Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 53 for “"Desorber"”.

  1. EXPERIMENTAL PERFORMANCE EVALUATION OF DESORBER IN A HYBRID ABSORPTION VAPOR COMPRESSION SYSTEM

    … the performance of a 3 kW mini-channel desorber using an R134a/POE32 solution mixture. The facility was fabricated to simulate a hybrid absorption/vapor compression system for an off-grid high temperature application utilizing an air-cooled absorber. Desorber design replicated the …

    maryland Repository record for EXPERIMENTAL PERFORMANCE EVALUATION OF DESORBER IN A HYBRID ABSORPTION VAPOR COMPRESSION SYSTEM (opens in a new tab)

  2. Development of a System of MEA Solutions Activated by Novel Poyamines for Natural Gas Sweetening Mass Transfer in Absorber and Desorber Columns

    … the mass transfer of CO2 in absorber and in desorber respectively. In both trends of KGav and KLav, PEI-B blends were recorded the best followed by TEPA blends and then PZ blends while non-activated MDEA gave the lowest mass transfer coefficients. Two models were applied for KLav and for KGav …

    regina Repository record for Development of a System of MEA Solutions Activated by Novel Poyamines for Natural Gas Sweetening Mass Transfer in Absorber and Desorber Columns (opens in a new tab) Download PDF for Development of a System of MEA Solutions Activated by Novel Poyamines for Natural Gas Sweetening Mass Transfer in Absorber and Desorber Columns (opens in a new tab)

  3. ADVANCED ABSORPTION MATERIALS AND THEIR APPLICATION IN REFRIGERATION

    … chiller consisting of an electrostatic desorber, a nozzle-based absorber, and an evaporator. Due to the tiny droplet size, it is thermodynamically challenging to regenerate the absorbed water in a liquid form from a microemulsion state. The electrostatic desorber would first utilize heat …

    maryland Repository record for ADVANCED ABSORPTION MATERIALS AND THEIR APPLICATION IN REFRIGERATION (opens in a new tab)

  4. Experimental and Analytical Investigation of Ammonia-Water Desorption in Microchannel Geometries

    … analytical study of a microchannel ammonia-water desorber was conducted in this study. The desorber consists of 5 passes of 16 tube rows each with 27, 1.575 mm outside diameter x 140 mm long tubes per row for a total of 2160 tubes. The desorber is an extremely compact 178 mm x 178 mm x 0.508 m …

    gatech Repository record for Experimental and Analytical Investigation of Ammonia-Water Desorption in Microchannel Geometries (opens in a new tab)

  5. Desorption of ammonia-water mixtures in microscale geometries for miniaturized absorption systems

    … vapor generation units, comprising integrated desorber, analyzer, and rectifier segments that use microchannel geometries, were conceptualized. The branched-tray concept features a desorber segment that uses predominantly pool-boiling mechanisms for desorption, while the vertical column …

    gatech Repository record for Desorption of ammonia-water mixtures in microscale geometries for miniaturized absorption systems (opens in a new tab)

  6. Coupling of a solid oxide fuel cell with a vapour absorption refrigeration system for refrigerated truck application

    … pipes has been explored for the first time in a desorber and hence that presents the biggest novelty of this work. Design and modelling of all the components in the VARS is a major project in itself hence in this thesis only the desorber of the VARS was designed and modelled. Two different …

    birmingham Download PDF for Coupling of a solid oxide fuel cell with a vapour absorption refrigeration system for refrigerated truck application (opens in a new tab)

  7. Thermal treatment of organic contaminated solids and waste : experiment, model and mass balance

    … energy requirements in the bench scale thermal desorber. However, only 6 percent of total energy requirement is due to this heat loss to environment in a full scale desorber. The major heat required in a full scale desorber is used for treatment of water which consumes approximately 48 percent …

    njit Repository record for Thermal treatment of organic contaminated solids and waste : experiment, model and mass balance (opens in a new tab)

  8. Ammonia - water desorption in flooded columns

    … be separated through selective boiling in the desorber. Desorbers with counter-current flow of the solution and generated vapor enable efficient heat and mass transfer between the two phases, reducing the absorbent content in the generated vapor. Flow visualization experiments at temperatures, …

    gatech Repository record for Ammonia - water desorption in flooded columns (opens in a new tab)

  9. A Comprehensive Evaluation of Off-Gas Emissions From A Catalyst-Aided, Amine-Based, Post Combustion Capture of CO2 From Industrial Exhaust Gas Streams

