain oxygenation. Magnetic susceptibility changes were primarily localized to venous structures, underscoring its spatial specificity to paramagnetic compounds. For …
-
Development and Application of Magnetic Resonance Imaging Techniques for the Study of Exercise-Induced Angiogenesis in the Rat Brain
… period. We have looked at changes in the local deoxyhemoglobin concentrations using T2*-weighted imaging, changes in blood flow, and changes in blood volume occurring as a result of this period of exercise. Based on these experiments, we have found that exercised animals have a greater …
-
Frequency Domain Near-Infrared Spectroscopy of The Uterine Cervix During Cervical Ripening
… using the t-test were calculated for oxy- and deoxyhemoglobin, total hemoglobin, oxygen-saturation, and water. The wavelength-dependent decrease of scattering (scatter power) was calculated by an exponential fit and tested with the Wilcoxon test. Results: Misoprostol induced a decrease in total …
-
Acute physiological responses to arm-cranking with blood flow restriction
… RER, ventilation), metabolic (tissue saturation, deoxyhemoglobin concentrations), and perceptual (effort, pain) responses to arm cranking with BFR at varying arterial occlusion pressures (AOP). Ten adults performed 4 intermittent arm cranking protocols (6x2-min, 1-min recovery): 1) low load (LL) – …
-
Asssessment of Tissue Viability in Acute Thermal Injuries Using Near Infrared Point Spectroscopy
… burn depth increased. The proportion of oxy- and deoxyhemoglobin to total hemoglobin showed that the ratio of oxy- to deoxyhemoglobin decreased as burn injury increased. Methemoglobin levels as a ratio of total hemoglobin also showed that as the severity of injury increased the proportion of …
-
Multi-distance and multi-frequency frequency-domain near-infrared spectroscopy - characterization and application
… of tissue and the concentration of oxy and deoxyhemoglobin, water and fat. Near-infrared spectroscopy and imaging offer the possibility to non-invasively measure hemodynamic responses of the brain to external stimuli. The ability of near-infrared spectroscopy and imaging to measure all these …
-
Photoacoustic imaging for physiological biomarkers of intestinal health in infants and children
… imaging (PAI) noninvasively measures oxy/deoxyhemoglobin, visualizes intestinal oxygenation and perfusion, and is promising for improved NEC detection to create better outcomes for patients. Methods: Under Wake Forest IRB approval, eighteen healthy pediatric participants aged …
-
Characterizing Susceptibility Weighted MRI in the Experimental Autoimmune Encephalomyelitis Mouse Model of Multiple Sclerosis
… where most of these lesions were attributed to deoxyhemoglobin and a smaller number were due to parenchymal iron deposition. Next, we validated a method to identify deoxyhemoglobin-based SWI hypointensities in vivo which entailed combining SWI with hyperoxygenation. Following this, we sought to …
-
Spatiotemporal Dynamics of Tissue Oxygenation in Awake, Behaving Mice
… robust biphasic changes in oxyhemoglobin, deoxyhemoglobin and vascular cell intracellular [Ca2+] in response to prolonged whisker stimulation. The magnitude and kinetics of these changes were related to the cerebrovascular segment within the cranial window. Unlike the early component …
-
Quantitative lactate-specific magnetic resonance imaging and proton spectroscopy of muscle and brain
… states, of local blood flow, blood volume, and deoxyhemoglobin concentration, which change the apparent NMR relaxation times T$\sb1$ and T$\sb2$ of water around the area of activation.
-
MOLECULAR AND PHYSIOLOGICAL RESPONSES TO HYPOXIA
… the high-altitude Oromo suffered a much higher deoxyhemoglobin level. In conclusion, high-altitude Amhara offset a dampened hemoglobin response with the vasodilatory nitric oxide, whereas the Oromo mount a bigger hemoglobin response at the cost of circulating deoxyhemoglobin.
-
MAGNETIC SUSCEPTIBILITY APPROACH FOR QUANTITATIVE CEREBRAL OXYGEN METABOLISM MAPPING
… induced by blood iron molecules such as deoxyhemoglobin, methemoglobin, and hemosiderin, providing opportunities to identify and quantify these molecules and oxygen consumption, especially in brain. This dissertation reports: 1) a clinical study on intracranial hematoma evolution using …
Page 1 of 5