    … absorber catalyst (APC) and one solid acid desorber catalyst, a proprietary desorber catalyst (DPC). The screening results for the absorber catalysts showed that the equilibrium loading, and initial absorption rate were enhanced by 5.6% and 33.3 % respectively for ACS and by 3.9% and 29.4% …

    regina Repository record for A Comprehensive Evaluation of Off-Gas Emissions From A Catalyst-Aided, Amine-Based, Post Combustion Capture of CO2 From Industrial Exhaust Gas Streams (opens in a new tab) Download PDF for A Comprehensive Evaluation of Off-Gas Emissions From A Catalyst-Aided, Amine-Based, Post Combustion Capture of CO2 From Industrial Exhaust Gas Streams (opens in a new tab)

  10. Estimation of desorbed compositions with variable-temperature stepwise desorption

    … on molecular sieves, 13X. A differential thermal desorber was modified and was used to determine the rates and apparent equilibrium of propane-propylene mixtures adsorbing and desorbing on molecular sieves. A computer algorithm was developed to predict VTSD results from desorption equilibrium …

    must-thes Repository record for Estimation of desorbed compositions with variable-temperature stepwise desorption (opens in a new tab)

  11. Dynamic model for small-capacity ammonia-water absorption chiller

    … transient events. A counterflow falling film desorber model is employed to account for the heat and mass transfer interactions between the liquid and vapor phases, inside the desorber. The liquid film flows down counter to the rising vapor, thereby exchanging heat with the counterflowing …

    gatech Repository record for Dynamic model for small-capacity ammonia-water absorption chiller (opens in a new tab)

  12. Organics in ambient air by collection on tenax, thermal desorption,and capillary chromatography with parallel FID/ECD analysis

    … analyzed by using a Tekmar Automatic Thermal Desorber and capillary GC system with parallel flame ionization (FID) and electron capture detectors (ECD). A series of quality assurance procedures has been established to improve and assure the accuracy and precision of sample collector and …

    njit Repository record for Organics in ambient air by collection on tenax, thermal desorption,and capillary chromatography with parallel FID/ECD analysis (opens in a new tab)

  13. Thermally activated miniaturized cooling system

    … of heat sink temperatures (20 ≤ T ≤ 35°C) and desorber thermal input rates (500 ≤ Q ≤ 800 W). Evaporator coolant heat duties in the study ranged from 136 to 300 W, while system COPs ranged from 0.247 to 0.434. At a nominal rating condition of 35°C heat sink temperature, the maximum thermal …

    gatech Repository record for Thermally activated miniaturized cooling system (opens in a new tab)

  14. Transient simulation of ammonia-water mixture desorption for absorption heat pumps & optimal control of an electric vehicle cabin air conditioning system

    … to simulate the transient response of a desorber for small-capacity ammonia-water absorption heat pumps. The model is based on dynamic analysis of conservation equations and accounts for the thermal capacitances in the heat exchanger wall material and fluid volumes. The numerical solver …

    gatech Repository record for Transient simulation of ammonia-water mixture desorption for absorption heat pumps & optimal control of an electric vehicle cabin air conditioning system (opens in a new tab)

  15. Investigation of fouling mechanisms to guide the design of diesel engine exhaust driven absorption heat pumps

    … results are used to design an exhaust-coupled desorber of a 2.71 kW cooling capacity waste-heat driven ammonia-water absorption heat pump while accounting for the degradation due to fouling. The findings from this work can guide the design of a variety of waste heat recovery systems in …

    gatech Repository record for Investigation of fouling mechanisms to guide the design of diesel engine exhaust driven absorption heat pumps (opens in a new tab)

  16. Thermal degradation of PZ-promoted tertiary amines for CO2 capture

    … stable solvents and can be regenerated in the desorber between 120 and 130 °C. PZ-promoted tertiary amine solvents with no methyl groups, such as ethyldiethanolamine (EDEA), were found to have an intermediate stability and can be regenerated in the desorber between 130 and 140 °C. PZ-promoted …

    texas Repository record for Thermal degradation of PZ-promoted tertiary amines for CO2 capture (opens in a new tab)

  17. Explosive vapor detection technology in the atmosphere at concentrations of parts per quadrillion and below

    … filtro de movilidad. El DMA-SESI se acopla a un desorber multitemperatura y a un espectrómetro de masas de triple cuadrupolo para el análisis de trazas de vapores de explosivo, permitiendo detectar explosivos en concentraciones sin precedentes de 0.01 ppq (parts per cuadrillion = 10-15 …

    valladolid Repository record for Explosive vapor detection technology in the atmosphere at concentrations of parts per quadrillion and below (opens in a new tab)

Page 1 of 3